PHOTOMETRICS

 

 

 

 

 

 

 

 

 

 

VT2

 

VT2-254DR-UNV-

Candlepower

 

 

 

VT2-232DR-UNV-

Candlepower

 

 

 

EB81-WL-M4-U

 

 

 

 

 

EB81-WL-M4-U

 

 

 

 

 

Electronic Ballast

Angle

Along II

45°

Across ?

 

Electronic Ballast

Angle

Along II

45°

Across ?

?

(2) F54/T5/835 Lamps

0

1615

1615

1615

 

(2)T8 Lamps

0

1036

1036

1036

5

1613

1632

1648

?

5

1036

1059

1077

 

4460 Lumens each

2850 Lumens each

 

10

1592

1673

1723

 

10

1023

1114

1175

 

Spacing criterion:

15

1556

1704

1781

 

Spacing criterion:

15

1000

1175

1275

 

(II) 1.2 x mounting

20

1504

1717

1820

 

(II) 1.3 x mounting

20

968

1227

1344

 

25

1438

1712

1839

 

25

926

1255

1352

 

height, (? ) 1.6 x

 

height, (? ) 1.6 x

 

30

1357

1683

1815

 

30

876

1245

1284

 

mounting height

 

mounting height

 

35

1262

1625

1743

35

817

1184

1182

Efficiency 74.3%

40

1154

1532

1635

 

Efficiency 81.7%

40

750

1080

1070

45

1033

1412

1499

 

45

674

961

946

 

Test Report:

 

Test Report:

 

50

902

1263

1355

 

50

591

834

833

 

127P111

55

762

1101

1180

 

127P113

55

501

706

780

 

LER = FI57

60

621

944

994

 

LER = FI71

60

408

597

785

 

65

485

775

968

 

65

317

533

816

 

Yearly Cost of 1000

 

Yearly Cost of 1000

 

70

362

667

1051

 

70

233

520

755

 

lumens, 3000 hrs at

75

253

677

992

 

lumens, 3000 hrs at

75

160

489

624

 

.08 KWH = $4.24

80

158

612

827

 

.08 KWH = $3.39

80

97

396

518

 

85

74

455

647

 

85

45

302

434

 

 

 

 

 

 

90

26

297

463

 

 

90

16

224

353

C o effi ci e n t s of Utilization

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

87

87

87

87

85

85

85

85

80

80

80

76

76

76

72

72

72

70

 

1

 

78

73

70

66

75

71

68

65

67

64

62

64

61

59

60

59

57

55

 

2

 

70

63

57

52

68

61

56

51

58

53

50

55

51

48

52

49

46

44

 

3

 

64

55

48

43

61

53

47

42

51

45

41

48

43

40

45

42

39

37

 

4

 

58

48

41

36

56

47

40

35

45

39

34

42

38

34

40

36

33

31

 

5

 

53

43

36

31

51

42

35

30

40

34

30

38

33

29

36

32

28

26

 

6

 

49

39

32

27

47

38

31

26

36

30

26

34

29

25

33

28

25

23

 

7

 

45

35

28

23

44

34

28

23

32

27

23

31

26

22

30

25

22

20

 

8

 

42

32

25

21

41

31

25

20

30

24

20

28

23

20

27

23

19

18

 

9

 

39

29

23

18

38

28

22

18

27

22

18

26

21

18

25

21

17

16

 

10

 

37

27

21

17

36

26

20

16

25

20

16

24

19

16

23

19

16

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coeffi cients of Utilization

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

96

96

96

96

93

93

93

93

87

87

87

82

82

82

78

78

78

76

 

1

 

86

81

77

73

83

78

74

71

74

70

68

69

67

64

65

63

61

59

 

2

 

77

69

63

58

74

67

61

57

63

58

54

60

56

52

56

53

50

48

 

3

 

70

60

53

47

67

59

52

46

55

49

45

52

47

43

49

45

42

40

 

4

 

64

53

45

40

61

52

44

39

49

43

38

46

41

37

44

39

35

33

 

5

 

58

47

39

34

56

46

39

33

44

37

32

41

36

31

39

34

31

29

 

