PHOTOMETRICS | 2RDI |
|
|
2RDI-224T5RPD
⊥Electronic Ballast
(2) F24T5HO/830 Lamps
1750 Lumens
C a n d e l a |
|
|
|
| ||
|
|
|
| ⊥ | Electronic Ballast | |
Angle | Along II | 45o | Across ⊥ | (2) F24T5HO/830 | ||
| ||||||
0 | 631 | 631 | 631 |
| lamps | |
5 | 630 | 630 | 629 |
| ||
| 1750 lumens | |||||
10 | 622 | 623 | 625 |
|
C a n d e l a
Angle | Along II | 45o | Across ⊥ |
0 | 1001 | 1001 | 1001 |
5 | 1002 | 998 | 996 |
10 | 989 | 988 | 988 |
Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.3 x mounting height
Efficiency 61.7%
Test Report: 2RDI224T5RPD.IES
LER = FL39
Yearly Cost of 1000 lumens, 3000 hrs at
.08 KWH = $6.11
15 | 608 | 612 | 616 |
| Spacing criterion: |
20 | 588 | 596 | 604 |
| (II) 1.3 x mounting |
25 | 563 | 576 | 589 |
| |
| height, (⊥) 1.3 x | ||||
30 | 533 | 553 | 570 |
| |
| mounting height | ||||
35 | 497 | 525 | 549 | ||
40 | 457 | 494 | 524 | Efficiency 63.9% | |
45 | 412 | 460 | 496 |
| |
| Test Report: | ||||
50 | 364 | 424 | 466 |
| |
55 | 312 | 385 | 433 |
| 2RDI324T5RPD.IES |
60 | 257 | 344 | 398 |
| LER = FL42 |
65 | 202 | 302 | 360 |
| |
| Yearly Cost of 1000 | ||||
70 | 150 | 259 | 318 |
| |
75 | 105 | 215 | 280 |
| lumens, 3000 hrs at |
80 | 65 | 175 | 242 |
| .08 KWH = $5.72 |
85 | 32 | 134 | 197 |
| |
|
| ||||
90 | 0 | 0 | 0 |
|
|
15 | 967 | 969 | 974 |
20 | 935 | 943 | 953 |
25 | 894 | 910 | 926 |
30 | 847 | 871 | 894 |
35 | 789 | 825 | 858 |
40 | 724 | 774 | 816 |
45 | 652 | 717 | 770 |
50 | 575 | 658 | 722 |
55 | 491 | 596 | 669 |
60 | 403 | 531 | 611 |
65 | 314 | 463 | 549 |
70 | 230 | 394 | 482 |
75 | 159 | 325 | 417 |
80 | 97 | 257 | 354 |
85 | 48 | 197 | 291 |
90 | 0 | 0 | 0 |
C o e f f i c i e n t s o f U t i l i z a t i o n
| Effective floor cavity reflectance | 20% |
|
|
|
|
|
|
|
|
| |||||||
rc |
| 80% |
|
| 70% |
|
| 50% |
|
| 30% |
|
| 10% |
| 0% | ||
rw | 70 | 50 | 30 | 10 | 70 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 |
RCR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 | 74 | 74 | 74 | 74 | 72 | 72 | 72 | 72 | 69 | 69 | 69 | 66 | 66 | 66 | 63 | 63 | 63 | 62 |
1 | 66 | 62 | 59 | 56 | 64 | 61 | 58 | 55 | 58 | 55 | 53 | 55 | 53 | 52 | 53 | 52 | 50 | 49 |
2 | 59 | 53 | 48 | 44 | 57 | 52 | 48 | 44 | 50 | 46 | 43 | 48 | 45 | 42 | 46 | 43 | 41 | 39 |
3 | 54 | 46 | 41 | 36 | 52 | 45 | 40 | 36 | 43 | 39 | 35 | 42 | 38 | 35 | 40 | 37 | 34 | 33 |
