Cooper Lighting MCL5 instruction manual Installing the bulb, Assembling your fixture, How to use

Models: MCL5

1 13
Download 13 pages 10.18 Kb
Page 3
Image 3

MCL35 325-1577.qxd 8/23/06 3:28 PM Page 3

Do not operate the unit with a missing or damaged wire safety guard, or safety glass lens (lamp containment / UV filter).

Do not direct the light at persons or look directly at lighted fixture.

Use only with a 35 watt or smaller bulb. Installing a bulb of a higher wattage could create a fire hazard. Use of a higher wattage bulb will void the warranty.

Never touch the bulb with your bare hands. Oil from your skin can cause pre mature failure. Always handle the bulb with gloves or a soft cloth.withple Ima

If lens is replaced, use only a diffused tempered safety glass of equal thickness.

Disassembly of your fixture will void the warranty.

NOTE: When using outdoor use portable lamps, basic safety precautions should always be followed to reduce the risk of fire, electric shock and personal injury, including the following...

Use only with three wire extension cords that have three-prong grounding plugs and that are suitable for outdoor use, such as cords marked SW, SW-A, SOW, SOW-A, STW, STW-A, STOW, STOW-A, SJW, SJW-A, SJOW, SJOW-A, SJTW-A, SJTOW, SJTOW-A and grounding receptacles that accept a three-prong plug. When the fixture is used in wet locations, Ground Fault Circuit Interruption (GFCI) protection must be provided on the circuit(s) or out let(s) to be used. Receptacles are available having built-in GFCI protection and are able to be used for this measure of safety.

NOTE: Deviation from the assembly instructions may result in a risk of fire or electric shock.

SAVE THESE INSTRUCTIONS.

Installing the bulb

Step 1: Remove the lens cover by twisting it one-half turn counter-clockwise.

Step 2: Using gloves or a soft cloth, gently plug bulb into housing.

NOTE: Align two pins located at the end of the bulb with two small holes in the center of housing, and press until firmly seated.

Step 3: Replace the lens (making sure the gasket is in place) by aligning the notches on the housing with the cover and pressing until seated. Twist one-half turn clockwise until tight.

Assembling your fixture

Squeeze sides of wire guard while positioning it over the glass lens and release sides so that the ends of the wire guard slip into open slots in lens cover.

How to use

Attach light near work surface, using spring clamp on bottom of light or hang the light with vinyl coated hook attached to the side of the clamp. Plug the light into a 3 wire grounded extension cord. Plug the extension cord into any standard grounded 120 Volt receptacle. Press switch to turn on light. Press opposite side to turn the light off.

NOTE: The power cord length of this fixture was selected to reduce safety hazards that may occur with a longer power cord.