6

 

54

42

35

29

52

41

34

29

39

33

28

37

32

27

35

30

27

25

 

7

 

50

38

31

26

48

37

30

25

35

29

25

34

28

24

32

27

24

22

 

8

 

46

35

28

23

45

34

27

22

32

26

22

31

25

21

29

25

21

19

 

9

 

43

32

25

20

42

31

25

20

30

24

20

28

23

19

27

22

19

17

 

10

 

40

29

23

18

39

29

22

18

27

22

18

26

21

17

25

20

17

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zonal Lumen Summary

Luminance Data

 

 

 

Zonal Lumen Summary

Luminance Data

 

 

 

 

 

 

 

 

Average

Average

Average

 

 

 

 

 

 

 

Average

Average

Average

Zone

Lumens

%Lamp

%Fixture

 

Angle

0-Deg

45-Deg

90-Deg

 

Zone

Lumens

%Lamp

%Fixture

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

 

in Deg

cd/sm

cd/sm

cd/sm

0-30

1411

15.8

21.3

 

 

 

 

 

 

0-30

985

17.3

21.1

 

 

 

 

 

45

7779

10632

11288

45

4874

6095

5343

0-40

2397

26.9

36.2

 

 

 

 

 

 

0-40

1675

29.4

36.0

 

 

 

 

 

55

7074

10221

10954

55

4392

5171

4906

0-60

4380

49.1

66.2

 

 

 

 

 

 

0-60

2999

52.6

64.4

 

 

 

 

 

65

6110

9764

12196

65

3669

4791

5995

0-90

6268

70.3

94.8

 

 

 

 

 

 

0-90

4316

75.7

92.7

 

 

 

 

 

75

5205

13928

20408

75

2853

5921

5721

0-180

6614

74.2

100.0

 

 

 

 

 

 

0-180

4658

81.7

100.0

 

 

 

 

 

85

4251

27797

39527

85

1868

5874

5512

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORDERING INFORMATION

S A M P L E NUMBER: 8TVT2 - 254DR - UNV- EB82 - M4 - U

Width

Blank=4' Length

8T=8' Length

Series

VT2=Vapor-Tite

Number of Lamps(3) 1=1 lamp (T5 or T8) 2=2 lamps (T5 or T8) 3=3 lamps (T8 only)

(Lamps not included)

Lamp Type

32=32W T8 Lamp (4' Long)

54T5=54W T5HO Lamp (4' Long)

Lens

Voltage (1)

120V=120 Volt

277V=277 Volt

347V=347 Volt

480V=480 Volt

UNV=Universal

Voltage 120/277V

UNC=Universal

Voltage 347/480V

(T5 Linear Only)

Fusing

GL=Single Element Fuse GM=Double Element Fuse

Emergency=EM Installed, see EM options table(3) (4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WL=Wet

 

 

 

 

 

 

 

 

Location

BallastType (1)

 

T8 Systems

 

 

 

 

 

Label

 

 

 

 

 

 

 

EB8 =T8 Electronic Instant Start.(4)

 

 

 

 

 

Total Harmonic Distortion < 20%

 

 

 

 

of Ballast

 

 

 

No.

 

 

 

1 or 2

 

 

 

 

 

 

 

EB8 /PLUS=T8 Electronic Instant Start.

 

 

 

 

 

 

High Ballast Factor >1.13.Total

 

No. of

Harmonic Distortion < 20%

 

Ballast

 

 

 

 

 

 

 

 

 

1 or 2

 

 

 

 

 

 

 

ER8 =T8 Electronic Program Rapid Start.

 

 

 

Total Harmonic Distortion < 10%

 

 

 

No.

of Ballast

 

 

 

1 or 2

 

 

 

 

 

 

 

ER8 /PLUS=T8 Electronic Program Start.

