L3232E-LVR3232SC
x Average Table Fc Level

PH OT O ME TRICS

L 32 32E

Test No. H20052

Sin gle Fixture

3'

From

Wa ll

 

 

 

Mu lt ipl e Fi xt ures

3' Dis tance

From

Wa ll

 

 

 

 

 

L3232E-LVR3232SC

DD

Distance From Fixture Along Wall

6'

 

DD

–––––– 3' ––––––

 

Spacing Between Fixtures

 

–––––– 6' ––––––

Specular Louver

1'

2'

3'

4'

5'

 

–––––– 4' –––––

–––––– 5' –––––

 

 

 

 

 

 

 

 

 

 

 

 

189

186

189

153

133

153

136

95

136

127

66

127

1

120

100

63

33

17

8

4

1

 

Lamp=(2) 32W TTT

 

 

 

 

 

 

 

 

 

 

 

 

 

160

160

160

126

118

126

109

88

109

99

68

99

2

88

77

54

33

18

10

5

2

 

Lumens=2,400

 

 

 

 

 

 

 

 

 

 

 

 

 

115

118

115

93

91

93

77

70

77

68

55

68

3

56

52

39

27

17

10

6

3

 

45° Aiming Angle

 

 

 

 

 

 

 

 

 

 

 

 

 

77

80

77

63

63

63

52

51

52

45

41

45

4

33

31

26

19

13

9

6

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52

54

52

43

44

43

36

36

36

31

30

31

 

5

21

20

17

13

10

7

5

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

38

37

31

31

31

26

26

26

23

22

23

 

6

14

13

11

9

7

6

4

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

27

26

22

23

22

19

19

19

17

17

17

 

7

9

9

8

7

6

4

4

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

19

19

16

17

16

14

15

14

13

13

13

 

8

6

6

6

5

4

4

3

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

15

14

13

13

13

11

11

11

10

10

10

 

9

4

4

4

4

3

3

2

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

11

11

10

10

10

9

9

9

8

8

8

 

10

3

3

3

3

3

2

2

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S in gle Fixture

4'

From

Wall

 

 

 

Multi pl e Fi xt ur es 4' Dista nce

From

Wall

 

 

 

 

 

 

 

Distance From Fixture Along Wall

 

 

 

 

–––––– 4' ––––––

 

Spacing Between Fixtures

 

–––––– 7' ––––––

DD

1'

2'

3'

4'

5'

6'

 

DD

 

–––––– 5' –––––

–––––– 6' –––––

 

 

69

62

46

30

18

10

6

 

1

 

106

105

106

91

81

91

82

62

82

76

47

76

1

 

 

 

61

55

43

29

19

12

7

 

2

 

102

100

102

85

78

85

76

62

76

70

49

70

2

 

 

 

45

42

34

25

18

12

8

 

3

 

84

84

84

70

68

70

60

54

60

55

44

55

3

 

 

 

31

30

26

20

15

11

7

 

4

 

65

66

65

55

54

55

47

45

47

42

37

42

4

 

 

 

21

21

18

15

12

9

7

 

5

 

48

50

48

41

41

41

35

35

35

31

29

31

5

 

 

 

15

14

13

11

9

7

5

 

6

 

36

37

36

31

31

31

27

27

27

24

23

24

6

 

 

 

10

10

9

8

7

6

4

 

7

 

27

28

27

23

24

23

20

21

20

18

18

18

7

 

 

 

8

7

7

6

5

4

4

 

8

 

21

21

21

18

19

18

16

16

16

14

14

14

8

 

 

 

6

5

5

5

4

4

3

 

9

 

16

16

16

14

14

14

13

13

13

11

11

11

9

 

 

 

4

4

4

4

3

3

2

10

 

12

13

12

11

11

11

10

10

10

9

9

9

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test No. H20054

Sin gle Fixture

3'

From

Wa ll

 

 

 

Mu lti pl e Fi xt ur es 3' Dista nce

From

Wall

 

 

 

 

 

L3232E-LVR3232P

 

DD

Distance From Fixture Along Wall

6'

 

DD

–––––– 3' ––––––

 

Spacing Between Fixtures

 

