Cornelius P/N 631500099 installation instructions Loose-Shipped Parts, Item No, Name

Models: P/N 631500116 P/N 631500108 P/N 631500074 P/N 631500099 P/N 631500109

1 4
Download 4 pages 58.7 Kb
Page 1
Image 1
These Bin Stat kits apply to all “X” Series Ice makers

IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234

Telephone (800) 238-3600

Facsimile (800) 535-4231

 

 

 

 

INSTALLATION INSTRUCTIONS, BIN STAT KIT, P/N 631500074, 631500099, 631500108, 631500109, AND 631500116

These Bin Stat kits apply to all “X” Series Ice makers

Table 1. Loose–Shipped Parts

Item No.

Part No.

Name

Qty.

1

630000837

Thermostat Asy

1

2

07578

Screw TC 08–32

2

3

630460162

Installation Instruction, Thermostat

1

4

630900895

Hex Nut 8–32 SS Keps

1

5

620045454 or

Bin Stat Support

1

 

620045455 or

 

 

620045456 or

620045457 or

620050327

1.Disconnect power.

2.Remove front cover of the unit and the electrical box cover plate. For 22” wide units you will need to remove the Grill from the right side of the unit.

3.To mount bin thermostat in electrical box:

A.Route wires and connector through grommet in electrical box (see Figure 1).

B.Attach bin thermostat to electrical box with two 08–32 TC screws provided (see Figure 1).

4.Connect the bin thermostat lead to the circuit board (see Figure 2).

5.Straighten approximately 12” of capillary tube to go through hole in chassis base. Re–coil the re- mainder. Do not disturb the tightly coiled end.

6.Insert the “1/4” diameter wire Bin Stat support into the coiled end of capillary tube. Carefully wrap 5 turns of free capillary tube tightly around the Bin Stat support. Insert the assembly through the hole in the chassis base. Route capillary tube to follow the Bin Stat support as closely as possible (see Figure 3).

7.Slip eye of Bin Stat support over the 8–32 weld stud in the chassis base. If a nut exists on this weld stud remove before assembling the Bin Stat support. Secure the Bin Stat support with the 8–32 Keps nut provided in the kit (see Figure 3).

8.Any excess capillary tubing must be carefully pulled back into the compressor compartment to pre- vent ice from damaging it during dispenser operation.

October 9, 2003

IMI CORNELIUS INC. 2001–20031630460162

Rev C

Page 1
Image 1