Cooper Lighting Test No. ITL36036, CFS-24-440-IK12, Lamp=4 40WT12, Lumens=8526, =1.2, =1.4

Models: CFS

1 2
Download 2 pages 1.41 Kb
Page 2
Image 2
Test No. ITL36036

CFS

PHOTOMETRICS

C a n d l e p ower Distribution

 

Av erage

 

 

Zonal Lumen Summary

 

 

 

 

 

 

Luminance

 

 

Zone

Lumens

%Lamp

%Luminaire

 

Test No. ITL36036

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Deg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-30

2728

21.7

32.0

 

CFS-24-440-IK12

 

 

 

 

 

 

 

 

 

45

1595

1323

 

 

 

 

 

500

0-40

4499

35.7

52.8

Lamp=(4) 40WT12

 

 

 

 

 

 

 

 

55

1154

980

 

 

0-60

7316

58.1

85.8

 

Lumens=8526

 

 

 

 

 

 

 

 

 

 

65

822

779

 

 

 

0-90

8526

67.7

100.0

 

Spacing Criteria

 

1000

 

75

871

857

 

 

90-180

0

0.0

0.0

 

 

 

=1.4

=1.2

85

1018

933

 

 

 

 

 

0-180

8526

67.7

100.0

 

 

1500

Efficiency=67.7%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000

2500

Coefficient of Utilization

rc

 

 

 

80%

 

 

70%

 

 

50%

 

30%

 

10%

0%

rw

70

50

30

10

50

30

10

50

10

50

10

50

10

0

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

81

81

81

81

79

79

79

75

75

72

72

69

69

68

1

 

75

72

69

67

70

68

66

67

64

65

62

62

60

59

2

 

69

64

60

57

63

59

56

61

55

58

54

56

52

51

3

 

64

58

53

49

57

52

48

55

48

53

47

51

46

45

4

 

59

52

46

42

51

46

42

49

42

48

41

46

40

39

5

 

54

46

41

37

46

40

36

44

36

43

36

42

35

34

6

 

50

42

36

32

41

36

32

40

32

39

31

38

31

30

7

 

46

38

32

28

37

32

28

36

28

35

28

34

28

26

8

 

43

34

28

25

33

28

24

33

24

32

24

31

24

23

9

 

39

30

25

21

30

25

21

29

21

29

21

28

21

20

10

 

37

28

22

19

27

22

19

27

19

26

19

25

19

17

rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance.

ORDERING INFORMATION

Specifications and Dimensions subject to change without notice.

ADC041650

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

08/29/2007 2:09:42 PM

Page 2
Image 2
Cooper Lighting Test No. ITL36036, CFS-24-440-IK12, Lamp=4 40WT12, Lumens=8526, Spacing Criteria, =1.2, =1.4