Catalog #

DESCRIPTION

The Fail-Safe CFF Series is designed for use in horizontal or non-laminar air flow clean rooms. The enclosed and gasketed housing and one-piece, out- side flanged door protect against infiltration of airborne bacteria. The die formed edges on the door frame and the hole-free design of the housing prevent air exchange between the fixture and plenum, allowing relamping without contamination of the clean areas. These luminaires are U.L. listed and C.S.A. certified for wet locations and are manufactured in accordance with U.S.D.A., F.D.A., N.S.F. and Federal Standard 209E. 200 PSI Hose Down Rating standard.

SPECIFICATION FEATURES

Catalog #

Project

Comments

Prepared by

FAIL-SAFE®

TypeDate

Application

The CFF Series is suitable for use in I.E.S. Class 100, 1,000, 10,000 and 100,000 clean room environ- ments. Applications include clean rooms, technical and biomedical labs, food processing/testing centers and pharmaceutical labs.

A ... Lens

Lens is clear extruded with prisms positioned inside fixture and smooth surface on the outside for easy cleaning.

B ... Fasteners

Flush mounted, stainless steel machine screws secure through captive cage nuts in housing and are evenly spaced to compress gasketing on all sides.

C ... Housing

Die-formed, 20 ga. CRS with tightly butted and seam welded, sealed end caps. Contains no holes that would allow air passage. Standard white high reflectance polyester powder coat finish. Gloss: 85%; Reflectance: 93%; Hardness: 2H;

D ... Lamps

(By Others)

E ... Lens Retention

Unique, Particulock(TM) lens retention system utilizes con- tinuous, 18 ga. media clampdowns to sandwich gasketing and integrate lens and door frame for even environmental seal.

F ... Hinge

Two braided, stainless steel cables on one side of door provide hinging.

G ... Door

One piece, 18 ga. door with baked white polyester powder coat, fully gasketed, outside door with die- formed edges eliminates seams which could entrap microscopic contaminants. Optional doors available.

H ... Ballast

Standard Class P, CBM/ETL ballast.

I ... Gasket

White, closed cell, Flexiseal(TM) gasketing surrounds perimeter of lens to seal lens to door frame and around perimeter of door to seal door to housing. Another layer seals fixture to ceiling system after installation.

J ... Access

A gasketed access plate on top of the housing with two flattened, 7/8" diameter knockouts allows connection of vapor tight conduit fitting. Optional, above ceiling, top access door for luminaire main- tenance is available and ideal for food processing and cleanroom applications.

Labels

U.L. listed, C.S.A. certified, standard wet label.

CFF

34W - 160W

Fluorescent

2' X 2'

2' X 4'

FLUORESCENT FLANGE One-Piece Door

Salt Spray: 500 Hours.

H J D C

 

 

 

4 3/8"

 

 

B

[111mm]

F

 

3 3/4"

 

 

[95mm]

I

22 11/16" [576mm]

E

G

A

 

24 1/4"

[616mm]

 

 

 

26" [660mm]

 

 

MOUNTING DIMENSIONS

(4)3/16" [5mm] Dia. Yoke Mounting Hole

Project 36" Prepared by [914mm]

48 5/16"

[1227mm]

(2) 7/8" [22mm] KO

(4) 3/16" [5mm] Dia.

(2) 7/8" [22mm] KO

Yoke Mounting Hole

Gasketed Access Plate

 

 

 

Gasketed Access Plate

23 1/16" [586mm]

 

 

23 1/16" [586mm]

Ceiling Cut-Out

 

 

 

Ceiling Cut-Out

 

 

 

 

 

9 11/16"

25 1/4"

 

 

 

9 11/16"

25 1/4"

[246mm]

[641mm]

 

 

 

[246mm]

[641mm]

1 1/2"

 

1 1/2"

 

1 3/4"

 

[38mm]

 

[38mm]

12"

[44mm]

 

 

 

 

 

 

 

 

 

 

[305mm]

 

 

 

 

 

 

24 5/16"

 

 

 

 

 

 

[617mm]

 

 

 

E N E R G Y D A TA

Input Watts:

STD Ballasts & STD Lamps

(2)20W T12 Fluorescents: 53W

(3)20W T12 Fluorescents: 85W

(4)20W T12 Fluorescents: 106W

(2)40W Biaxial Fluorescents: 82W

(3)40W Biaxial Fluorescents: 127W

ES Ballasts & STD Lamps

(2)

17W

T8

Fluorescents: 45W

(3)

17W

T8

Fluorescents: 68W

(4)

17W

T8

Fluorescents: 90W

(2)

32W

T8

Fluorescents: 71W

(3)

32W

T8

Fluorescents: 108W

(4)

32W

T8

Fluorescents: 142W

(2)

40W

T12 Fluorescents: 86W

LAMP CONFIGURATIONS

 

 

 

 

 

DOOR FRAME

9 1/2"

5"

5"

5"

9 1/2"

Flange Type-One-piece Door

[241mm]

[127mm] [127mm] [127mm]

[241mm]

 

7 1/2"

7 1/2"

6"

3"

6"

4 3/4"

4 3/4"

 

[190mm] [190mm]

[152mm] [76mm] [152mm]

[121mm]

[121mm]

 

Specifications and Dimensions subject to change without notice.

Consult your representative for additional options and finishes.

(3)

40W T12 Fluorescents: 136W

(4)

40W T12 Fluorescents: 172W

(2)

40W U-Lamps: 86W

ES Ballasts & ES Lamps

(2)40W T12 Fluorescents: 76W

(3)40W T12 Fluorescents: 120W

(4)40W T12 Fluorescents: 152W

(2)40W U-Lamps: 76W

Electronic Ballast Data

Consult Cooper Lighting Representative.

ADC040912 04/04/2007 2:45:37 PM

Page 1
Image 1
Cooper Lighting CFF specifications 34W - 160W, Fail-Safe, Catalog #, Project Comments, Prepared by, Type, Date