FWSCR

PHOTOMETRICS

Candlepower Distribution

 

 

 

 

 

 

Candlepower

 

 

 

Zonal Lumen Summary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

Lumens

 

%Lamp

%Luminaire

 

 

 

 

Test No. 4870

 

Deg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

2107

 

2107

 

 

0-30

1641

 

17.1

31.3

 

 

 

 

 

FWSCR-340-120

 

 

 

 

 

 

 

 

450

 

5

2111

 

2107

 

 

0-40

2765

 

28.8

52.8

 

 

 

 

Lamp=(3) F40T12RS/

 

 

 

 

 

 

 

15

2123

 

2044

 

 

0-60

4137

 

43.1

79.0

 

 

 

 

 

 

 

 

WW

 

 

 

 

 

 

 

 

 

 

 

 

 

25

2105

 

1876

 

 

0-90

4933

 

51.4

94.1

 

 

 

 

900

Lumens=3200

 

 

 

 

 

 

 

 

 

35

1928

 

1567

 

 

90-180

307

 

3.2

5.9

 

 

 

 

Spacing Criteria

 

 

 

 

 

 

 

 

 

 

45

1290

 

912

 

0-180

5240

 

54.6

100.0

 

 

 

 

 

 

 

=1.4

=1.2

 

 

 

 

 

 

 

 

 

 

1350

 

 

 

 

 

55

706

 

565

 

 

 

 

 

 

 

 

 

 

 

Efficiency=55.0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

438

 

266

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

 

 

 

 

 

 

 

 

75

381

 

139

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

359

 

71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

283

 

7

 

 

 

 

 

 

 

 

 

 

 

2250

 

 

 

 

 

 

Coefficient of Utilization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

 

 

 

 

70%

 

 

50%

30%

 

 

10%

0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rw

70

50

30

 

10

50

30

10

50

10

50

10

50

10

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

47

47

47

 

47

46

46

46

43

43

41

41

39

39

38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

44

42

40

 

39

41

39

38

39

36

37

35

35

34

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

40

37

35

 

33

36

34

32

35

31

33

30

32

29

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

37

34

31

 

29

33

30

28

31

27

30

27

29

26

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

35

31

27

 

25

30

27

25

29

24

27

24

26

23

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

32

28

24

 

22

27

24

22

26

21

25

21

24

21

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

30

25

22

 

20

25

22

20

24

19

23

19

22

19

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

28

23

20

 

18

23

20

18

22

17

21

17

20

17

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

26

21

18

 

16

21

18

16

20

15

19

15

19

15

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

24

19

16

 

14

19

16

14

18

14

18

14

17

13

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

23

18

15

 

13

17

14

13

17

12

16

12

16

12

11

rc=Ceiling reflectance, rw=W all reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance.

ORDERING INFORMATION

Specifications and Dimensions subject to change without notice.

ADC041733

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

04/09/2007 11:12:18 AM

Page 2
Image 2
Cooper Lighting specifications FWSCR-340-120, Photometrics, Ordering Information

FWSCR specifications

Cooper Lighting's FWSCR is an innovative outdoor lighting solution designed to enhance safety and visibility in a variety of environments. This advanced floodlight is particularly popular among municipalities, commercial properties, and industrial facilities due to its impressive performance and energy efficiency.

One of the standout features of the FWSCR is its use of LED technology. The LED sources provide a longer lifespan compared to traditional lighting options, often lasting over 50,000 hours. This not only reduces the frequency of replacements but also significantly lowers maintenance costs. The integration of LED technology ensures a bright, clear light that improves visibility while consuming less power, aligning with sustainability goals that many organizations are pursuing.

Another notable technology incorporated into the FWSCR is its precision optical design, which allows for optimal light distribution. This ensures that the light is evenly spread across the designated area, minimizing dark spots and enhancing overall safety. The fixture is available in multiple lumen output options, enabling users to select the ideal intensity depending on the specific application, whether it be sports fields, parking lots, or building facades.

The FWSCR also boasts a robust construction that is resistant to harsh outdoor conditions. Its durable housing protects from water, dust, and corrosion, making it suitable for use in various climates. The fixture's IP66 rating guarantees that it withstands rain and moisture exposure, further increasing its utility in outdoor settings.

In addition to these features, energy efficiency is at the core of the FWSCR's design. The fixture not only meets but often exceeds the stringent energy codes, making it a smart choice for those looking to reduce their carbon footprint. The incorporation of smart lighting technologies, such as motion sensors and dimming capabilities, can further enhance energy savings by adjusting lighting levels based on occupancy or time of day.

Overall, Cooper Lighting's FWSCR floodlight emerges as a leading choice in outdoor lighting solutions, providing a blend of efficiency, durability, and advanced technology. Its design is tailored to meet the needs of various applications while ensuring safety, performance, and sustainability. Whether illuminating a commercial space or enhancing security in public areas, the FWSCR stands out as an exceptional lighting option.