Catalog #

Project

Comments

Prepared by

Type

Date

SPECIFICATION FEATURES
07/08/2008 2:19:55 PM
Consult your representative for additional options and finishes.
ADF051819
CEILING COMPATIBILITY
DOOR FRAMES
MOUNTING DATA
LAMP CONFIGURATIONS
DESCRIPTION
Cooper Lighting introduces accord II(TM), a new recessed T5 or T8 fixture.
The accord II(TM) redefines fluorescent lighting by providing aesthetics,
comfort and energy savings. The accord II(TM) provides increased comfort
levels while providing significant energy savings.
The accord II(TM) is the ideal solution for offices, schools, hospitals, retail
and other applications.
A ... Construction
Shallow 3-3/4" deep housing is die
formed of code gauge, prime cold
rolled steel. Integral end plates are
securely attached for strength and
rigidity and the elimination of
gaps. Four auxiliary fixture end
suspension points are provided.
KOs for continuous row wiring.
Large access plate for supply
connection.
B ... Electrical*
Ballasts are Class "P" and are
positively secured. Rotor-lock
lampholders ensure positive lamp
retention. UL/CUL listed. Suitable
for damp locations.
C ... Ballast Access
Ballast can be removed from
below without tools.
D ... Finish
Durable cold rolled steel with
multistage, iron phosphate
pretreatment and white enamel
finish to ensure maximum bonding
and rust inhibition.
E ... Reflectors
Reflector has high reflectance
baked white enamel finish for
luminous uniformity.
F ... Shielding
Positively retained frosted acrylic
lenses and baffle provide a soft but
effective distribution of light.
Spring loaded latch and T-hinge
doorframe for ease of installation
and maintenance.

2AC2

228T5

254T5

232T8

T5 OR T8 LAMPS
2' X 4' Recessed
Troffer Series
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
C
ModularTr i m
With Support i n
g
Swing Gates
C e i l i n
gTri m
Ty p e Ty p e
Exposed Grid G
ConcealedT G
SlotGrid G
F l a n g
e F
MetalPa n C
(
Verify compatibility/ consult
f a c t o r y. )
G
G r i d / L a y- i n
S t a n d a r
d
G
ConcealedT
G
Slot Grid
F
FlangeTr i m
WithSupport i n g
SwingGates
GC8
Flat, White
Steel
EBBallast & STD Lamps @ 277V
228T5(58)
232(58)
254T5(106)
LuminaireEfficacy Rating
LER=FL67
CatalogNumber: 2AC2-228T5-PBW
YearlyCostof 1000 lumens,
3000hrs at .08 KWH = $3.59
*Referencethe lamp/ballast data in the
TechnicalSectionfor specific lamp/ballast
requirements.
**ConsultPre SalesTechnicalSupport.
* * * See Drywall Frame Kit Accessory
E N E RGY D ATA
InputWatts:
A BC D FE
COOPER LIGHTING - METALUX®