CLASSICAL—CLB-1 Post Top Luminaire

CLASSICAL—CLB-1 Post Top Luminaire

APPLICATION

The CLB series contemporary lines and style transitions to a more traditional fluted design. Its style makes an excellent transitional design for many of today’s application. Great for today’s trends of planned communities, outdoor retail applications and school campuses.

PHOTOMETRIC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

6

FOOTCANDLE TABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

5

Select mounting height and read across for

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

4

footcandle values of each isofootcandle line.

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

3

Distance in units of mounting height.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

2

Mounting

Footcandle Values for

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

1

Height

Isofootcandle Lines

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

1

REPORT #768227

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10'

4.50

2.25

1.12

0.45

0.22

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15'

2.00

1.00

0.50

0.20

0.10

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20'

1.12

0.56

0.28

0.11

0.05

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

5

REPORT #768230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

6

10'

2.25

1.12

0.45

0.22

0.11

6

5

4

3

2

1

0

1

2

3

4

5

6

6

5

4

3

2

1

0

1

2

3

4

5

6

15'

1.00

0.50

0.20

0.10

0.05

REPORT #768227

 

 

 

 

 

 

REPORT #768230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20'

0.56

0.28

0.11

0.05

0.02

15' Mounting Height

 

 

 

 

 

 

 

15' Mounting Height

 

 

 

 

 

 

 

 

 

 

 

 

 

175-Watt MH, Type III Acrylic Refractor

 

 

 

175-Watt MH, Type V Acrylic Refractor

 

 

 

 

 

 

 

 

 

14,000-Lumen Clear ED-28 Lamp

 

 

 

 

14,000-Lumen Clear ED-28 Lamp

 

 

 

 

 

 

 

 

 

 

DIMENSIONS

COEFFICIENTS OF UTILIZATION

24 3/4"

[629mm]

Utilizationsof

0.5

 

 

 

Street Side

Utilizationsof

 

 

 

 

0.4

 

 

 

 

#768227—Coefficients

 

 

 

 

Coefficients—#768230

0.3

 

 

 

House Side

 

 

 

 

 

 

 

 

 

 

 

 

0.2

 

 

 

 

 

REPORT

0.1

 

 

 

 

REPORT

 

 

 

 

 

 

0.0

1

2

3

4

5

 

0

 

 

Street Width/Mounting Height

 

0.5

0.4

0.3

0.2

0.1

0.0

0

Street Side

House Side

1

2

3

4

5

Street Width/Mounting Height

APPLICATION 18 3/4" [476mm] PHOTOMETRIC

TOPS/FINIAL OPTIONS

LUMENS OUTPUT & EFFICIENCY

REPORT #768227

LUMENS

PERCENT

 

REPORT #768230

LUMENS

PERCENT

OF LAMP

 

OF LAMP

 

 

 

 

 

Downward Street Side

6907.66

49.3

 

Downward Street Side

5227.82

37.3

Downward House Side

3842.81

27.4

 

Downward House Side

5227.81

37.3

Downward Total

10750.47

76.8

 

Downward Total

10455.63

74.7

Upward Street Side

1010.32

7.2

 

Upward Street Side

938.26

6.7

Upward House Side

779.1

5.6

 

Upward House Side

938.25

6.7

Upward Total

1789.42

12.8

 

Upward Total

1876.51

13.4

Total Flux

12539.89

89.6

 

Total Flux

12332.14

88.1

AC O R N ( G L O W TO P )

M O D E R N

V I C TO R I A N ( G L O W TO P )

C L A S S I C A L

V I C TO R I A N

M O D E R N A R C H I T E C T U R A L

ORDERING INFORMATION

CLB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Family

 

Lamp

Lamp Type

 

Ballast Type

Voltage

Refractor

Cage Type

CLB=Classical

 

Wattage

M=Metal

 

R=Reac./NPF

2=120V

Type

1=Classical

 

 

50=50W

 

Halide

 

H=Reac./HPF

0=208V

33=Type III

2=Modern

 

 

70=70W

S=High

 

N=Hi. Reac./NPF

4=240V

55=Type V

3=Architectural

 

 

10=100W

Pressure

 

P=Hi. Reac./HPF

7=277V

 

 

 

X=None

 

 

15=150W

Sodium

 

W=CWA

8=480V

 

 

 

 

 

 

 

 

 

17=175W

 

 

 

 

K=10KV CWA

9=347V

 

 

 

 

 

 

 

 

 

25=250W

 

 

 

 

 

 

 

 

W=Multi-Tap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wired 120V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N=Multi-Tap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wired 277V

 

 

 

 

 

 

 

NOTE: 1 When brass banding is choosen, finial finished in gold. Specifications and Dimensions subject to change without notice.

Top Type

1=Acorn

2=Modern

3=Victorian

4=Classical

Finial Type

1=Victorian

2=Modern

3=Architectural X=None

Options (add as suffix)

1=Single Fuse (120, 277V)

2=Double Fused (208, 240 or 480V)

4=Internal NEMA Photocontrol Receptacle

6=White

8=Bronze

B=Decorative Brass Banding 1 H=Hartford Green SY=Silver P=Polycarbonate Refractor R=Downlight Reflector A=Twistlock Refractor

Accessories (order separately) AA1000=House Side Shield

www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADW010222

Page 2
Image 2
Cooper Lighting Classical CLB-1 CLASSICAL-CLB-1Post Top Luminaire, Application, Dimensions, Coefficients Of Utilization