 

 

 

 

High Ballast Factor >1.13.Total

 

No. of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

Packaging

RIF1=Radio

U=Unit Pack

Interference Suppressor

PALC=Job

TH=(2) Top Watertite Hubs

Pack in Carton

TEH=(2) Top & (2) End Watertite Hubs (all Watertite Hubs have 1/2" Conduit Entry)

TILW=Tandem In-Line Wiring

Option (Consult TILW Option Catalog Page) PI/CPI=Plug-In Option

DD=Deep Diffuser (4' Length)

(Available for 4' Fixture Length)To Complement Deep Diffuser Depth of 8' Fixture

M4=Specular Reflector

SSL=Stainless Steel Latches

ACCESSORIES

DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard) DR-100%=100% High Impact Additive

LEX=High Impact Clear Polycarbonate LEXAN Lens/Low Brightness Pattern

NOTES: (1)Ballast type used only if ballast & voltage is chosen (2)Not available when specify- ing emergencies, voltage must be specific. (3) T5HO is only available in 1 or 2-lamp versions only. (4)Emergency option in 3 lamp version must use remote mount test switch.

 

Ballast

Harmonic Distortion < 10%

 

 

 

1 or 2

 

EB8 /L=T8 Electronic Instant Start w/0.80

 

 

 

 

 

Ballast Factor.

 

 

of Ballast

 

No.

 

1 or 2

 

T5 Systems

EBT =T5HO Electronic Program Start.

 

 

of Ballast

 

No.

 

1 or 2

 

Accessories (order separately) VT2-Chain/Set-U=Chain Hanging Set

Includes 6 ft. of chain, 4 large S-Hooks and 4 small S-Hooks

Order One (1) Kit for each

2' or 4' Fixture

Two (2) Kits Recommended For 8' Fixture

VT2-SS-MBK=Stainless

Steel Mounting Bracket

SHIPPING DATA

Catalog No.

Wt.

VT2-132DR-WL

35 lbs.

 

VT2-232DR-WL

35 lbs.

 

 

 

 

Specifications and Dimensions subject to change without notice.

ADF071394

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

09/29/2008 10:06:07 AM

Page 2
Image 2
Cooper Lighting VT2 specifications Ordering Information, Accessories, Shipping Data

VT2 specifications

Cooper Lighting's VT2, a versatile and advanced lighting solution, has garnered attention for its exceptional performance and innovative technologies. Designed to meet the demands of various applications, the VT2 series stands out for its energy efficiency, durability, and adaptability.

One of the most notable features of the VT2 is its LED technology, which provides a significant reduction in energy consumption compared to traditional lighting solutions. With an impressive lumen output per watt, the VT2 ensures bright illumination while minimizing operational costs, making it an eco-friendly choice for both residential and commercial settings.

The VT2 is praised for its sleek and modern design, which seamlessly blends with a variety of architectural styles. The fixture is available in multiple configurations, making it adaptable for different environments, whether it be offices, retail spaces, or outdoor areas. Its robust construction ensures longevity and resistance to harsh weather conditions, further extending its applicability.

Equipped with advanced optical systems, the VT2 offers uniform light distribution, crucial for reducing shadows and enhancing visibility. This feature is particularly beneficial in workspaces where accurate lighting is essential for productivity and safety. Additionally, the integrated thermal management system helps maintain optimal performance by dissipating heat, thereby prolonging the lifespan of the LEDs.

Another critical aspect of the VT2 series is the customizable controls available. From dimming capabilities to smart lighting integration, users can tailor the lighting experience to meet their specific needs. This flexibility is increasingly important in today's energy-conscious landscape, where the ability to adjust lighting based on occupancy and time of day can result in further energy savings.

The VT2 is also compatible with various mounting options, making installation straightforward and adaptable for different ceiling types. This versatility allows for both new constructions and retrofitting projects, facilitating upgrades in existing facilities without significant alterations.

In summary, Cooper Lighting's VT2 represents the intersection of cutting-edge technology and practical functionality. With its energy-efficient LED design, customizable features, robust construction, and modern aesthetics, the VT2 is poised to revolutionize the lighting experience for diverse applications. As the demand for sustainable and efficient lighting solutions continues to rise, the VT2 stands out as a leading choice for those looking to enhance their spaces while minimizing their environmental impact. With Cooper Lighting's commitment to innovation, the VT2 is a testament to their vision of smarter lighting for a brighter future.