Photometrics
EB81-WL-U
(1) Electronic Ballasts
(2) 32W T8 lamps
2850 lumens
Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height
Efficiency 77.4%
Test Report:
LTL10864.IES
LER =72
Yearly Cost of 1000 lumens, 3000 hrs at
.08 KWH = $3.34
C a n d e l a
Angle | Along II | 45° | Across ⊥ |
0 | 1103 | 1103 | 1103 |
5 | 1097 | 1108 | 1107 |
10 | 1083 | 1107 | 1106 |
15 | 1059 | 1091 | 1127 |
20 | 1025 | 1089 | 1113 |
25 | 983 | 1058 | 1098 |
30 | 932 | 1035 | 1088 |
35 | 870 | 991 | 1052 |
40 | 801 | 952 | 1024 |
45 | 725 | 892 | 971 |
50 | 640 | 831 | 920 |
55 | 548 | 753 | 878 |
60 | 451 | 683 | 814 |
65 | 352 | 611 | 771 |
70 | 251 | 550 | 698 |
75 | 155 | 471 | 592 |
80 | 77 | 367 | 513 |
85 | 28 | 290 | 427 |
90 | 6 | 217 | 342 |
(1)Electronic Ballasts
(2)54W T5 lamps
4400 lumens
Spacing criterion:
(II)1.2 x mounting height, (⊥) 1.5 x mounting height
Efficiency 69.7%
Test Report:
LTL10777.IES
LER =59
Yearly Cost of 1000 lumens, 3000 hrs at
.08 KWH = $4.05
C a n d e l a
Angle | Along II | 45° | Across ⊥ |
0 | 1546 | 1546 | 1546 |
5 | 1540 | 1525 | 1533 |
10 | 1519 | 1548 | 1525 |
15 | 1483 | 1514 | 1546 |
20 | 1436 | 1509 | 1566 |
25 | 1375 | 1487 | 1530 |
30 | 1300 | 1446 | 1509 |
35 | 1215 | 1396 | 1502 |
40 | 1118 | 1315 | 1425 |
45 | 1012 | 1267 | 1384 |
50 | 896 | 1174 | 1308 |
55 | 770 | 1081 | 1179 |
60 | 634 | 954 | 1107 |
65 | 496 | 827 | 1101 |
70 | 352 | 771 | 1044 |
75 | 219 | 704 | 936 |
80 | 113 | 578 | 807 |
85 | 47 | 432 | 614 |
90 | 13 | 285 | 431 |
C o e f f i c i e n t s o f U t i l i z a t i o n
|
|
| Effective floor cavity reflectance | 20% |
|
|
|
|
|
|
|
|
|
| |||||||
| rc |
|
| 80% |
|
| 70% |
|
| 50% |
|
| 30% |
|
| 10% |
| 0% |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| rw |
| 70 | 50 | 30 | 10 | 70 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 |
|
RCR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
0 |
| 91 | 91 | 91 | 91 | 89 | 89 | 89 | 89 | 84 | 84 | 84 | 79 | 79 | 79 | 75 | 75 | 75 | 73 |
| |
1 |
| 82 | 78 | 74 | 70 | 79 | 75 | 72 | 69 | 71 | 68 | 66 | 67 | 65 | 63 | 64 | 62 | 60 | 58 |
| |
2 |
| 74 | 67 | 61 | 56 | 71 | 65 | 60 | 55 | 61 | 57 | 53 | 58 | 54 | 51 | 55 | 52 | 49 | 47 |
| |
3 |
| 67 | 58 | 52 | 46 | 65 | 57 | 51 | 46 | 54 | 49 | 44 | 51 | 47 | 43 | 49 | 45 | 42 | 40 |
| |
4 |
| 61 | 51 | 44 | 39 | 59 | 50 | 43 | 38 | 48 | 42 | 37 | 45 | 40 | 36 | 43 | 39 | 35 | 33 |
| |
5 |
| 56 | 45 | 38 | 32 | 54 | 44 | 37 | 32 | 42 | 36 | 31 | 40 | 34 | 30 | 38 | 33 | 30 | 28 |
| |
6 |
| 51 | 40 | 33 | 28 | 49 | 39 | 32 | 27 | 37 | 31 | 27 | 36 | 30 | 26 | 34 | 29 | 26 | 24 |
| |
7 |
| 47 | 36 | 29 | 24 | 45 | 35 | 28 | 23 | 33 | 27 | 23 | 32 | 27 | 23 | 30 | 26 | 22 | 20 |
| |
8 |
| 43 | 32 | 25 | 20 | 42 | 31 | 25 | 20 | 30 | 24 | 20 | 29 | 23 | 19 | 27 | 23 | 19 | 17 |
| |
9 |
| 40 | 29 | 22 | 17 | 38 | 28 | 22 | 17 | 27 | 21 | 17 | 26 | 20 | 17 | 25 | 20 | 16 | 15 |
| |
10 |
| 37 | 26 | 20 | 15 | 36 | 26 | 19 | 15 | 24 | 19 | 15 | 23 | 18 | 15 | 22 | 18 | 14 | 13 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Z o n a l L u m e n S u m m a r y | L u m i n a n c e D a t a |
|
| |||||
|
|
|
|
|
| Average | Average | Average |
Zone | Lumens | %Lamp | %Fixture | Angle | ||||
in Deg | cd/sm | cd/sm | cd/sm | |||||
|
|
|
|
|
|
|
|
|
899 | 15.8 | 20.4 | 45 | 5519 | 7213 | 7212 | ||
|
|
|
|
|
|
|
|
|
1512 | 26.5 | 34.3 | 55 | 5083 | 6756 | 7098 | ||
|
|
|
|
|
|
|
|
|
2847 | 49.9 | 64.5 | 65 | 4347 | 6377 | 7074 | ||
|
|
|
|
|
|
|
|
|
4169 | 73.1 | 94.5 | 75 | 3001 | 6097 | 6510 | ||
