Cooper Lighting P5 M120 E5SR manual P5-M120-E5SRC, C a n d e l a s, Distribution L u m i n a n c e

Models: P5 M120 E5SR

1 2
Download 2 pages 21.31 Kb
Page 2
Image 2
P5-M120-E5SRC

Unit Number: P 5 - M 1 2 0 - E 5 S R _

P H O T O M E T R I C S

P5-M120-E5SRC

Test No. H36116

C a n d e l a s

Vertical

CD

Distribution L u m i n a n c e

Degree cd/m2

Cone of Light

Distance to

Initial Nadir

Beam

Lamp: 75A19/IF

Lumens: 885

Cutoff:

75°

Spacing:

1.0

Efficiency:

32.8%

Unit LPW:

3.8

Angle

 

90

0

85

0

75

3

65

18

55

39

45

68

35

99

25

129

15

156

5

174

0

176

85˚0

75˚774

65˚ 3065

55˚ 4817

45˚ 6914

Illuminated Plane

Footcandles

Diameter

4'6"

9

4'6"

5'6"

6

5'6"

6'6"

4

6'6"

8'0"

3

8'0"

10'0"

2

10'0"

12'0"

1

12'0"

Zonal Lumen Summary

 

 

Coefficient of Utilization

 

 

 

 

 

 

 

 

Zone

Lumens

%Lamp

%Luminaire

Ceiling Reflectance

 

 

80%

 

 

70%

 

50%

 

30%

0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-30

120

13.5

41.2

 

Wall Reflectance

70

50

30

10

50

10

50

10

50

10

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-40

182

20.5

62.5

 

Room Cavity Ratio

 

 

 

 

 

 

 

 

 

 

 

0-60

269

30.4

92.7

 

0

 

39

39

39

39

38

38

36

36

35

35

33

0-90

290

32.8

100.0

 

1

 

37

36

35

34

35

33

34

32

32

31

30

90-180

0

0.0

0.0

 

2

 

35

33

31

30

32

29

31

29

30

28

27

0-180

290

32.8

100.0

 

3

 

32

30

28

26

29

26

28

26

28

25

24

 

 

 

 

 

4

 

30

27

25

23

27

23

26

23

25

23

22

 

 

 

 

 

5

 

28

25

23

21

25

21

24

21

23

20

20

 

 

 

 

 

6

 

26

23

20

19

22

19

22

18

21

18

18

 

 

 

 

 

7

 

24

21

18

17

20

17

20

16

20

16

16

 

 

 

 

 

8

 

23

19

17

15

19

15

18

15

18

15

14

 

 

 

 

 

9

 

21

17

15

14

17

13

17

13

17

13

13

 

 

 

 

 

10

20

16

14

12

16

12

16

12

15

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes and Formulas:

Luminance: To convert cd/m2 to footlamberts, multiply by 0.2919

CU Notes/Formulas:

Cone of Light:

• maintained illuminance=lamp lumens x CU x light loss factors

 

 

room area

 

• Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.

 

 

 

 

 

 

 

• Footcandle values are initial. Apply appropriate light loss factors where necessary.

• total number of luminaires=total room area x maintained illuminance

See Iris catalog for further discussion.

 

 

lamp lumens x CU x light loss factors

 

 

 

 

 

 

 

• CU data based on 20% effective floor cavity reflectance.

 

 

 

Note: Specifications and Dimensions subject to change without notice.

 

 

 

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 ADI030813

Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049