Cornelius ENDURO-175 installation manual Flow Diagram B Models With Eight, Beverage Faucets

Models: ENDURO-175

1 18
Download 18 pages 61.57 Kb
Page 10
Image 10
FIGURE 6. FLOW DIAGRAM (B MODELS WITH EIGHT

620917902INS

8

FIGURE 6. FLOW DIAGRAM (B MODELS WITH EIGHT

FAUCETS VIEWED FROM FRONT OF UNIT

24

13

 

REGULATOR FOR

 

DIET OR

 

ROOT BEER

5–15

 

PSIG

15–50 PSIG

1

FAUCETS

1

2

S2

S3

S4

S1

 

S1

 

 

 

2

3

 

 

 

 

 

 

 

 

S2

 

 

 

3

4

 

 

 

 

 

 

 

 

S3

 

 

 

4

5

 

 

 

 

 

 

 

 

S4

 

 

 

5

6

 

 

 

 

 

 

 

 

S5

 

 

 

6

7

 

 

 

 

 

 

 

 

S6

 

 

 

7

8

 

 

 

 

 

 

 

 

S7

 

 

 

8

NON–CARB WATER

 

 

 

 

 

 

 

S8

 

 

 

S5

S6

REGULATORS

S7

S8

SYRUP

CO2 TANK

TANKS

FLAVOR TANKS 30 PSIG

F1 F2 F3 F4

BEVERAGE FAUCETS)

CARB WATER

 

WATER

 

MANIFOLD

CHECK

CARB WATER

VALVE

REMOTE

REFRIGERATION

SYSTEM

CARBONATOR

60–100 PSIG

CO2

OPTIONAL

PRESSURE

REGULATOR

POTABLE

WATER

SUPPLY

FILTER

ITEMS OUTSIDE BROKEN LINES ARE

NOT INCLUDED WITH UNIT.* – FOR NON–CARBONATED DRINK(S)/PLUG APPROPRIATE WATER MANIFOLD OUTLET.