PHOTOMETRICS |
|
|
|
| 2AC | |
|
| Candlepower |
|
| ||
| Electronic Ballast |
|
|
|
| |
| (2) F32T8/835 Lamps | Angle | Along II | 45° | Across | |
| 3100 Lumens each | 0 | 1613 | 1613 | 1613 | |
| 5 | 1605 | 1610 | 1616 | ||
| Spacing criterion: | |||||
| 10 | 1585 | 1594 | 1604 | ||
| (II) 1.3 x mounting | 15 | 1550 | 1568 | 1585 | |
| height, ( ) 1.5 x | 20 | 1501 | 1530 | 1557 | |
| 25 | 1439 | 1482 | 1520 | ||
| mounting height | |||||
| 30 | 1365 | 1424 | 1476 | ||
|
| |||||
Efficiency 84.9% | 35 | 1279 | 1357 | 1424 | ||
Test Report: | 40 | 1183 | 1281 | 1365 | ||
| ||||||
| 45 | 1079 | 1197 | 1297 | ||
| ||||||
| 50 | 966 | 1106 | 1220 | ||
| EB81.IES | 55 | 847 | 1006 | 1133 | |
| LER = FL80 LPW | 60 | 722 | 898 | 1021 | |
| 65 | 589 | 782 | 856 | ||
| Yearly Cost of 1000 | |||||
| 70 | 452 | 634 | 663 | ||
| lumens, 3000 hrs at | 75 | 315 | 456 | 465 | |
| .08 KWH = $2.90 | 80 | 187 | 280 | 277 | |
| 85 | 81 | 118 | 113 | ||
|
| |||||
|
| 90 | 0 | 0 | 0 |
C o effi c i e n t s of Utilization
|
| Effective floor cavity reflectance |
| 20% |
|
|
|
|
|
|
|
|
|
| ||||||
rc |
|
| 80% |
|
| 70% |
|
| 50% |
|
| 30% |
|
| 10% |
| 0% |
| ||
rw |
| 70 | 50 | 30 | 10 | 70 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 |
|
RCR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
| 101 | 101 | 101 | 101 | 99 | 99 | 99 | 99 | 94 | 94 | 94 | 90 | 90 | 90 | 87 | 87 | 87 | 85 |
|
1 |
| 92 | 87 | 83 | 80 | 89 | 85 | 82 | 79 | 82 | 79 | 76 | 78 | 76 | 74 | 75 | 73 | 72 | 70 |
|
2 |
| 83 | 75 | 69 | 64 | 81 | 74 | 68 | 63 | 71 | 66 | 62 | 68 | 64 | 60 | 65 | 62 | 59 | 57 |
|
3 |
| 75 | 66 | 58 | 53 | 73 | 64 | 57 | 52 | 62 | 56 | 51 | 59 | 54 | 50 | 57 | 53 | 49 | 47 |
|
4 |
| 69 | 58 | 50 | 44 | 66 | 57 | 49 | 44 | 54 | 48 | 43 | 52 | 47 | 42 | 51 | 46 | 42 | 40 |
|
5 |
| 63 | 51 | 43 | 38 | 61 | 50 | 43 | 37 | 49 | 42 | 37 | 47 | 41 | 36 | 45 | 40 | 36 | 34 |
|
6 |
| 58 | 46 | 38 | 33 | 56 | 45 | 38 | 32 | 44 | 37 | 32 | 42 | 36 | 32 | 41 | 36 | 31 | 30 |
|
7 |
| 54 | 42 | 34 | 29 | 52 | 41 | 34 | 28 | 40 | 33 | 28 | 38 | 32 | 28 | 37 | 32 | 28 | 26 |
|
8 |
| 50 | 38 | 30 | 25 | 48 | 37 | 30 | 25 | 36 | 30 | 25 | 35 | 29 | 25 | 34 | 29 | 25 | 23 |
|
9 |
| 46 | 35 | 28 | 23 | 45 | 34 | 27 | 23 | 33 | 27 | 22 | 32 | 26 | 22 | 31 | 26 | 22 | 21 |
|
10 |
| 44 | 32 | 25 | 20 | 42 | 32 | 25 | 20 | 31 | 25 | 20 | 30 | 24 | 20 | 29 | 24 | 20 | 19 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Zonal Lumen Summary
Zone | Lumens | %Lamp | %Fixture |
1279 | 20.6 | 24.3 | |
2127 | 34.3 | 40.4 | |
3942 | 63.6 | 74.9 | |
5266 | 84.9 | 100.0 | |
5266 | 84.9 | 100.0 |
Luminance Data
| Average | Average | Average |
Angle | |||
in Deg | cd/sm | cd/sm | cd/sm |
45 | 2186 | 2425 | 2628 |
55 | 2115 | 2513 | 2830 |
65 | 1996 | 2651 | 2902 |
75 | 1743 | 2524 | 2574 |
85 | 1331 | 1939 | 1857 |
ORDERING INFORMATION
S A M P L E NUMBER: 2AC - 232 - UNV- L8841 - EB82 - U
Rating
Blank=
Standard
NY=NewYork
Rated
ATW-SW4=
Chicago
Rated
Width
2=2' Width
Series
AC=Accord Series
Number of Lamps
(Not included)
2=2 Lamp
Wattage (Length)
32=32W T8 (48")
Shielding
Blank=Frosted Acrylic SQP=Lens with Square Pattern Insert RDP=Lens with Round Pattern Insert
Voltage(1)
UNV=Universal
Voltage
Options
GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed EL=Emergency Installed
Lamps
L8835=T8 Lamp, 17W and 32W, 3500K L8841=T8 Lamp, 17W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens
BallastType
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast 1 or 2
EB8 /PLUS=T8 Electronic Instant Start.
|
|
|
| High Ballast Factor >1.13.Total | |
No. of | Harmonic Distortion < 20% | ||||
Ballast | |||||
| |||||
1 or 2 |
|
ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%
No. of Ballast 1 or 2
HPT8 Ballast
Ballast
Packaging
U=Unit Pack PALC=Job Pack, in carton
Type
A=Air (optional)
HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77
HB8 =T8 Electronic Instant Start. Ballast Factor .88
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. High Ballast Factor
NOTES: (1) Products also available in
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
HR8_DI M=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start. High Ballast Factor
| SHIPPING INFORMATION | |||||
|
|
|
|
|
|
|
| Catalog No. | Wt. | ||||
|
|
| 28 lbs. |
| ||
|
|
|
|
| ||
Specifications and Dimensions subject to change without notice. | ADF080359 | |||||
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 | 08/26/2008 2:48:16 PM |