Cooper Lighting Photometrics, 2RDI-224T5RPD, 2RDI-324T5RPD, Ordering Information, Accessories

Models: 124T5HO 224T5HO 2RDI 314T5 324T5HO

1 2
Download 2 pages 54.16 Kb
Page 2
Image 2
PHOTOMETRICS

PHOTOMETRICS

2RDI

 

 

2RDI-224T5RPD

Electronic Ballast

(2) F24T5HO/830 Lamps

1750 Lumens

C a n d e l a

 

 

 

2RDI-324T5RPD

 

 

 

 

Electronic Ballast

Angle

Along II

45o

Across

(2) F24T5HO/830

 

0

631

631

631

 

lamps

5

630

630

629

 

 

1750 lumens

10

622

623

625

 

C a n d e l a

Angle

Along II

45o

Across

0

1001

1001

1001

5

1002

998

996

10

989

988

988

Spacing criterion: (II) 1.3 x mounting height, () 1.3 x mounting height

Efficiency 61.7%

Test Report: 2RDI224T5RPD.IES

LER = FL39

Yearly Cost of 1000 lumens, 3000 hrs at

.08 KWH = $6.11

15

608

612

616

 

Spacing criterion:

20

588

596

604

 

(II) 1.3 x mounting

25

563

576

589

 

 

height, () 1.3 x

30

533

553

570

 

 

mounting height

35

497

525

549

40

457

494

524

Efficiency 63.9%

45

412

460

496

 

 

Test Report:

50

364

424

466

 

55

312

385

433

 

2RDI324T5RPD.IES

60

257

344

398

 

LER = FL42

65

202

302

360

 

 

Yearly Cost of 1000

70

150

259

318

 

75

105

215

280

 

lumens, 3000 hrs at

80

65

175

242

 

.08 KWH = $5.72

85

32

134

197

 

 

 

90

0

0

0

 

 

15

967

969

974

20

935

943

953

25

894

910

926

30

847

871

894

35

789

825

858

40

724

774

816

45

652

717

770

50

575

658

722

55

491

596

669

60

403

531

611

65

314

463

549

70

230

394

482

75

159

325

417

80

97

257

354

85

48

197

291

90

0

0

0

C o e f f i c i e n t s o f U t i l i z a t i o n

 

Effective floor cavity reflectance

20%

 

 

 

 

 

 

 

 

 

rc

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

rw

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

74

74

74

74

72

72

72

72

69

69

69

66

66

66

63

63

63

62

1

66

62

59

56

64

61

58

55

58

55

53

55

53

52

53

52

50

49

2

59

53

48

44

57

52

48

44

50

46

43

48

45

42

46

43

41

39

3

54

46

41

36

52

45

40

36

43

39

35

42

38

35

40

37

34

33

4

49

41

35

30

47

40

34

30

38

33

30

37

33

29

35

32

29

27

5

45

36

30

26

43

36

30

26

34

29

25

33

29

25

32

28

25

23

6

41

33

27

22

40

32

26

22

31

26

22

30

25

22

29

25

22

20

7

38

29

24

20

37

29

23

20

28

23

19

27

23

19

26

22

19

18

8

36

27

21

18

35

26

21

17

26

21

17

25

20

17

24

20

17

16

9

33

25

19

16

32

24

19

16

23

19

16

23

19

15

22

18

15

14

10

31

23

18

14

30

22

17

14

22

17

14

21

17

14

21

17

14

13

Z o n a l L u m e n S u m m a r y

Ty p i c a l V C P P e r c e n t a g e s

 

 

 

 

 

 

 

 

Height Along

Height Across

Zone

Lumens

%Lamp

%Fixture

Room Size (Ft.)

8.5'

10.0'

8.5'

10.0'

0-30

499

14.3

23.1

 

20 x 20

67

75

60

69

0-40

827

23.6

38.3

 

30 x 30

61

66

52

58

0-60

1519

43.4

70.3

 

30 x 60

57

60

41

46

0-90

2160

61.7

100.0

 

60 x 30

61

65

56

62

0-180

2160

61.7

100.0

 

60 x 60

55

58

44

48

C o e f f i c i e n t s o f U t i l i z a t i o n

 

Effective floor cavity reflectance

20%

 

 

 

 

 

 

 

 

