Cooper Lighting E7T, P7 C a n d e l a s, Distribution L u m i n a n c e, Cone of Light, Candelas

Models: E7T M42T P7

1 2
Download 2 pages 46.17 Kb
Page 2
Image 2
C a n d e l a s

Unit Number: P 7 - M 4 2 T- E 7 T _

P 7 - M 3 2 T- E 7 T _

P H O T O M E T R I C S

P7-M42T-E7TC

Test No. H35091

C a n d e l a s

Vertical

CD

Distribution L u m i n a n c e

Degree cd/m2

Cone of Light

Distance to

Initial Nadir

Beam

Lamp:

42W PLT

Lumens:

3200

Cutoff:

50°

Spacing:

1.0

Efficiency:

44.8%

Unit LPW:

27.0

Angle

 

90

0

85

0

75

0

65

0

55

1

45

142

35

594

25

947

15

1313

5

1397

0

1279

85˚0

75˚0

65˚0

55˚76

45˚ 8768

Illuminated Plane

Footcandles

Diameter

4'6"

63

4'6"

5'6"

42

5'6"

6'6"

30

6'6"

8'0"

20

8'0"

10'0"

13

10'0"

12'0"

9

12'0"

Zonal Lumen Summary

 

 

Coefficient of Utilization

 

 

 

 

 

 

 

 

Zone

Lumens

%Lamp

%Luminaire

Ceiling Reflectance

 

 

80%

 

 

70%

 

50%

 

30%

0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-30

933

29.2

65.1

 

Wall Reflectance

70

50

30

10

50

10

50

10

50

10

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-40

1299

40.6

90.6

 

Room Cavity Ratio

 

 

 

 

 

 

 

 

 

 

 

0-60

1433

44.8

100.0

 

0

 

53

53

53

53

52

52

50

50

48

48

45

0-90

1433

44.8

100.0

 

1

 

50

48

47

45

47

44

45

43

43

42

40

90-180

0

0.0

0.0

 

2

 

47

45

43

41

44

40

42

39

41

39

37

0-180

1433

44.8

100.0

 

3

 

45

42

39

37

41

37

40

36

39

36

35

 

 

 

 

 

4

 

43

39

36

34

38

34

37

34

37

33

32

 

 

 

 

 

5

 

40

36

34

32

36

31

35

31

34

31

30]

 

 

 

 

 

6

 

38

34

31

29

34

29

33

29

32

29

28

 

 

 

 

 

7

 

36

32

29

27

32

27

31

27

31

27

26

 

 

 

 

 

8

 

34

30

27

25

30

25

29

25

29

25

24

 

 

 

 

 

9

 

33

28

25

24

28

23

27

23

27

23

23

 

 

 

 

 

10

31

26

24

22

26

22

26

22

26

22

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P7-M32T-E7TC

Test No. H35094

Lamp:

32W PLT

Lumens:

2400

Cutoff:

50°

Spacing:

0.9

Efficiency:

43.4%

Unit LPW:

28.9

Candelas

Vertical

CD

Angle

 

90

0

85

0

75

0

65

0

55

1

45

75

35

371

25

701

15

1083

5

1159

0

1083

Distribution

Luminance

Degree cd/m2

85˚0

75˚0

65˚0

55˚76

45˚ 4631

Cone of Light

Distance to

Initial Nadir

Beam

Illuminated Plane

Footcandles

Diameter

4'6"

54

4'0"

5'6"

36

5'0"

6'6"

26

6'0"

8'0"

17

7'6"

10'0"

11

9'0"

12'0"

8

11'0"

Zonal Lumen Summary

 

 

Coefficient of Utilization

 

 

 

 

 

 

 

 

Zone

Lumens

%Lamp

%Luminaire

Ceiling Reflectance

 

 

80%

 

 

70%

 

50%

 

30%

0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-30

733

30.5

70.4

 

Wall Reflectance

70

50

30

10

50

10

50

10

50

10

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-40

964

40.2

92.6

 

Room Cavity Ratio

 

 

 

 

 

 

 

 

 

 

 

0-60

1041

43.4

100.0

 

0

 

52

52

52

52

50

50

48

48

46

46

43

0-90

1041

43.4

100.0

 

1

 

48

46

45

43

45

43

44

41

42

40

38

90-180

0

0.0

0.0

 

2

 

46

43

41

39

42

39

41

38

40

37

36

0-180

1041

43.4

100.0

 

3

 

44

40

38

36

40

36

39

35

38

35

33

 

 

 

 

 

4

 

41

38

35

33

37

33

36

33

36

32

31

 

 

 

 

 

5

 

39

35

33

31

35

31

34

30

34

30

29

 

 

 

 

 

6

 

37

33

31

29

33

29

32

28

32

28

27

 

 

 

 

 

7

 

35

31

29

27

31

27

30

26

30

26

26

 

 

 

 

 

8

 

34

29

27

25

29

25

29

25

28

25

24

 

 

 

 

 

9

 

32

28

25

23

27

23

27

23

27

23

22

 

 

 

 

 

10

30

26

24

22

26

22

26

22

25

22

21

Notes and Formulas:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Luminance: To convert cd/m2 to footlamberts, multiply by 0.2919

Cone of Light:

Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.

Footcandle values are initial. Apply appropriate light loss factors where necessary. See page 64-65 of catalog.

CU Notes/Formulas:

maintained illuminance=lamp lumens x CU x light loss factors room area

total number of luminaires=total room area x maintained illuminance lamp lumens x CU x light loss factors

CU data based on 20% effective floor cavity reflectance.

Note: Specifications and Dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 ADI030703 Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049

Page 2
Image 2
Cooper Lighting E7T, P7, M42T manual C a n d e l a s, Distribution L u m i n a n c e, Cone of Light, Candelas, Luminance