4 | 49 | 41 | 35 | 30 | 47 | 40 | 34 | 30 | 38 | 33 | 30 | 37 | 33 | 29 | 35 | 32 | 29 | 27 |
5 | 45 | 36 | 30 | 26 | 43 | 36 | 30 | 26 | 34 | 29 | 25 | 33 | 29 | 25 | 32 | 28 | 25 | 23 |
6 | 41 | 33 | 27 | 22 | 40 | 32 | 26 | 22 | 31 | 26 | 22 | 30 | 25 | 22 | 29 | 25 | 22 | 20 |
7 | 38 | 29 | 24 | 20 | 37 | 29 | 23 | 20 | 28 | 23 | 19 | 27 | 23 | 19 | 26 | 22 | 19 | 18 |
8 | 36 | 27 | 21 | 18 | 35 | 26 | 21 | 17 | 26 | 21 | 17 | 25 | 20 | 17 | 24 | 20 | 17 | 16 |
9 | 33 | 25 | 19 | 16 | 32 | 24 | 19 | 16 | 23 | 19 | 16 | 23 | 19 | 15 | 22 | 18 | 15 | 14 |
10 | 31 | 23 | 18 | 14 | 30 | 22 | 17 | 14 | 22 | 17 | 14 | 21 | 17 | 14 | 21 | 17 | 14 | 13 |
Z o n a l L u m e n S u m m a r y | Ty p i c a l V C P P e r c e n t a g e s |
|
| ||||||
|
|
|
|
|
| Height Along | Height Across | ||
Zone | Lumens | %Lamp | %Fixture | Room Size (Ft.) | 8.5' | 10.0' | 8.5' | 10.0' | |
499 | 14.3 | 23.1 |
| 20 x 20 | 67 | 75 | 60 | 69 | |
827 | 23.6 | 38.3 |
| 30 x 30 | 61 | 66 | 52 | 58 | |
1519 | 43.4 | 70.3 |
| 30 x 60 | 57 | 60 | 41 | 46 | |
2160 | 61.7 | 100.0 |
| 60 x 30 | 61 | 65 | 56 | 62 | |
2160 | 61.7 | 100.0 |
| 60 x 60 | 55 | 58 | 44 | 48 |
C o e f f i c i e n t s o f U t i l i z a t i o n
| Effective floor cavity reflectance | 20% |
|
|
|
|
|
|
|
|
| |||||||
rc |
| 80% |
|
| 70% |
|
| 50% |
|
| 30% |
|
| 10% |
| 0% | ||
rw | 70 | 50 | 30 | 10 | 70 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 |
RCR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 | 76 | 76 | 76 | 76 | 74 | 74 | 74 | 74 | 71 | 71 | 71 | 68 | 68 | 68 | 65 | 65 | 65 | 64 |
1 | 68 | 64 | 61 | 58 | 66 | 63 | 60 | 57 | 60 | 58 | 55 | 58 | 55 | 54 | 55 | 54 | 52 | 51 |
2 | 61 | 55 | 50 | 46 | 60 | 54 | 50 | 46 | 52 | 48 | 45 | 50 | 46 | 44 | 48 | 45 | 43 | 41 |
3 | 56 | 48 | 42 | 38 | 54 | 47 | 42 | 38 | 45 | 41 | 37 | 43 | 39 | 36 | 42 | 38 | 35 | 34 |
4 | 51 | 42 | 36 | 32 | 49 | 42 | 36 | 31 | 40 | 35 | 31 | 38 | 34 | 31 | 37 | 33 | 30 | 29 |
5 | 47 | 38 | 32 | 27 | 45 | 37 | 31 | 27 | 36 | 31 | 27 | 34 | 30 | 26 | 33 | 29 | 26 | 25 |
6 | 43 | 34 | 28 | 24 | 42 | 33 | 28 | 23 | 32 | 27 | 23 | 31 | 26 | 23 | 30 | 26 | 23 | 21 |
7 | 40 | 31 | 25 | 21 | 39 | 30 | 25 | 21 | 29 | 24 | 20 | 28 | 24 | 20 | 27 | 23 | 20 | 19 |
8 | 37 | 28 | 22 | 18 | 36 | 27 | 22 | 18 | 27 | 22 | 18 | 26 | 21 | 18 | 25 | 21 | 18 | 17 |
9 | 34 | 26 | 20 | 16 | 34 | 25 | 20 | 16 | 24 | 20 | 16 | 24 | 19 | 16 | 23 | 19 | 16 | 15 |
