COOPER LIGHTING
FAIL-SAFE®

CONFINEMENT

C
B
B
A
DIMENSIONS
Lens choice of prismatic
acrylic, prismatic poly-
carbonate or prismatic
tempered glass on fixture
side, clear polycarbonate
or clear tempered glass on
environmental side
Stainless steel tamper-
resistant TORX®screws
with center pin reject are
standard. Allen-head
screws with center pin
reject are optional
Clamshell design
combines die-formed 12,
14 or 16 ga. CRS body with
continuous welded and
ground 12 ga. ends.
Standard white high
reflectance polyester
powder coat finish
Lamps by others
Lens secured by thru-studs
and vertically adjustable
internal CRS hold-downs
Internal security hinge
Die-formed CRS backplate
(gauge to match housing)
Standard Class P, CBM/ETL
ballast
U.L. listed, C.S.A. certified
standard damp label
DESCRIPTION
The Fail-Safe FCT Series
combines maximum security
construction features with
energy saving technology. This
low profile surface mounted
luminaire has a clamshell
housing, security lensing and
tamper resistant fasteners to
maximize impact resistance
and prevent contraband
concealment and unauthorized
fixture penetration. Can be
ceiling or wall mounted. An
emergency battery pack is
available as an option. U.L.
listed and C.S.A. certified for
damp locations.

FCT

28W-120W
Fluorescent
ULTIMAX SURFACE
LUMINAIRE
MOUNTING
ABC
2' Nom. Length 4 7/8" 19 7/16" 26 1/4"
(124mm) (494mm) (667mm)
4' Nom. Length 4 7/8"" 19 7/16" 50 1/4"
(124mm) (494mm) (1276mm)
Ballast
Blank=Magnetic Ballast (Standard) 3
LEOC8=T8 Energy Saving Ballast
LE3=40W T12 Energy Saving Ballast
Electronic Ballast1
EB81=(1) Ballast for use with T8 Lamp
EB82=(2) Ballasts for use with T8 Lamp
EB51=(1) Ballast for use with T5 Lamp
EB52=(2) Ballasts for use with T5 Lamp
EB21=(1) Ballast for use with T12 Lamp2
EB22=(2) Ballasts for use with T12 Lamp2
EBX1=(1) Ballast for use with Biaxial Lamp
EBX2=(2) Ballasts for use with Biaxial Lamp
ORDERING INFORMATION
SAMPLE NUMBER: FCT-S-340-277-80/86-LE3-TCS
Product Family
Surface Luminaires
FCT-S=12 ga.
(Ultimax)
FCT-X=14 ga.
(Maximum)
FCT-D=16 ga.
(Medium)
Options
CPH=Continuous
Concealed Piano
Hinge
EBP=Emergency Battery
Pack
(4' fixtures only)
FNL=Fluorescent Night
Light (Lamp
by others.)
GLR=Fuse and Holder
RIF=Radio Interference
Filter
SPK=Speaker Housing
Compartment
(extends housing)
Auto Control Modules
ACM/FNL=for FNL
On/Off Switches
SPS=Security Push Button
TCS=Touch Control
System 4
Stainless Steel Housing
SSN=Natural Brushed
Finish
SSP=Polyester Powder
Coat Finish
Fasteners
SF3=Allen-Head
(center pin reject)
Notes: For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change without
notice. Electronic ballast may cause interference with other electronic devices. If interference occurs, move the device away from the
product or plug/connect into a different circuit/outlet.
1For specific electronic ballast, specify brand and catalog number. 2Electronic ballast not available for F20T12 lamps. 3For use with
Compact Fluorescent, Biaxial, and 20W T12 lamps. 4For additional information about the TCS option see pages 1106 and 1107.
Lens Type
Inner Layer
(optional)
90=.005 UV
Absorbing
Overlay
Fixture Side
80=.125 Prismatic
Acrylic
81=.156 Prismatic
Polycarbonate
82=.187 Prismatic
Polycarbonate
93=.156 Prismatic
Tempered
Glass
Environmental
Side
84=.125 Clear
Polycarbonate
85=.187 Clear
Polycarbonate
86=.250 Clear
Polycarbonate
87=.375 Clear
Polycarbonate
88=.500 Clear
Polycarbonate
94=.187 Clear
Tempered
Glass
96=.250 Clear
Tempered
Glass
97=.375 Clear
Tempered
Glass
98=.500 Clear
Tempered
Glass
Accessories (Order Separately)
9306=Allen-Head Wrench
VRSD=TORX®-Head Vandal
Resistant Screwdriver
Voltage
120=120V
277=277V
UNV=120V through 277V
/
Lamp Type
2' Nom. Length
T5 Fluorescents
214=(2) 14W Lamps
314=(3) 14W Lamps
T8 Fluorescents
217=(2) 17W Lamps
317=(3) 17W Lamps
T12 Fluorescents2
220=(2) 20W Lamps
320=(3) 20W Lamps
Biaxial Fluorescents
240BX=(2) 40W Lamps
340BX=(3) 40W Lamps
4' Nom. Length
T5 Fluorescents
228=(2) 28W Lamps
328=(3) 28W Lamps
T8 Fluorescents
232=(2) 32W Lamps
332=(3) 32W Lamps
T12 Fluorescents
240=(2) 40W Lamps
340=(3) 40W Lamps
C
B
B
A
1452