HBO

PHOTOMETRICS

3HBO-654T5-G-UPL

(2) Electronic Ballasts

(6)54W T5 lamps

4500 lumens

Spacing criterion:

(II)1.3 x mounting height, () 1.4 x mounting height Efficiency 84.5% Test Report: 18450

Candela

Angle

Along II

45°

Across

0

8100

8100

8100

5

8068

8072

8068

10

7983

7974

7954

15

7836

7799

7799

20

7639

7585

7561

25

7381

7303

7250

30

7066

6943

6870

35

6710

6522

6412

40

6293

6019

5777

45

5843

5450

5120

50

5327

4734

3794

55

4791

3973

2386

60

4195

2747

1630

65

3539

1556

1224

70

2842

1066

910

75

2043

717

656

80

1213

461

464

85

443

255

222

90

40

45

27

3HBO-654T5-UPL

(2) Electronic Ballasts

(6)54W T5 lamps

4500 lumens

Spacing criterion:

(II)1.3 x mounting height, () 1.1 x mounting height Efficiency 91.7% Test Report: 18451

Candela

Angle

Along II

45°

Across

0

13864

13864

13864

5

13828

13980

14046

10

13628

13685

13227

15

13309

12830

12699

20

12859

12269

11308

25

12282

11197

9599

30

11599

9618

7544

35

10796

8039

6051

40

9900

6157

4211

45

8911

4862

2972

50

7840

3229

1834

55

6718

2189

602

60

5541

1147

74

65

4317

189

50

70

3123

50

51

75

1994

50

59

80

1020

50

51

85

296

46

46

90

27

21

21

C o effi c i e n t s of Utilization

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

99

99

99

99

96

96

96

96

91

91

91

86

86

86

81

81

81

79

 

1

 

91

88

84

81

88

85

82

79

81

78

76

76

74

73

72

71

69

67

 

2

 

83

77

72

67

81

75

70

66

71

67

63

67

64

61

64

61

59

57

 

3

 

76

68

62

56

74

66

60

55

63

58

54

60

56

52

57

54

51

49

 

4

 

70

61

53

48

68

59

52

47

56

51

46

54

49

45

51

47

44

42

 

5

 

65

54

47

42

62

53

46

41

51

45

40

48

43

39

46

42

38

36

 

6

 

60

49

42

36

58

48

41

36

46

40

35

44

39

35

42

37

34

32

 

7

 

55

44

37

32

54

43

37

32

42

36

31

40

35

31

38

34

30

28

 

8

 

52

40

34

29

50

40

33

28

38

32

28

37

31

27

35

31

27

25

 

9

 

48

37

30

26

47

36

30

26

35

29

25

34

29

25

33

28

24

23

 

10

 

45

34

28

23

44

34

27

23

32

27

23

31

26

23

30

26

22

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zonal Lumen Summary

Luminance Data

 

 

 

 

 

 

 

 

Average

Average

Average

Zone

Lumens

%Lamp

%Fixture

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

0-30

6338

23.5

27.8

 

 

45

11108

10361

9732

0-40

10422

38.6

45.7

 

 

55

11229

9310

5591

0-60

17906

66.3

78.5

 

 

65

11258

4950

3894

0-90

21315

78.9

93.4

 

 

75

10611

3726

3407

0-180

22821

84.5

100.0

 

 

85

6828

3934

3418

 

 

 

 

 

ORDERING INFORMATION

Coefficients of Utilization

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

108

108

108

108

105

105

105

105

99

99

99

94

94

94

89

89

89

87

 

1

 

101 98

95

92

98

95

92

90

91

88

86

86

85

83

82

81

80

78

 

2

 

94

88

83

79

91

86

81

78

82

78

75

78

75

73

75

73

71

69

 

3

 

87

79

73

68

85

78

72

68

74

70

66

71

67

64

69

65

63

61

 

4

 

81

72

65

60

79

70

64

59

68

62

58

65

61

57

63

59

56

54

 

5

 

75

65

58

53

73

64

58

53

62

56

52

60

55

51

58

53

50

48

 

6

 

70

60

53

48

68

59

52

47

57

51

47

55

50

46

53

49

45

43

 

7

 

66

55

48

43

64

54

47

43

52

46

42

51

45

42

49

44

41

39

 

8

 

61

51

44

39

60

50

43

39

48

42

38

47

42

38

46

41

37

36

 

9

 

58

47

40

36

56

46

40

35

45

39

35

44

38

35

42

38

34

33

 

10

 

