D I M E N S I O N S
7"
[178mm]
28" [724mm] 17" [432mm]
6" [152mm
10" [254mm]
S T R U C T U R A L M O U N T
157/8"
[404mm]
D E S C R I P T I O N
The classic lines and sophisticated construction of the Vision Site luminaire makes it an ideal complement to site design. The combination of smooth contours and sharp rear reveals allow the fixture to change character from different viewing angles while providing excellent
INVUETM
VXM VISION SITE MEDIUM
AREA ROADWAY
33 7/8" [860mm] | E P A - E f f e c t i v e P r o j e c t e d A r e a : S i n g l e 1 . 6 / S i n g l e S t r u c t u r a l 1 . 8 2 |
|
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : V X M - 4 0 0 - M H - M T - 3 S - B K - P R C P S - L
8 5 - 4 0 0 W M e t a l H a l i d e P u l s e S t a r t M e t a l H a l i d e
Product
Family 1
VXM=Vision
Site
Medium
Lamp
Wattage
HID 2
150=150W
175=175W
250=250W
320=320W 3
350=350W 3
400=400W 4
Compact Fluorescent 114=(2) 57W 5 140=(2) 70W 5
Electrodeless
Fluorescent 85=85W 6
Lamp Type
MH=Metal
Halide
MP=Pulse Start
Metal Halide
HPS=High
Pressure
Sodium
CF=Compact
Fluorescent 7
QL=Electrodeless
Fluorescent
Voltage 8
120=120V
208=208V
240=240V
277=277V
347=347V
480=480V
Electronic Ballast
Optical System
2S=Type II
3S=Type III
4S=Type IV
5S=Type V SL=Spill Light
Eliminator 2F=Design 20
Formed 3F=Design 30 Formed 4F=Design 40 Formed 5F=Design 50 Formed
Colors 12 |
|
|
|
|
|
| |
Options & | |||
(add as suffix/ | Accessories | ||
must specify) | (See Below) | ||
BK=Black |
|
|
|
AP=Grey |
|
|
|
BZ=Bronze |
|
|
|
WH=White
DP=Dark Platinum
GM=Graphite Metallic
H i g h P r e s s u r e S o d i u m C o m p a c t F l u o r e s c e n t E l e c t r o d e l e s s F l u o r e s c e n t
A R C H I T E C T U R A L
A R E A L U M I N A I R E
Structural Options 13 |
|
| Options 13 | Accessories 20 | ||||||||
| Pole Mount |
|
| F=Single Fuse (120, 277 or 347V) |
|
| ||||||
PRCPS=Strut Rod and Clevis Set for |
|
| Specify Voltage | |||||||||
|
|
| Square Poles (Painted to match | FF=Double Fuse | ||||||||
|
|
| fixture) 14 |
|
| (208, 240 or 480V) | ||||||
PRCSS=Stainless Steel Strut Rod and |
|
| Specify Voltage | |||||||||
|
|
| Clevis Set for Square Poles |
|
| Q=Quartz Restrike 17 | ||||||
|
|
| (Clevis’ painted to match fixture) 14 | EM=Quartz Restrike with Time | ||||||||
PRCPR=Strut Rod and Clevis Set for Round | Delay (Also Strikes at Cold | |||||||||||
|
|
| Poles (Painted to match fixture) 15 | Start) 17 | ||||||||
PRCSR=Stainless Steel Strut Rod and |
|
| EM/SC=Quartz Emergency | |||||||||
|
|
| Clevis Set for Round Poles |
|
| Separate Circuit 17 | ||||||
|
|
| (Clevis’ painted to match fixture) 15 | R=NEMA Twistlock Photocell | ||||||||
Wall Mount |
|
| Receptacle | |||||||||
WRCP=Strut Rod and Clevis |
|
| DS=Dual Fluorescent Switching | |||||||||
|
|
| (Painted to match fixture) 16 |
|
| Control 18 | ||||||
WRCS=Stainless Steel Strut Rod and |
|
| HS=House Side Shield 19 | |||||||||
|
|
| Clevis Set (Clevis’ painted to match | VS=Polycarbonate Vandal Shield | ||||||||
|
|
| fixture) 16 |
|
| T=Terminal Block | ||||||
|
|
|
|
|
| L=Lamp Included | ||||||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| WATTAGE TABLE | VXM |
|
|
|
|
| |||
|
|
|
|
|
|
|
| |||||
|
|
| Metal Halide | 175, 250, 400W |
| |||||||
|
|
| ||||||||||
|
|
| Pulse Start Metal Halide | 250, 320, 350, 400W |
| |||||||
|
|
|
|
|
High Pressure Sodium | 150, 250, 400W |
|
|
Compact Fluorescent | (2) 57, (2) 70W | IP54 Rated | 3G Vibration Tested |
Electrodeless Fluorescent | 85W |
| 40°C Ambient |
NOTE: 1 Arm not included. See accessories. 2 All HID lamps are
14 Structural options do not include arm assembly (see accessories). Compatible with 10" MA1051 arm only. 15 Structural options do not include arm assembly (see accessories). Compatible with 10" MA1053 arm only. 16 Wall mount structural options do not include arm assembly (See Accessories). Compatible with 10" MA1231 arm only. 17 Quartz options not available with SL optic. 18 Dual switching requires dual 57W or dual 70W Compact Fluorescent lamps. Allows independent switching control of each lamp through use of two (2) electronic ballasts. Allows 50% power reduction when dual ballasts are independently wired and controlled. 19 House side shield not available on 5S and SL optics. 20 Order separately, replace XX with color suffix. 21 Use when mounting fixture heads at 90° increments. 22 For use in down lighting applications only. 23 Includes arm only. Must specify WRCP or WRCS in fixture ordering logic. Down light only.
24 Specifications and dimensions subject to change without notice.
•
•
•
•Optional Strut Rod and Clevis set for pole mount or wall mount
•Impact resistant 1/8" thick tempered clear flat glass
•Ballast and related electrical componentry are mounted to a reinforced one piece galvanized steel tray with integral handle
•Choice of two (2) high efficiency segmented optical systems constructed of premium 95% reflective anodized aluminum sheet
•
•Approximate net weight: 51 lbs. (23 kgs.)
COOPER LIGHTING