Thermal Performance
Cooper Lighting thermally tested each configuration to determine the optimal luminaire operating temperature range. When specifying luminaires use the lowest temperature the luminaire will be exposed to during operating hours. However, facility temperatures fluctuate and luminaires exposed to temperatures less than stated are not recommended.
To maximize energy efficiency, some facilities will operate chillers only during
40ft.
30ft.
20ft.
10ft.
Freezer Temperature Ranges
35 ft. @
20 ft. @ |
10 ft. @ |
Temperature Control Capability
Cooper Lighting recommends the following lamp operation when implementing a control system in colder ambient environments.
Arctic Bay (AB) Series
|
|
| Motion Sensor Options (Number of Lamps Controlled) | |
|
| Lamp | Routine | Occasional |
Fixture | # Lamps | Type | Use | Use(3) |
4 Lamp | T5HO | Not Recommended | 2 | |
|
|
|
|
|
6 Lamp | T5HO | Not Recommended | 2 | |
|
|
|
|
|
0°F |
|
| Motion Sensor Options (Number of Lamps Controlled) | |
|
| Lamp | Routine | Occasional |
Fixture | # Lamps | Type | Use (1) | Use(2) |
4 Lamp | T5HO | 2 | ALL | |
|
|
|
|
|
6 Lamp | T5HO | 2 | 4 | |
|
|
|
|
|
32°F (0°C) – 50°F (10°C) |
| Motion Sensor Options (Number of Lamps Controlled) | ||
|
| Lamp | Routine | Occasional |
Fixture | # Lamps | Type | Use(1) | Use(2) |
4 Lamp | T5HO | 2 | ALL | |
|
|
|
|
|
6 Lamp | T5HO | 2 | 4 | |
|
|
|
|
|
NOTES: (1)Luminaire achieves 40% or greater of relative light output at the indicated temperature in under 60 seconds. (2)Luminaire achieves 40% to 80% of relative light output at the indicated temperature in under 7 minutes. (3)Consult factory.
ORDERING INFORMATION
S A M P L E N U M B E R :
Width
Blank=15"
2=24"
Series
AB=Arctic Bay
Mounting Arrangement
Blank=Stand Alone
R=Continuous Row Mount
No. of Lamps
4=4 Lamps (AB)
6=6 Lamps (2AB)
Lamp Type
54T5=T5HO Lamps (48")
Distribution
Blank=Medium (Specular Aluminum) G=Wide (White Painted)
Shielding
Blank=Prismatic Acrylic Lens w/Gasketed Doorframe CL=Clear Acrylic Lens w/Gasketed Doorframe
Voltage(2)
UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage (T5 linear only) 120V=120 Volt
277V=277 Volt
347V=347 Volt
Options
Lamps Installed
L5835=T5 Lamp, 80CRI 3500K
L5841=T5 Lamp, 80CRI 4100K
L5850=T5 Lamp, 80CRI 5000K
GL=Single Element Fuse
GM=Double Element Fuse Emergency=Please Consult Factory(2)
BallastType
EBTL =T5 Linear Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
Minimum StartTemp.
No. of Ballast 1, 2 or 3
DIM=Consult Factory(6)
Options(6)
C3=3' White Cord Fixture Attached
C6=6' White Cord Fixture Attached MS=Aisle Coverage Motion Sensor(3) MSO=360˚ Coverage Motion Sensor(3) MS/OB=Aisle Modular Sensor Wired with Inner Two Lamps Constant On(3) MSO/OB=360˚ Modular Sensor Wired with Inner Two Lamps Constant On(3) MS/AO=Aisle Motion Sensor/Alternate Off (Alternate Ballast Relay)(3), (4) MSO/AO=360˚ Motion Sensor/Alternate Off (Alternate Ballast Relay)(3), (4)
Packaging
U=Unit Pack
PAL=Palletized Out of Carton
PALC=Job Pack In Carton
Accessories (order separately)
Gripple
SHIPPING INFORMATION
NOTES: (1)Requires use of voltage specific modular cord assembly. See accessories. (2)Voltage must be specified when ordered with plugs, motion or emergency ballasts. (3)Specify voltage. (4)Requires (2) ballasts. Not available in 480V. (5)Dimming ballasts not recommended for use at temperature < 0°F
Catalog No. | Wt. |
25 lbs. | |
27 lbs. |
Specifications and Dimensions subject to change without notice. | ADF071257 |