4.MINIMUM CHIMNEY HEIGHT: The chimney must be a minimum of 8’above top of fireplace. The chimney must extend a minimum of three feet above the highest point where it passes through the roof. Also, the chimney must be at least two feet higher than any portion of the building within ten feet.

5.MAXIMUM CHIMNEY HEIGHT: The chimney can be no taller than 50’ high as measured from the top of the Inglenook Fireplace anchor plate.

6.ELBOWS USED IN CHIMNEY CONSTRUCTION: A maximum of four thirty-degree elbows can be used in chimney construction as long as they are used in 2 sets offset from each other. Maximum offset is 4’.

If two thirty-degree elbows are used, the chimney must be a minimum of 12’ high. When four thirty-degree elbows are used, the chimney must be a minimum of 25’ high.

Follow all chimney manufacturers’ clearance recommendations for distances from combustible material and the location of support bracket requirements.

7.A chimney venting the Inglenook Fireplace shall not vent any other appliance.

WARNING: In cold areas, an air-cooled chimney may generate a large amount of water due to condensation. This water will accumulate on top of the fireplace and may cause corrosion. Country Flame Technologies Inc. cannot be held responsible for condensation/corrosion problems. In cold climates, Country Flame recommends the use of HT Listed UL103 2100° chimney.

8.A rain cap must be installed on top of the chimney. Failure to install a rain cap will cause corrosion of the chimney system and degrade its expected life and warranty.

9.FOLLOW THE CHIMNEY MANUFACTURER’S INSTALLATION PROCEDURES FOR PROPER CLEARANCES BETWEEN THE CHIMNEY AND ANY COMBUSTIBLE MATERIALS. Do not fill this space with insulation or any other combustible material.

10.Any portion of the chimney system that extends through a living (accessible) space must be enclosed to avoid contact with combustible materials, damage the chimney, or to prevent occupants from coming in contact with the chimney system.

CHIMNEY INSTALLATION INSTRUCTIONS

Cut and frame the required holes in the floors, ceilings, and roof where the chimney will be passing through.

REFER TO THE CHIMNEY MANUFACTURER’S INSTRUCTIONS FOR PROPER CLEARANCES REQUIRED BETWEEN CHIMNEY AND COMBUSTIBLES, REQUIRED SUPPORT BRACKETS, AND THE PROPER FRAMING REQUIRED AROUND THE CHIMNEY.

Install chimney sections, fire stops, attic insulation shields, and any other chimney parts per the manufacturer’s installation instructions.

Version: 7.0

33