Cooper Lighting FWSCR-340-120, Photometrics, Candlepower Distribution, Zonal Lumen Summary

Models: FWSCR

1 2
Download 2 pages 26.89 Kb
Page 2
Image 2
PHOTOMETRICS

FWSCR

PHOTOMETRICS

Candlepower Distribution

 

 

 

 

 

 

Candlepower

 

 

 

Zonal Lumen Summary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

Lumens

 

%Lamp

%Luminaire

 

 

 

 

Test No. 4870

 

Deg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

2107

 

2107

 

 

0-30

1641

 

17.1

31.3

 

 

 

 

 

FWSCR-340-120

 

 

 

 

 

 

 

 

450

 

5

2111

 

2107

 

 

0-40

2765

 

28.8

52.8

 

 

 

 

Lamp=(3) F40T12RS/

 

 

 

 

 

 

 

15

2123

 

2044

 

 

0-60

4137

 

43.1

79.0

 

 

 

 

 

 

 

 

WW

 

 

 

 

 

 

 

 

 

 

 

 

 

25

2105

 

1876

 

 

0-90

4933

 

51.4

94.1

 

 

 

 

900

Lumens=3200

 

 

 

 

 

 

 

 

 

35

1928

 

1567

 

 

90-180

307

 

3.2

5.9

 

 

 

 

Spacing Criteria

 

 

 

 

 

 

 

 

 

 

45

1290

 

912

 

0-180

5240

 

54.6

100.0

 

 

 

 

 

 

 

=1.4

=1.2

 

 

 

 

 

 

 

 

 

 

1350

 

 

 

 

 

55

706

 

565

 

 

 

 

 

 

 

 

 

 

 

Efficiency=55.0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

438

 

266

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

 

 

 

 

 

 

 

 

75

381

 

139

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

359

 

71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

283

 

7

 

 

 

 

 

 

 

 

 

 

 

2250

 

 

 

 

 

 

Coefficient of Utilization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

 

 

 

 

70%

 

 

50%

30%

 

 

10%

0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rw

70

50

30

 

10

50

30

10

50

10

50

10

50

10

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

47

47

47

 

47

46

46

46

43

43

41

41

39

39

38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

44

42

40

 

39

41

39

38

39

36

37

35

35

34

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

40

37

35

 

33

36

34

32

35

31

33

30

32

29

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

37

34

31

 

29

33

30

28

31

27

30

27

29

26

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

35

31

27

 

25

30

27

25

29

24

27

24

26

23

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

32

28

24

 

22

27

24

22

26

21

25

21

24

21

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

30

25

22

 

20

25

22

20

24

19

23

19

22

19

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

28

23

20

 

18

23

20

18

22

17

21

17

20

17

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

26

21

18

 

16

21

18

16

20

15

19

15

19

15

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

24

19

16

 

14

19

16

14

18

14

18

14

17

13

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

23

18

15

 

13

17

14

13

17

12

16

12

16

12

11

rc=Ceiling reflectance, rw=W all reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance.

ORDERING INFORMATION

Specifications and Dimensions subject to change without notice.

ADC041733

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

04/09/2007 11:12:18 AM

Page 2
Image 2
Cooper Lighting FWSCR-340-120, Photometrics, Candlepower Distribution, Zonal Lumen Summary, =1.4, Ordering Information