SURFACE
COOPER LIGHTING - METALUX®
P410 SERIES
4 ' o r 8 ' S u r f a c e 2 L a m p s
S p e c i a l L o u v e r
L O W P R O F I L E L I N E A R L I G H T I N G S Y S T E M
• Die formed housing of |
code gauge prime cold |
rolled steel |
D E S C R I P T I O N
The P410 linear lighting system has been designed to provide an attractive, energy efficient, and low brightness lighting system for retail merchandising and commercial environments utilizing a
O R D E R I N G I N F O R M AT I O N
D I M E N S I O N S
P 4 1 0 W h i t e L o u v e r
P 4 1 0 P a r a b o l i c L o u v e r
NOMINAL LENGTH | A | B |
4' | 10" (254mm) |
• | Decorative injection |
| molded white end plates(3) |
• | Louver positively secured |
S A M P L E N U M B E R : P 4 1 0 - 2 3 2 - T B W - 1 2 0 V - E B 8 1 - U
by integral spring steel |
clips |
• Surface, stem or cable |
mounting accessories |
• Low profile housing design |
for architectural appeal |
• Utilizes energy efficient |
ballasts and dedicated T8 |
lamp sources |
• A variety of optics |
include a thin blade |
white baffled louver and |
specular/mirrored or semi- |
specular/low iridescent |
parabolic louver |
Tandem
Blank=4' Length 8T=8' Length
P410=Series
Number of Lamps
2lamps
(Not Included)
Wattage (Length)
32=32W T8 (48")
TBW=Thin Blade White Baffle
PLMI=Silver Parabolic Louver,
Specular Mirrored (Low Iridescent)
PLI=Silver Parabolic Louver, Semi-
Specular/ (Low Iridescent)
Voltage (1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage
Options
GL=Single Element Fuse GM=Double Element Fuse Emergency - for EM installed, see EM options table
Options | Packaging |
(See Options Section) | U=Unit Pack |
UPL=15% Uplight |
|
Slots in Housing |
|
Ballast Type (1)
ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%
No. of Ballast 1, 2 or 3
EB8 = T8 Electronic Instant Start. Total Harmonic Distortion < 10%
No. of Ballast 1, 2 or 3
EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total Harmonic
No. of | Distortion < 20% | |
Ballast | ||
| ||
1, 2 or 3 |
|
(For complete details on generic or to specify manufacturer’s ballast see pg. 469)
• Durable, baked white |
polyester powder finish |
• Optional slots in fixture |
sides for 15% uplight |
• UL/CUL Listed. Suitable for |
damp locations. |
NOTES: (1)Products also available in
(3)2 endplates provided with each fixture.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
416
I N S TA L L AT I O N D ATA
STEM | CABLE | SURFACE |
MOUNTING | MOUNTING | MOUNTING |
|
|
|
|
|
|