Unit Number: P 7 - M 4 2 T- E 7 T _

P 7 - M 3 2 T- E 7 T _

P H O T O M E T R I C S

P7-M42T-E7TC

Test No. H35091

C a n d e l a s

Vertical

CD

Distribution L u m i n a n c e

Degree cd/m2

Cone of Light

Distance to

Initial Nadir

Beam

Lamp:

42W PLT

Lumens:

3200

Cutoff:

50°

Spacing:

1.0

Efficiency:

44.8%

Unit LPW:

27.0

Angle

 

90

0

85

0

75

0

65

0

55

1

45

142

35

594

25

947

15

1313

5

1397

0

1279

85˚0

75˚0

65˚0

55˚76

45˚ 8768

Illuminated Plane

Footcandles

Diameter

4'6"

63

4'6"

5'6"

42

5'6"

6'6"

30

6'6"

8'0"

20

8'0"

10'0"

13

10'0"

12'0"

9

12'0"

Zonal Lumen Summary

 

 

Coefficient of Utilization

 

 

 

 

 

 

 

 

Zone

Lumens

%Lamp

%Luminaire

Ceiling Reflectance

 

 

80%

 

 

70%

 

50%

 

30%

0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-30

933

29.2

65.1

 

Wall Reflectance

70

50

30

10

50

10

50

10

50

10

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-40

1299

40.6

90.6

 

Room Cavity Ratio

 

 

 

 

 

 

 

 

 

 

 

0-60

1433

44.8

100.0

 

0

 

53

53

53

53

52

52

50

50

48

48

45

0-90

1433

44.8

100.0

 

1

 

50

48

47

45

47

44

45

43

43

42

40

90-180

0

0.0

0.0

 

2

 

47

45

43

41

44

40

42

39

41

39

37

0-180

1433

44.8

100.0

 

3

 

45

42

39

37

41

37

40

36

39

36

35

 

 

 

 

 

4

 

43

39

36

34

38

34

37

34

37

33

32

 

 

 

 

 

5

 

40

36

34

32

36

31

35

31

34

31

30]

 

 

 

 

 

6

 

38

34

31

29

34

29

33

29

32

29

28

 

 

 

 

 

7

 

36

32

29

27

32

27

31

27

31

27

26

 

 

 

 

 

8

 

34

30

27

25

30

25

29

25

29

25

24

 

 

 

 

 

9

 

33

28

25

24

28

23

27

23

27

23

23

 

 

 

 

 

10

31

26

24

22

26

22

26

22

26

22

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P7-M32T-E7TC

Test No. H35094

Lamp:

32W PLT

Lumens:

2400

Cutoff:

50°

Spacing:

0.9

Efficiency:

43.4%

Unit LPW:

28.9

Candelas

Vertical

CD

Angle

 

90

0

85

0

75

0

65

0

55

1

45

75

35

371

25

701

15

1083

5

1159

0

1083

Distribution

Luminance

Degree cd/m2

85˚0

75˚0

65˚0

55˚76

45˚ 4631

Cone of Light

Distance to

Initial Nadir

Beam

Illuminated Plane

Footcandles

Diameter

4'6"

54

4'0"

5'6"

36

5'0"

6'6"

26

6'0"

8'0"

17

7'6"

10'0"

11

9'0"

12'0"

8

11'0"

Zonal Lumen Summary

 

 

Coefficient of Utilization

 

 

 

 

 

 

 

 

Zone

Lumens

%Lamp

%Luminaire

Ceiling Reflectance

 

 

80%

 

 

70%

 

50%

 

30%

0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-30

733

30.5

70.4

 

Wall Reflectance

70

50

30

10

50

10

50

10

50

10

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-40

964

40.2

92.6

 

Room Cavity Ratio

 

 

 

 

 

 

 

 

 

 

 

0-60

1041

43.4

100.0

 

0

 

52

52

52

52

50

50

48

48

46

46

43

0-90

1041

43.4

100.0

 

1

 

48

46

45

43

45

43

44

41

42

40

38

90-180

0

0.0

0.0

 

2

 

46

43

41

39

42

39

41

38

40

37

36

0-180

1041

43.4

100.0

 

3

 

44

40

38

36

40

36

39

35

38

35

33

 

 

 

 

 

4

 

41

38

35

33

37

33

36

33

36

32

31

 

 

 

 

 

5

 

39

35

33

31

35

31

34

30

34

30

29

 

 

 

 

 

6

 

37

33

31

29

33

29

32

28

32

28

27

 

 

 

 

 

7

 

35

31

29

27

31

27

30

26

30

26

26

 

 

 

 

 

8

 

34

29

27

25

29

25

29

25

28

25

24

 

 

 

 

 

9

 

32

28

25

23

27

23

27

23

27

23

22

 

 

 

 

 

10

30

26

24

22

26

22

26

22

25

22

21

Notes and Formulas:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Luminance: To convert cd/m2 to footlamberts, multiply by 0.2919

Cone of Light:

Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.

Footcandle values are initial. Apply appropriate light loss factors where necessary. See page 64-65 of catalog.

CU Notes/Formulas:

maintained illuminance=lamp lumens x CU x light loss factors room area

total number of luminaires=total room area x maintained illuminance lamp lumens x CU x light loss factors

CU data based on 20% effective floor cavity reflectance.

Note: Specifications and Dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 ADI030703 Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049

Page 2
Image 2
Cooper Lighting manual P7-M42T-E7TC, P7-M32T-E7TC

E7T, M42T, P7 specifications

Cooper Lighting is renowned for its advanced lighting solutions, and models like P7, M42T, and E7T showcase the brand’s commitment to innovation, energy efficiency, and performance. Each of these models brings unique features that cater to various applications in residential, commercial, and industrial settings.

The P7 model is distinguished by its sleek design and versatility. It offers a high lumen output, making it suitable for a wide range of applications, including outdoor lighting and area illumination. One of its standout features is the use of LED technology, which ensures not only energy efficiency but also a long lifespan. The P7 utilizes advanced thermal management systems that maintain optimal operating temperatures, thereby enhancing the reliability of the fixtures. The robust construction of the P7 ensures durability and resistance to harsh environmental conditions, making it a preferred choice for outdoor spaces.

Moving on to the M42T, this model is engineered for task lighting and high-efficiency applications. It features a compact design but does not compromise on performance, delivering bright, uniform light that is essential for workspaces. The M42T is equipped with Dimming Controls and smart technology options, allowing users to customize light levels based on their needs and preferences. Energy efficiency is further enhanced through integrated sensors that adjust lighting based on occupancy and ambient light levels. This characteristic significantly reduces energy consumption and lowers operational costs.

Lastly, the E7T model stands out with its innovative approach to lighting design. This model incorporates advanced optical technologies that optimize light distribution, ensuring minimal glare and maximum coverage. The E7T is designed with an emphasis on sustainability; it uses recyclable materials and has a low environmental impact. The installation process is made simple through its user-friendly design, which allows for quick mounting and adjustments.

In summary, Cooper Lighting’s P7, M42T, and E7T models exemplify cutting-edge lighting technology with energy-efficient features, robust construction, and intelligent design. Whether for outdoor illumination, task lighting, or specialized applications, these models provide reliable, high-quality lighting solutions that meet diverse user needs while promoting sustainability.