54

44

37

33

53

43

37

33

42

36

32

41

36

32

40

35

32

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zonal Lumen Summary

Luminance Data

 

 

 

 

 

 

 

 

Average

Average

Average

Zone

Lumens

%Lamp

%Fixture

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

0-30

10007

37.1

40.4

 

 

45

16940

9242

5650

0-40

15138

56.1

61.1

 

 

55

15744

5131

1412

0-60

21858

81.0

88.3

 

 

65

13730

602

158

0-90

23497

87.0

94.9

 

 

75

10356

258

304

0-180

24766

91.7

100.0

 

 

85

4571

714

714

 

 

 

 

 

S A M P L E N U M B E R : 3 HBOT- 854T5 - UNV- EBT2 - UPL- U

Width

3=32" wide

Series

HBO=High Bay Open

Body

HBOT=High Bay Open

Top Version

No. of Lamps

8=8 Lamps

Lamp Type

54T5=54W T5HO (4') Lamp

Distribution

Blank=Medium (Specular Aluminum) G=Wide (White Painted)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage(2)

 

 

 

BallastType

 

UNV=Universal

 

 

 

T5 Systems

 

120/277 Voltage

 

 

 

EBT =T5 Linear Electronic Program Rapid Start

(3)

UNC=Universal

 

 

 

 

 

 

 

 

 

 

 

 

Total Harmonic Distortion < 10%

 

347/480 Voltage

 

 

 

 

 

 

 

 

 

(T5 linear only)(6)

 

 

 

 

No. of Ballast

 

120V=120 Volt

 

 

 

 

2, 3 or 4

 

 

 

 

EHT

 

 

=T5 Electronic Program Start High Ambient(6)

277V=277 Volt

 

 

 

 

 

347V=347 Volt

 

 

 

 

 

 

 

 

Total Harmonic Distortion < 10%

 

480V=480 Volt

 

 

 

 

No.

of Ballast

 

 

 

 

 

 

 

 

 

 

2, 3 or 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

 

DIM=Consult Factory(7)

 

L5830=T5 Lamp, 85CRI 3000K

 

 

 

 

 

 

 

 

 

 

L5835=T5 Lamp, 85CRI 3500K

 

 

 

 

 

 

 

 

 

 

L5841=T5 Lamp, 85CRI 4100K

 

 

 

 

 

 

 

 

 

 

L5850=T5 Lamp, 85CRI 5000K

 

 

 

 

 

 

 

 

 

 

GL=Single Element Fuse

 

 

 

 

 

 

 

 

 

 

GM=Double Element Fuse

 

 

 

 

 

 

 

 

 

 

Emergency=Emergency Installed(2)

 

 

 

 

 

 

Options

 

Packaging

MWS=Modular Wiring System

 

U=Unit Pack

MS=Aisle Coverage Motion

 

PAL=Palletized

Sensor(4)

 

Out of Carton

MSO=360˚ Coverage Motion

 

PALC=Palletized

Sensor(4)

 

In Carton

 

MP=Modular Power

Receptacle(1) (2)

PC3-=3' Power Cord & Plug (Specify Voltage)(2)

PC6-=6' Power Cord & Plug (Specify Voltage)(2)

TCBP=Top Connector Box Plate(5)

Accessories (order separately)

Mounting

AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks(8)

TCB=Top Connector Box RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop

MPC6=6' Modular Power Cord & Plug (Specify Voltage)

NOTES: (1)Requires use of MC or MPC cord accessories, specify voltage for plugs. (2)Voltage must be specified when ordered with plugs, motion or emergency ballasts. (3)EBT ballast systems suitable for operation in ambient environments up to 104°F (40°C). (4)Specify voltage on ballast. (5)For use with Top Connector Box options. See accessories. (6)2 lamp ballast configurations only in EHT-UNC versions. (7)Dimming ballast must be specified at time of order.

MC6=6' Modular Power Cord

MMS-CPD1200H=Aisle Motion Sensor, Box,

Modular Power Receptacle (120-277V)

MMS-CPD500H=360° Motion Sensor, Box,

Modular Power Receptacle (120/277V)

 

SHIPPING INFORMATION

 

 

 

 

 

 

 

 

 

 

Catalog No.

 

Wt.

 

 

 

3HBO-854T5-120V-UPL

27 lbs.

 

Specifications and Dimensions subject to change without notice.

 

ADF060953

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

07/07/2008 3:33:13 PM

Page 2
Image 2
Cooper Lighting P4S333 Candela, Effi c i e n t s of Utilization, Zonal Lumen Summary Luminance Data, Width, Series, Options