4.MINIMUM CHIMNEY HEIGHT: The chimney must be a minimum of 8’above top of fireplace. The chimney must extend a minimum of three feet above the highest point where it passes through the roof. Also, the chimney must be at least two feet higher than any portion of the building within ten feet.
5.MAXIMUM CHIMNEY HEIGHT: The chimney can be no taller than 50’ high as measured from the top of the Inglenook Fireplace anchor plate.
6.ELBOWS USED IN CHIMNEY CONSTRUCTION: A maximum of four
If two
Follow all chimney manufacturers’ clearance recommendations for distances from combustible material and the location of support bracket requirements.
7.A chimney venting the Inglenook Fireplace shall not vent any other appliance.
WARNING: In cold areas, an
8.A rain cap must be installed on top of the chimney. Failure to install a rain cap will cause corrosion of the chimney system and degrade its expected life and warranty.
9.FOLLOW THE CHIMNEY MANUFACTURER’S INSTALLATION PROCEDURES FOR PROPER CLEARANCES BETWEEN THE CHIMNEY AND ANY COMBUSTIBLE MATERIALS. Do not fill this space with insulation or any other combustible material.
10.Any portion of the chimney system that extends through a living (accessible) space must be enclosed to avoid contact with combustible materials, damage the chimney, or to prevent occupants from coming in contact with the chimney system.
CHIMNEY INSTALLATION INSTRUCTIONS
Cut and frame the required holes in the floors, ceilings, and roof where the chimney will be passing through.
REFER TO THE CHIMNEY MANUFACTURER’S INSTRUCTIONS FOR PROPER CLEARANCES REQUIRED BETWEEN CHIMNEY AND COMBUSTIBLES, REQUIRED SUPPORT BRACKETS, AND THE PROPER FRAMING REQUIRED AROUND THE CHIMNEY.
Install chimney sections, fire stops, attic insulation shields, and any other chimney parts per the manufacturer’s installation instructions.
Version: 7.0 | 33 |