10 | 32 | 24 | 18 | 15 | 31 | 23 | 18 | 15 | 23 | 18 | 15 | 22 | 18 | 15 | 21 | 17 | 15 | 13 |
Z o n a l L u m e n S u m m a r y | Ty p i c a l V C P P e r c e n t a g e s |
|
| ||||||
|
|
|
|
|
| Height Along | Height Across | ||
Zone | Lumens | %Lamp | %Fixture | Room Size (Ft.) | 8.5' | 10.0' | 8.5' | 10.0' | |
789 | 15.0 | 23.5 |
| 20 x 20 | 59 | 66 | 51 | 61 | |
1306 | 24.9 | 38.9 |
| 30 x 30 | 52 | 56 | 43 | 49 | |
2385 | 45.4 | 71.1 |
| 30 x 60 | 47 | 50 | 33 | 37 | |
3353 | 63.9 | 100.0 |
| 60 x 30 | 52 | 56 | 47 | 43 | |
3353 | 63.9 | 100.0 |
| 60 x 60 | 46 | 49 | 35 | 39 |
ORDERING INFORMATION
SA M PLE N UM BE R: 2 R D I - 2 1 4 T 5 R P D - 1 2 0 V- E B T 1- U
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 = 2' Width |
|
|
|
|
|
|
| Number | |||
|
|
|
|
|
|
|
|
|
|
| of Lamps | |
|
|
|
|
|
|
|
|
|
|
| (Not included) | |
| Ovation Series |
|
|
|
|
| 1=1 Lamp | |||||
| RDI=Recessed |
|
|
|
|
| 2=2 Lamp | |||||
| Direct/Indirect |
|
|
|
|
| 3=3 Lamp | |||||
|
|
|
|
|
|
|
|
|
| |||
| Trim Type |
|
|
|
| |||||||
| Leave Blank=Grid/Lay- in |
|
|
|
| |||||||
| (Standard) |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Leave Blank=Center mounted
Lamps (standard)
Wattage (Length)
Lamp Shield
RPD=RoundPerforated
Steel Below Ceiling Lamp
Shield
RPD/TBW=Round Perforated Below Ceiling Lamp Shield withThin Blade White Baffle
Voltage( 2)
120V=120 Volt
277V=277 Volt
UNV=Universal
Voltage
BallastType (2)
EBT =T5 Linear Electronic Program Rapid StartTotal Harmonic Distortion < 10%
No. of Ballast 1,2 or 3
DLS=Digital Lighting System Dimming
|
|
|
|
|
|
|
|
|
|
Options |
| Packaging | ||
RIF1=Radio Interference |
| U=Unit Pack | ||
Suppressor |
| PALC=Job Pack, | ||
| in carton |
(Order Individually as Accessory. Use Four Per Fixture.)
LSC=Lamp Shield Cable
14T5=14WT5 (24")(1)
24T5=24WT5HO (24")(1)
Options
GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps installed F l e x=Flex installed
NOTES:
(1)2' x 2' and 2' x 4' Center Lamp Shield models only.
(2)Products also available in
ACCESSORIES
EQ =
(Use Four Per Fixture)
SHIPPING INFORMATION
| Catalog No. | Wt. |
|
| 17 lbs. | ||
| 17 lbs. | ||
| 17 lbs. | ||
|
|
|
|
Specifications and Dimensions subject to change without notice. | ADF032747 | ||
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 | 08/02/2008 3:16:54 PM |