HCS

PHOTOMETRICS

 

 

 

 

 

 

 

 

Candlepower Distribution

Candlepower

 

Zonal Lumen Summary

 

 

Test No. 6580.0

Deg.

 

 

Zone

Lumens

%Lamp

%Luminaire

 

0

719

719

0-30

605

6.4

15.1

 

HCS-100S-DUAL

 

5

739

715

0-40

1003

10.6

25.1

700

Lamp=S54 (LU100/MED)

15

805

649

0-60

2636

27.8

65.8

 

No. Lamps=1

 

25

729

581

0-90

3737

39.3

93.3

 

Lumens=9500

1400

35

763

435

90-180

268

2.8

6.7

Spacing Criteria

 

45

1178

433

0-180

4005

42.2

100.0

 

= 2.4 =1.1

 

55

2354

389

 

 

 

 

2100

Efficiency=42.0%

 

 

 

 

 

 

65

1231

232

 

 

 

 

2800

 

75

345

91

 

 

 

 

 

85

84

37

 

 

 

 

 

 

 

 

 

 

 

 

90

73

36

 

 

 

 

3500

 

 

 

 

 

 

 

 

Coefficient of Utilization

rc

 

 

 

80%

 

 

70%

 

 

50%

 

30%

 

10%

0%

rw

 

70

50

30

10

50

30

10

50

10

50

10

50

10

0

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

50

50

50

50

48

48

48

45

45

43

43

40

40

39

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

45

43

41

39

42

40

38

39

37

37

35

35

34

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

41

37

34

31

36

33

31

34

30

32

29

30

28

36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

37

32

28

25

31

28

25

29

24

28

23

26

23

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

33

28

24

21

27

23

20

25

20

24

19

23

19

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

30

24

20

16

23

19

16

22

16

21

15

19

15

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

27

21

16

13

20

16

13

19

13

18

13

17

12

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

24

18

14

11

18

14

11

17

11

16

10

15

10

09

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

22

16

12

09

16

12

09

15

09

14

09

13

08

08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

20

14

10

08

14

10

08

13

07

12

07

12

07

06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

19

13

09

07

12

09

07

12

06

11

06

11

06

05

rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance.

ORDERING INFORMATION

Specifications and Dimensions subject to change without notice.

ADC041544

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

04/18/2007 10:30:09 AM

Page 2
Image 2
Cooper Lighting HCS specifications Photometrics, Candlepower Distribution Zonal Lumen Summary, Coefficient of Utilization

HCS specifications

Cooper Lighting HCS, now part of Signify, has established itself as a leader in innovative lighting solutions, especially catering to industrial and commercial applications. The HCS product line is renowned for its robust design and advanced technology, specifically crafted to meet the diverse needs of various environments, ranging from warehouses to retail spaces.

One of the standout features of Cooper Lighting HCS is its superior energy efficiency. The use of LED technology significantly reduces energy consumption compared to traditional lighting solutions. This not only leads to lower utility bills but also contributes to sustainability goals by minimizing carbon footprints. In addition, many HCS products are equipped with smart controls that allow for enhanced energy management. These controls enable users to adjust lighting based on occupancy levels, natural light availability, and specific task requirements, further optimizing energy usage.

Another key characteristic of the HCS line is its durability and longevity. Designed to withstand harsh conditions, HCS fixtures are built with rugged materials that resist impact, dust, and moisture. This makes them suitable for a variety of applications, including those in industrial settings where reliability is paramount. The extended lifespan of LED components ensures that maintenance costs are kept to a minimum, providing a cost-effective lighting solution over time.

Technologically, Cooper Lighting HCS stands out for its incorporation of sophisticated lighting controls. The integration of intelligent sensors and IoT capabilities allows for real-time monitoring and management, accommodating the evolving needs of modern facilities. These technologies facilitate easy integration with existing building management systems, ensuring seamless operation and enhanced control.

Versatility is another defining trait of the HCS line. With a broad range of styles, lumen outputs, and mounting options, Cooper Lighting HCS can cater to various installation spaces and aesthetic preferences. Whether it is high bay lighting for warehouses or sleek fixtures for retail environments, HCS products offer customizable solutions that enhance both functionality and ambiance.

In summary, Cooper Lighting HCS represents the pinnacle of modern lighting technology, emphasizing energy efficiency, durability, advanced controls, and versatility. With a commitment to innovation and sustainability, Cooper Lighting HCS continues to be a frontrunner in providing lighting solutions that meet the demands of today’s facilities and contribute to a greener future.