 

rc

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

rw

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

76

76

76

76

74

74

74

74

71

71

71

68

68

68

65

65

65

64

1

68

64

61

58

66

63

60

57

60

58

55

58

55

54

55

54

52

51

2

61

55

50

46

60

54

50

46

52

48

45

50

46

44

48

45

43

41

3

56

48

42

38

54

47

42

38

45

41

37

43

39

36

42

38

35

34

4

51

42

36

32

49

42

36

31

40

35

31

38

34

31

37

33

30

29

5

47

38

32

27

45

37

31

27

36

31

27

34

30

26

33

29

26

25

6

43

34

28

24

42

33

28

23

32

27

23

31

26

23

30

26

23

21

7

40

31

25

21

39

30

25

21

29

24

20

28

24

20

27

23

20

19

8

37

28

22

18

36

27

22

18

27

22

18

26

21

18

25

21

18

17

9

34

26

20

16

34

25

20

16

24

20

16

24

19

16

23

19

16

15

10

32

24

18

15

31

23

18

15

23

18

15

22

18

15

21

17

15

13

Z o n a l L u m e n S u m m a r y

Ty p i c a l V C P P e r c e n t a g e s

 

 

 

 

 

 

 

 

Height Along

Height Across

Zone

Lumens

%Lamp

%Fixture

Room Size (Ft.)

8.5'

10.0'

8.5'

10.0'

0-30

789

15.0

23.5

 

20 x 20

59

66

51

61

0-40

1306

24.9

38.9

 

30 x 30

52

56

43

49

0-60

2385

45.4

71.1

 

30 x 60

47

50

33

37

0-90

3353

63.9

100.0

 

60 x 30

52

56

47

43

0-180

3353

63.9

100.0

 

60 x 60

46

49

35

39

ORDERING INFORMATION

SA M PLE N UM BE R: 2 R D I - 2 1 4 T 5 R P D - 1 2 0 V- E B T 1- U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 = 2' Width

 

 

 

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

of Lamps

 

 

 

 

 

 

 

 

 

 

 

(Not included)

 

Ovation Series

 

 

 

 

 

1=1 Lamp

 

RDI=Recessed

 

 

 

 

 

2=2 Lamp

 

Direct/Indirect

 

 

 

 

 

3=3 Lamp

 

 

 

 

 

 

 

 

 

 

 

Trim Type

 

 

 

 

 

Leave Blank=Grid/Lay- in

 

 

 

 

 

(Standard)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Leave Blank=Center mounted

Lamps (standard)

Wattage (Length)

Lamp Shield

RPD=RoundPerforated

Steel Below Ceiling Lamp

Shield

RPD/TBW=Round Perforated Below Ceiling Lamp Shield withThin Blade White Baffle

Voltage( 2)

120V=120 Volt

277V=277 Volt

UNV=Universal

Voltage 120-277

BallastType (2)

EBT =T5 Linear Electronic Program Rapid StartTotal Harmonic Distortion < 10%

No. of Ballast 1,2 or 3

DLS=Digital Lighting System Dimming

 

 

 

 

 

 

 

 

 

 

Options

 

Packaging

RIF1=Radio Interference

 

U=Unit Pack

Suppressor

 

PALC=Job Pack,

EQ-Clip-U=T-Bar EQ Clip

 

in carton

(Order Individually as Accessory. Use Four Per Fixture.)

DF-22-W=Drywall Frame Kit (Order Individually as Accessory.) REP=Riveted Endplates, for use in NewYork City. ST=Semi-SpecularTannenbaum Main Reflector

LSC=Lamp Shield Cable

14T5=14WT5 (24")(1)

24T5=24WT5HO (24")(1)

Options

GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps installed F l e x=Flex installed

NOTES:

(1)2' x 2' and 2' x 4' Center Lamp Shield models only.

(2)Products also available in non-US voltages and frequencies for international markets.

ACCESSORIES

EQ = T-BAR Safety Earthquake Clips

(Use Four Per Fixture)

DF-22-W= Drywall Frame Kit

SHIPPING INFORMATION

 

Catalog No.

Wt.

 

 

2RDI-114T5RPD

17 lbs.

 

2RDI-214T5RPD

17 lbs.

 

2RDI-314T5RPD

17 lbs.

 

 

 

 

Specifications and Dimensions subject to change without notice.

ADF032747

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

08/02/2008 3:16:54 PM

Page 2
Image 2
Cooper Lighting Photometrics, 2RDI-224T5RPD, 2RDI-324T5RPD, Ordering Information, Accessories, Shipping Information