–––––– 6' ––––––

White Louver

 

1'

2'

3'

4'

5'

 

–––––– 4' –––––

–––––– 5' –––––

 

 

 

 

 

 

 

 

 

 

 

 

 

178

168

178

147

118

147

133

83

133

127

56

127

Lamp=(2) 32W TTT

 

1

120

96

56

27

13

6

3

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

92

77

50

29

15

8

4

2

 

155

149

155

123

109

123

108

80

108

100

60

100

Lumens=2,400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

57

51

37

24

15

8

5

3

 

109

110

109

88

83

88

74

63

74

67

49

67

45° Aiming Angle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

35

32

25

18

12

7

4

4

 

74

76

74

61

59

61

50

47

50

44

37

44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

22

20

17

13

9

6

4

5

 

51

52

51

42

42

42

35

34

35

30

29

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

14

14

12

9

7

5

4

6

 

36

37

36

30

30

30

26

25

26

22

21

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

9

9

8

7

5

4

4

7

 

26

26

26

22

22

22

18

18

18

16

16

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

6

6

6

5

4

3

3

8

 

19

19

19

16

16

16

14

14

14

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

4

4

4

4

3

3

2

9

 

14

14

14

12

12

12

10

11

10

9

9

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

3

3

3

3

2

2

1

10

 

10

11

10

9

9

9

8

8

8

7

7

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sin gle Fixture

4'

From

Wa ll

 

 

 

 

Mu lt ipl e Fixture s 4' Distanc

e From

Wall

 

 

 

 

 

 

 

 

 

Distance From Fixture Along Wall

 

 

 

 

 

–––––– 4' ––––––

 

Spacing Between Fixtures

 

–––––– 7' ––––––

 

 

DD

1'

2'

3'

4'

5'

6'

 

 

DD

 

–––––– 5' –––––

–––––– 6' ––––––

 

 

 

 

67

59

42

26

14

8

5

1

 

98

92

98

84

70

84

77

53

77

73

40

73

 

1

 

 

 

 

65

56

41

27

17

9

6

 

2

 

100

93

100

84

72

84

76

56

76

71

44

71

 

2

 

 

 

 

46

42

33

23

16

10

6

 

3

 

81

78

81

67

63

67

59

50

59

54

40

54

 

3

 

 

 

 

32

31

25

19

13

10

6

 

4

 

62

62

62

52

50

52

45

41

45

40

33

40

 

4

 

 

 

 

22

21

18

14

11

8

6

 

5

 

46

47

46

39

38

39

34

32

34

30

27

30

 

5

 

 

 

 

15

15

13

11

8

6

5

 

6

 

35

35

35

30

29

30

26

25

26

23

21

23

 

6

 

 

 

 

11

11

9

8

7

5

4

 

7

 

26

27

26

22

23

22

20

20

20

18

17

18

 

7

 

 

 

 

8

8

7

6

5

4

3

 

8

 

20

21

20

18

18

18

15

15

15

14

13

14

 

8

 

 

 

 

6

6

5

5

4

3

3

 

9

 

16

16

16

14

14

14

12

12

12

11

11

11

 

9

 

 

 

 

4

4

4

4

3

3

2

 

10

 

12

13

12

11

11

11

10

10

10

9

9

9

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test No. H20053

 

 

 

Si ngle

Fi xture

3'

Fro m Wa ll

 

L3232E-LVR3232MB

DD

 

Distance From Fixture Along Wall

6'

Black Louver

 

1'

2'

3'

4'

5'

 

 

 

 

 

 

 

 

 

 

1

103

78

42

19

8

3

1

Lamp=(2) 32W TTT

 

 

 

 

 

 

 

 

 

 

2

81

65

40

22

10

5

2

Lumens=2,400

 

 

 

 

 

 

 

 

 

 

3

51

43

30

19

11

5

3

45° Aiming Angle

 

 

 

 

 

 

 

 

 

 

4

31

27

21

14

9

5

3

 

 

 

 

 

 

 

 

 

 

 

 

5

19

17

14

10

7

5

3

 

 

 

 

 

 

 

 

 

 

 

 

6

12

11

9

7

5

4

3

 

 

