Architectural

COOPER LIGHTING - SURE-LITES®

D E S C R I P T I O ND I M E N S I O N S

EMERGENCY LIGHTS

RD SERIES

Tw o I n j e c t i o n M o l d e d T h e r m o p l a s t i c H e a d s

The RD Series is a recessed emergency lighting system designed for locations where aesthetics are of utmost importance. The housing is fully recessed in dry wall or grid ceiling installations. Designer pinchback heads rotate 358° and swivel 90° to 0°. Ideal for commercial and institutional environments where easy recessed installation and minimal maintenance are desired.

4 5/8"

8 1/4"

(118mm)

(210mm)

3 1/2" 6" (RD4 Only) (89mm) (152mm)

7" max.

(178mm)

5 1/8"

(130mm)

10 1/4" (260mm)

12 7/8" (327mm)

6 1/4" (159mm)

9 1/4" (235mm)

RLM SERIES

Tw o H i g h - I m p a c t

The RLM Series is a recessed system packaged in an attractive flame-resistant metal housing. It is the unit of choice for installations where a recessed product is desired and the size and cost of emergency lighting must be kept to a minimum without sacrificing dependability or light output.

81/4"

(210mm)

51/8"

(130mm)

10 1/4" (260mm)

12 7/8" (327mm)

4 5/8"

(118mm)

3 1/2" 6"(RLM4 Only)

(89mm) (152mm)

91/4"

(235mm)

6 1/4" (159mm)

9 1/4" (235mm)

T h e r m o p l a s t i c H e a d s

R e c e s s e d H o u s i n g

E M E R G E N C Y L I G H T

Dual-voltage input

120/277VAC, 60Hz

• 20 gauge die-formed steel

housing with white powder

coat finish

• Heads match housing

finish

• Knockout, conduit or cord

set

E L E C T R I C A L R A T I N G S

 

 

Rated Wattage to 87 1/2% of rated D.C. Voltage

 

Lamp Information

 

 

Model

Battery

DC Voltage

1 1/2 hours

2 hours

3 hours

4 hours

Type

Wattage

Number

RD1

SLC

6

18

15

10

8

Tungsten Halogen

6

29-12

RD3

SLC

6

27

24

18

14

Tungsten Halogen

12

29-66

RD4

SLC

12

54

-

-

-

Incandescent

9

029-86

RD6

SNC

6

15

12

8

6

Tungsten Halogen

6

29-12

RD7

SNC

6

24

18

12

10

Tungsten Halogen

12

29-66

RLM1

SLC

6

10.8

7.2

-

-

Incandescent

5.4

29-121

RLM2

SLC

6

18

15

10

8

Incandescent

9

29-84

RLM3

SLC

6

27

24

18

14

Incandescent

9

29-84

RLM4

SLC

12

54

-

-

-

Incandescent

9

029-86

RLM8

SNC

6

15

12

8

-

Incandescent

7.2

29-88

RLM9

SNC

6

24

18

12

10

Incandescent

7.2

29-88

SLC=Sealed Lead Calcium Battery

SNC=Sealed Nickel Cadmium Battery

O R D E R I N G I N F O R M AT I O N

S A M P L E N U M B E R : R D 1 V

• Supplied with hanger bars,

 

T-Bar clips

Single modular electrical

 

connector

Remote capability

Line-latching, Solid-State

 

voltage limited charger,

 

Solid-State switching,

Model Number RD1

RD3

RD4

RD6

RD7

RLM1

RLM2

RLM3

RLM4

RLM8

RLM9

Options

(Add as suffix) A=Ammeter(2) SD=Self-Diagnostics TDM=Time Delay Monitor V=Voltmeter(2)

Alternate Lamps(1)

Other Options(1)

Accessories

(Order separately) WG2 =Wire Guard WG7 =Wire Guard VS=Choose polycarbonate

vandal shield desired from accessories sheet

606

low- voltage disconnect,

brownout circuit,

overload/short-circuit

protection, test

switch/power indicator

light

• UL 924 Listed, Life Safety

NFPA 101, NEC/OSHA,

most state and local codes

COOPER LIGHTING

E n e r g y D a t a

 

Input Current (Max.):

Model No.

120V

277V

RD1, RD3

.12A

.05A

RD4, RLM4

.30A

.13A

RD6

.06A

.03A

RD7

.07A

.04A

RLM1, RLM2, RLM3

.12A

.05A

RLM8

.06A

.03A

RLM9

.07A

.04A

(1)Consult your Cooper Lighting Representative. (2) Provision for one meter only.

Page 1
Image 1
Cooper Lighting RLM Series dimensions RD Series