S Q U A R E TA P E R E D S T E E L P O L E S
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : S T S 7 A 3 0 S F M 1 X G
|
|
|
|
|
|
| Mounting |
|
| Fixture | No. & |
|
| Accessories | ||
|
|
| Shaft 3 |
| Wall |
| Height | Base |
|
| Mounting | Location |
| Arm | (Ground | |
Square | Straight | Steel | Size |
| Thickness |
| (ft.) | Type | Finish | & Type | of Arms |
| Lengths | Lug) | ||
S | T | S | 7 |
| A |
| 30 | S | F |
| M |
| 1 |
| X | G |
|
|
|
| Bolt |
|
|
| Anchor |
|
|
|
|
|
|
|
|
| Catalog 1, 2 |
| Base | Circle | Bolt | Shaft |
| Bolt | Net. | EPA (Sq. Ft.) 4 |
| EPA (Sq. Ft.) 4 |
| Max. Fixture | ||
Mtg. | Wall | Square | Dia. | Proj. | Size |
| Dia. &. | Wt. |
|
|
| |||||
Height | Number | Thickness | (In.) | (In.) | (In.) | (In.) |
| Length (In.) | (Lbs.) | At Pole Top |
| 2' Above Pole Top | Bracket (Lbs.) |
| ||
MH |
|
| S | BC | BP | B |
| AB |
| 80 | 90 | 100 | 80 | 90 | 100 |
|
20 | STS6A20SF | .120 |
|
|
|
|
| Consult your Cooper Lighting Representative |
|
|
|
| ||||
25 | STS6A25SF | .120 |
|
|
|
|
| Consult your Cooper Lighting Representative |
|
|
|
| ||||
30 | STS7A30SF | .120 |
|
|
|
|
| Consult your Cooper Lighting Representative |
|
|
|
| ||||
30 | STS7D30SF | .180 |
|
|
|
|
| Consult your Cooper Lighting Representative |
|
|
|
| ||||
35 | STS8A35SF | .120 |
|
|
|
|
| Consult your Cooper Lighting Representative |
|
|
|
| ||||
39 | STS8A39SF | .120 |
|
|
|
|
| Consult your Cooper Lighting Representative |
|
|
|
|
NOTES: 1 Catalog number includes pole with anchor bolts with double nuts (BEFORE INSTALLING ANCHOR BOLTS MAKE SURE PROPER ANCHOR BOLT TEMPLATE IS OBTAINED FROM COOPER LIGHTING HEADQUARTERS). 2 Tenon size or machining for rectangular arms must be specified. Hand hole is located 180° from single arm.
3 Shaft size, base plate, anchor bolts and projections may vary
4 EPAs based on shaft properties with wind normal to flat. EPAs calculated using base wind velocity as indicated plus 30% gust factor.
D R I L L I N G PAT T E R N
Type “M” [RCL, Landau, Galleria and Vision] | Type “E” [Concourse III] | Type “Z” [Credenza and Cirrus] |
2 5/16'' |
| 2 13/16'' |
| 3/4'' dia. |
|
2 7/16'' | hole | 7/8'' |
4 7/8'' |
| 3 7/8'' |
3/4'' dia. | 4" [102mm] | |
|
| |
hole |
|
|
2 7/16" [62mm] |
| |
|
| |
|
|
|
| 4 7/8" [124mm] | |
|
|
|
(2)5/8'' dia. holes
(2) 3/8" | 9/16" [14mm] |
dia. holes | dia. hole (3) |
M A C H I N I N G F O R R E C TA N G U L A R A R M S [ A d d a s s u f f i x ]
Designation | Designation | Designation | Quantity | |
Letter & Number | Letter & Number | Letter & Number | & Location | |
M1 | E1 | Z1 | Single | |
M2 | E2 | Z2 | 2 | @ 180° |
M3 | E3 | Z3 | 3 | @ 120° |
M4 | E4 | Z4 | 4 | @ 90° |
M5 | E5 | Z5 | 2 | @ 90° |
NOTES: Refer to Fixture Drilling Options on page 160.
M O U N T I N G O P T I O N S [ A d d a s s u f f i x ] |
|
|
| A C C E S S O R I E S | ||||||||
Fixed Tenon |
|
| Designation | O.D. | Length | A=1/2" tapped hub 1 | ||||||
|
| O.D. |
|
|
|
|
| Number | (In.) | (In.) | B=3/4" tapped hub 1 | |
|
|
|
|
|
|
| 1 | 2 3/8 | 3 1/2 |
| C=Convenience outlet 2 | |
|
|
|
|
|
|
|
| |||||
|
|
|
|
| 2 | 2 3/8 | 4 |
| G=Grounding lug (max. wire #8 AWG) | |||
|
|
|
|
|
| |||||||
|
|
|
|
|
|
| 3 | 3 1/2 | 5 |
| H=Additional hand hole and cover— | |
|
|
|
|
|
|
| 9 | 3 | 4 |
| 12" below pole | |
|
|
|
|
|
|
| ||||||
|
|
|
|
| LENGTH |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
NOTES: 1 Location is 3' above
2 Outlet is located 4' above base and on same side of pole as hand hole, unless specified otherwise. Receptacle not included, provision only.
NOTE: Specifications and dimensions subject to change without notice.
C o o p e r L i g h t i n g | S T R E E T W O R K S O u t d o o r L i g h t i n g S o l u t i o n s 175 |