 

 

 

 

 

 

 

 

 

 

7

8

8

7

5

4

3

2

 

 

 

 

 

 

 

 

 

 

 

 

8

5

5

5

4

3

2

2

 

 

 

 

 

 

 

 

 

 

 

 

9

4

4

3

3

2

2

2

 

 

 

 

 

 

 

 

 

 

 

 

10

3

3

2

2

2

2

1

 

 

 

 

 

 

 

 

 

 

 

Sin gle Fi xture

4'

From

Wall

 

 

 

 

Distance From Fixture Along Wall

 

DD

1'

2'

3'

4'

5'

6'

 

 

57

48

32

18

9

5

2

1

 

 

56

47

33

21

12

6

3

2

 

 

41

36

28

19

12

7

4

3

 

 

29

26

21

15

11

8

4

4

 

 

19

18

15

12

8

6

4

5

 

 

14

13

11

9

7

5

4

6

 

 

10

9

8

7

5

4

3

7

 

 

7

7

6

5

4

3

3

8

 

 

5

5

4

4

3

3

2

9

 

 

4

4

3

3

3

2

2

10

 

 

 

 

 

 

 

 

 

Notes:

Illuminance values for multiple fixtures are based upon the center two units of a four unit array. Footcandle values are centerline of fixtures and centered between fixtures. 1 footcandle = 10.76 lux. 1 foot(') = 304.8mm.

Footcandle Multipliers for 50W (4,000 lumens) = 1.27, for 55W (4,800 lumens) = 1.52

Illuminance values are cosine corrected initial values with no contribution from inter reflections from other room surfaces. Total illuminationmay increase from contributions from other surfaces.

Changing fixture spacing will affect illuminance level.

Existing Spacing

New Spacing

Mu lti pl e Fi xt ur es 3' Dista nce

From

Wall

 

 

 

 

 

 

 

–––––– 3' ––––––

 

Spacing Between Fixtures

 

–––––– 6' ––––––

DD

–––––– 4' ––––––

–––––– 5' –––––

1

 

141

127

141

118

86

118

109

58

109

105

37

105

 

 

128

119

128

102

85

102

91

61

91

86

44

86

2

 

 

 

91

89

91

73

66

73

61

49

61

56

38

56

3

 

 

 

62

62

62

50

47

50

42

37

42

37

29

37

4

 

 

 

42

43

42

34

34

34

29

27

29

25

22

25

5

 

 

 

30

30

30

24

24

24

21

20

21

18

16

18

6

 

 

 

21

21

21

17

18

17

15

15

15

13

12

13

7

 

 

 

15

15

15

13

13

13

11

11

11

9

9

9

8

 

 

 

11

11

11

10

10

10

8

8

8

7

7

7

9

 

 

 

8

9

8

7

7

7

6

6

6

6

6

6

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mu lt ipl e Fi xt ures

4' Dis tance

From

Wa ll

 

 

 

 

 

 

 

–––––– 4' ––––––

 

Spacing Between Fixtures

 

–––––– 7' ––––––

DD

–––––– 5' ––––––

–––––– 6' ––––––

1

 

76

68

76

67

51

67

62

37

62

59

26

59

 

 

80

73

80

68

55

68

62

42

62

59

32

59

2

 

 

 

67

63

67

56

49

56

49

38

49

46

31

46

3

 

 

 

51

50

51

43

40

43

37

32

37

34

26

34

4

 

 

 

38

38

38

32

31

32

28

26

28

25

21

25

5

 

 

 

29

29

29

24

24

24

21

20

21

19

17

19

6

 

 

 

22

22

22

18

19

18

16

16

16

14

13

14

7

 

 

 

17

17

17

14

14

14

13

12

13

11

11

11

8

 

 

 

13

13

13

11

11

11

10

10

10

9

8

9

9

 

 

 

10

10

10

9

9

9

8

8

8

7

7

7

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Specifications and Dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.468.4800 FAX 770 468.4801 ADV990356 Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049

Page 2
Image 2
Cooper Lighting manual L3232E-LVR3232SC, Specular Louver, L3232E-LVR3232P, White Louver, L3232E-LVR3232MB, Black Louver