Cooper Lighting specifications Fail-Safe, MPR MPR2, Catalog #, Project Comments, Prepared by

Models: MPR MPR2

1 2
Download 2 pages 62.28 Kb
Page 1
Image 1
Catalog #

DESCRIPTION

Fail-Safe's hospital patient room of the future - the MPR removes lighting elements from walls incorporating them into a multi-compartment ceiling fixture. Sections provide independent task illumination: patient reading light using (1) 40W biaxial lamp puts the light at the head of the bed for patient use; ambient room light using (2) 40W biaxial lamps provides soft illumi- nation via perforated wings while shielding direct source glare; examination light uses (3) 40W biaxial lamps and focuses high intensity illumination to torso for maximum patient appraisal with minimal wattage consumption. The system is designed for 1, 2, or 3 feeds potentially reducing the overall installed cost. Also available for 50W biaxial lamps.

SPECIFICATION FEATURES

Catalog #

Project

Comments

Prepared by

FAIL-SAFE®

TypeDate
Mounting

Recessed Grid or Flange, Ceiling Mount (supported from above)

Lamps

(By Others)

Ballast

Standard, Class P, CBM/ETL Ballast, (3) circuit wiring.

Housing

Die-formed, 20 ga. cold rolled steel.

Features

-20 gauge CRS housing is formed fabricated for maximum strength and stability.

-Each compartment is designed to provide a specific illumination function while allowing for commonality of branch circuit feeding.

-High efficiency biaxial lamps provide excellent color rendering ability and high lumen output for nominal wattage draw.

Finish

Low gloss, electrostatically applied, baked white powder polyester-finish.

Shielding

(READING LIGHT) Die formed lamp shield.

(AMBIENT LIGHT) Formed perforated metal.

(EXAM LIGHT) Pattern 12 Acrylic Ribbed lens.

Labels

U.L. Listed, C.S.A. Certified.

3 COMPARTMENT DIMENSIONS

 

 

2 COMPARTMENT MOUNTING

6” [153mm]

24” [610mm]

18” [457mm]

 

 

ø .875

 

 

 

 

 

 

 

 

 

(4) 5/16" Mounting Holes Knockout

 

 

 

6 1/4”

 

 

 

 

 

[159mm]

 

 

READING

 

EXAM

 

 

20 3/8"

AMBIENT LIGHT

 

 

 

LIGHT

 

 

 

LIGHT

 

 

 

 

 

 

 

6” [153mm] MAX FROM WALL

 

 

 

 

 

 

 

 

48” [1219mm]

 

 

44 1/8"

 

 

24” [610mm] wide

 

 

 

 

 

 

 

 

3 COMPARTMENT MOUNTING

 

 

2 COMPARTMENT DIMENSIONS

 

 

 

 

 

24"

 

 

 

 

 

Runs Ambient Section

 

 

 

 

 

Runs Exam Section

 

 

 

 

 

6 1/4"

 

 

 

 

24" x 48" C to C

Exam Light

 

 

 

6”

 

 

 

 

 

 

 

 

 

max.

 

 

MPR

MPR2

AMBIENT/DIRECT

Multi-Compartment

Patient Room

Recessed Luminaire

2' x 4' Fluorescent Grid

2' x 4' Fluorescent Flange

E N E R G Y D A TA

Input Watts:

Electronic Ballasts and

Standard Lamps

(6)40W Biaxial Fluorescents: 204W

(6)50W Biaxial Fluorescents: 264W

ORDERING INFORMATION

S A M P L E N U M B E R : M P R 2 - G - 6 4 0 B X - 1 2 0 - E B X 3

Product Family

MPR2= 2 Compartment

Medical Patient

Room Recessed

Luminaire Exam

&Ambient Section

MPR = Standard 3

Compartment

Medical Patient

Room Recessed

Luminaire

Reading, Exam

&Ambient Section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ceiling

 

Voltage

 

 

 

 

 

 

Ambient Options

 

120=120V

 

 

 

 

 

 

If no option is chosen, then

Type

 

 

 

 

 

 

 

 

277=277V

 

 

 

 

 

 

Standard 2 Basket Ambient

G=Grid

 

 

 

 

 

 

 

 

347=347V

 

 

 

 

 

 

will be provided.

F=Flange

 

 

 

 

 

 

 

 

 

 

 

 

UNV=120V through 277V

 

 

 

SCPB=Single Perf Basket Centered

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSCB=Single Sealed Lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp Type

 

 

 

Ballast

 

 

 

 

 

Biaxial Fluorescents

EBX3=(3) Ballasts for use with biaxial lamps

640BX=(6) 40W Lamps

EBX4=(4) Ballasts for use with biaxial lamps 1

 

 

 

 

 

 

 

 

650BX=(6) 50W Lamps

 

 

 

 

 

 

 

 

Options

EBP=Emergency Battery Pack FNL=Fluorescent Night Light

(Lamp by others) GLR=Fuse and Holder

RIF=Radio Interference Filter

LVRELAY=Low Voltage Relay

Accessories (order

separately)

MPR-GGO-1=Full

Clear Poly Lens

Door. No Acrylic

Over Exam Hinged Door 2

MPR-GGD-2=Two

Compartment MPR

(Lens Poly and Acrylic) 2

MPR-GGD-3=Three

Compartment MPR

Hinged Door (Lens

Poly and Acrylic) 2

Specifications and Dimensions subject to change without notice.

ADC080701

Consult your representative for additional options and finishes.

03/18/2008 6:56:59 AM

Page 1
Image 1
Cooper Lighting specifications Fail-Safe, MPR MPR2, Catalog #, Project Comments, Prepared by, Type, Date, Mounting