COOPER LIGHTING - LUMARK®

D I M E N S I O N SD E S C R I P T I O N

INDUSTRIAL

Maximum Height is

PD22=24 3/4" [629mm]

PD25=25" [635mm] Drop Bottom Adds

3 1/2" to Overall Height.

22" [559mm] 25" [635mm]

O R D E R I N G I N F O R M AT I O N

The BenchMark XB utilizes a durable heavy-duty die-cast aluminum ballast housing and prismatic acrylic refractor and drop refractor system for specification-level performance. U.L. listed and CSA certified. Standard damp location.

The BenchMark XB is perfect for applications requiring vertical and horizontal illumination on multiple surfaces, including fabrication, manufacturing, assembly areas and retail/commercial/ industrial warehousing where height restrictions must be considered and durability is desired.

P o w e r e d b y

t e c h n o l o g y

XB

PRISMATIC DIRECT-MOUNT BENCHMARK

1 7 5 - 4 0 0 W H i g h P r e s s u r e S o d i u m

P u l s e S t a r t M e t a l

H a l i d e

M e t a l

H a l i d e

H E AV Y- D U T Y D I R E C T M O U N T P R I S M AT I C L O W - B AY I N D U S T R I A L

S A M P L E N U M B E R : H P X B - D B 2 5 - 4 0 0 - 1 2 0 V

L U M I N A I R E

Lamp Type

Series

Refractor Type

HP=High

XB=Prismatic

DB=Prismatic Acrylic

Pressure

Direct-Mount

Refractor with Drop

Sodium 1

Benchmark

Acrylic Refractor

MH=Metal Halide 2

PD=Prismatic Acrylic

MP=Pulse Start MH (CWA) 2

Refractor

ML=Pulse Start MH (Linear Reactor) 2, 3

MD=Pulse Start Metal Halide (Electronic) 2, 4, 5, 6

Refractor Diameter 22=22"

25=25"

Lamp Wattage 175=175W 200=200W 250=250W 320=320W 350=350W 400=400W

Voltage 7 120V 208V 6 240V 6 277V 6 347V 480V

MT=Multi-Tap 8 TT=Triple-Tap 9 5T=5-Tap 10 E=Electronic 6

Options &

Accessories 11

(See Pages 541-545)

• Easy slide-on die-cast

aluminum mounting box

with tapped opening for

3/4" conduit

• Durable heavy-duty

die-cast aluminum

housing for lasting

performance in the

harshest environments.

Integrally hinged for

ease of maintenance with

optional toolless entry.

Finished in a standard

L A M P M O R T A L I T Y A N D L U M E N M A I N T E N A N C E C O M PA R I S O N S

LAMP MORTALITY

LUMEN MAINTENANCE

white polyester powder

paint

% Lamp Survival

100

90

80

70

60

50

40

30

20

10

0

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

20000

22000

24000

26000

28000

30000

 

 

 

 

 

 

 

Lamp Life [Hours]

 

 

 

 

 

 

 

 

 

Natural White TM & Uni-Form ® Pulse Start on ECON TECHNOLOGY

Uni-Form®Pulse Start on CWA

 

 

Probe Start Metal Halide on CWA

 

100

 

 

 

 

 

 

 

 

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

% Lumens

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

20000

• High power factor ballast

with class H insulation.

ECONTM electronic

ballast technology

delivers longer lamp life

and improved lumen

output while maintaining

a constant lamp wattage.

Minimum starting

temperature is -40°C

(-40°F) for HPS and -30°C

(-20°F) for MH

 

NOTE: Lamp Mortality and Lumen Maintenance Charts Courtesy of VENTURE®

Lamp Life [Hours]

 

 

 

 

90% Mean Lumens Nat-Wt-ECON

86% Mean Lumens-UPS-ECON

75% Mean Lumens-UPS CWA

 

 

 

 

65% Mean Lumens-Probe Start

 

 

Lamp

Ambient

Supply

 

 

Refractor

Wattage

Environment

Wire (Min.)

 

 

XB

175-400W

40°C (175-400W)

105°C

 

 

40°C (ECON)*

 

 

 

 

 

 

NOTES: * Electronic Pulse Start Metal Halide.

NOTES: 1 Not available in 175, 200, 320 or 350W. 2 Approved lamp containment barrier required when enclosed rated MP/ML/MH lamps are used. 2005 NEC code requires that open luminaires must utilize a safety glass bottom (SGB) or drop bottom (DB) accessory or an Open rated socket (OR) and lamp. 3 200, 250, 320, 350 & 400W Metal Halide Pulse Start. 277V only, not available in Q or EM option. 4 “MD” available 320, 350 or 400W MH Pulse Start. 5 Not available with HL or HC options. 6 MD available in 208, 240 or 277V or with “E” option which will operate voltages from 200-277V 50/60 Hz. 7 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 8 Multi-Tap ballast is 120/208/240/277V wired 277V.

9 Triple-Tap ballast is 120/277/347V wired 347V. 10 5-Tap ballast is 120/208/240/277/480V wired 480V. 400W MH only. 11 Add as suffix in the order shown.

12 Specifications and dimensions subject to change without notice.

Mogul-base porcelain

 

socket

Acrylic refractor system

 

mounts directly to

 

housing and provides full,

 

even illumination

Approximate net weight:

 

45 lbs. (20 kgs.)

COOPER LIGHTING

533

Page 1
Image 1
Cooper Lighting XB dimensions Easy slide-on die-cast, Aluminum mounting box, With tapped opening for, Conduit, Performance