|
|
|
|
|
|
|
|
|
4413 | 77.4 | 100.0 | 85 | 1349 | 5151 | 6092 | ||
|
|
|
|
|
|
|
|
|
C o e f f i c i e n t s o f U t i l i z a t i o n
|
|
| Effective floor cavity reflectance | 20% |
|
|
|
|
|
|
|
|
| |||||||
| rc |
|
| 80% |
|
| 70% |
|
| 50% |
|
| 30% |
|
| 10% |
| 0% | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| rw |
| 70 | 50 | 30 | 10 | 70 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 |
RCR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
0 |
| 82 | 82 | 82 | 82 | 80 | 80 | 80 | 80 | 76 | 76 | 76 | 72 | 72 | 72 | 69 | 69 | 69 | 67 | |
1 |
| 74 | 70 | 66 | 63 | 72 | 68 | 65 | 62 | 65 | 62 | 59 | 61 | 59 | 57 | 58 | 57 | 55 | 53 | |
2 |
| 66 | 60 | 55 | 50 | 64 | 58 | 54 | 49 | 55 | 51 | 48 | 53 | 49 | 46 | 50 | 47 | 45 | 43 | |
3 |
| 60 | 52 | 46 | 41 | 58 | 51 | 45 | 41 | 49 | 44 | 40 | 46 | 42 | 39 | 44 | 41 | 38 | 36 | |
4 |
| 55 | 46 | 40 | 35 | 53 | 45 | 39 | 34 | 43 | 38 | 33 | 41 | 36 | 33 | 39 | 35 | 32 | 30 | |
5 |
| 50 | 40 | 34 | 29 | 48 | 40 | 33 | 29 | 38 | 32 | 28 | 36 | 31 | 27 | 34 | 30 | 27 | 25 | |
6 |
| 46 | 36 | 29 | 25 | 44 | 35 | 29 | 24 | 34 | 28 | 24 | 32 | 27 | 24 | 31 | 26 | 23 | 22 | |
7 |
| 42 | 32 | 26 | 21 | 41 | 32 | 25 | 21 | 30 | 25 | 21 | 29 | 24 | 20 | 28 | 23 | 20 | 18 | |
8 |
| 39 | 29 | 23 | 18 | 38 | 28 | 22 | 18 | 27 | 22 | 18 | 26 | 21 | 17 | 25 | 20 | 17 | 16 | |
9 |
| 36 | 26 | 20 | 16 | 35 | 25 | 19 | 15 | 24 | 19 | 15 | 23 | 18 | 15 | 22 | 18 | 15 | 13 | |
10 |
| 33 | 23 | 18 | 14 | 32 | 23 | 17 | 14 | 22 | 17 | 13 | 21 | 17 | 13 | 20 | 16 | 13 | 12 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Z o n a l L u m e n S u m m a r y | L u m i n a n c e D a t a |
|
| |||||
|
|
|
|
|
| Average | Average | Average |
Zone | Lumens | %Lamp | %Fixture | Angle | ||||
in Deg | cd/sm | cd/sm | cd/sm | |||||
|
|
|
|
|
|
|
|
|
1253 | 14.2 | 20.4 | 45 | 7704 | 10245 | 10279 | ||
|
|
|
|
|
|
|
|
|
2112 | 24.0 | 34.4 | 55 | 7142 | 9700 | 9531 | ||
|
|
|
|
|
|
|
|
|
3985 | 45.3 | 64.9 | 65 | 6126 | 8631 | 10102 | ||
|
|
|
|
|
|
|
|
|
5908 | 67.1 | 96.3 | 75 | 4240 | 9114 | 10293 | ||
|
|
|
|
|
|
|
|
|
6137 | 69.7 | 100.0 | 85 | 2265 | 7674 | 8760 | ||
|
|
|
|
|
|
|
|
|
Ordering Information S A M P L E N U M B E R : V T 3 - 2 3 2 D R - U N V- E B 8 1 - W L- U
VT3
Tandem
Blank= 4' Length 8T=8' Length
Series
VT3=Vaportite
Number of Lamps3 1, 2 or 3 Lamps
(Not included)
Wattage (Length)
32=32W T8 (48")
28T5=28W T5 (48") 54T5=54W T5HO (48")5
Voltage 1
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal Voltage 120/277 2 UNC=Universal Voltage 347/480
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency Installed
Ballast Type1
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast 1 or 2
EB8 /PLUS= | T8 Electronic Instant Start. | ||||
|
|
|
|
| High Ballast Factor >1.13. |
| No. of Ballast | Total Harmonic Distortion < 20% | |||
| 1 or 2 |
|
ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%
No. of Ballast 1 or 2
EBT =T5 Linear Electronic Program Rapid Start.4 Total Harmonic Distortion < 10%
WL=Wet Label
Lens
DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard)
No. of Ballast 1 or 2
EHT =T5 Linear Electronic Start High Ambient.5
Total Harmonic Distortion < 10%
No. of Ballast 1 or 2
NOTES:
1 Products also available in
2Not available when specifying emergencies, voltage must be specific.
3
4 EBT ballast option applies to 28W T5 only.
5 54W T5HO must use EHT ballast option. 8 ft. 54W T5HO must use (2) EHT ballasts.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.