Water Filtration System Performance Data Sheet
Brand: Neos | Model: |
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53, and 58 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, and 58.
| Max. Allowable | Average | Average | Minimum | Average |
Substance | Concentration | Influent | Effluent | Percent | Percent |
| (mg/L) | (mg/L) | (mg/L) | Reduction (%) | Reduction (%) |
Arsenic (Pentavalant) | 0.010 | 0.05 | 0.006 | 79.1 | 87.7 |
Barium | 2.0 | 10 | 1.4 | 83.5 | 86.6 |
Radium 226/228 | 5pCi/L | 25pCi/L | 5pCi/L | N/A | N/A |
Cadmium | 0.005 | 0.031 | 0.002 | 89.0 | 92.7 |
Chromium (Hexavalent) | 0.1 | 0.358 | 0.023 | 93.8 | 95.1 |
Chromium (Trivalent) | 0.1 | 0.367 | 0.028 | 93.8 | 95.7 |
|
|
|
|
|
|
Lead | 0.010 | 0.153 | 0.005 | 93.6 | 95.1 |
|
|
|
|
|
|
Nitrate/Nitrite | 10 | 29.6 | 4.8 | 78.5 | 83.7 |
|
|
|
|
|
|
Selenium | 0.05 | 0.117 | 0.003 | 96.0 | 97.8 |
|
|
|
|
|
|
TDS | <187.5 | 741.5 | 57.8 | 91.5 | 92.2 |
Aesthetic Chlorine | ≥ 50% | 2.07 | 0.56 | 54.53 | 72.8 |
VOC* | ≥ 95% reduction | 0.32 | 0.0077 | 95.70 | 97.6 |
While testing was performed under laboratory conditions, actual performance may vary.
General Operating Information:
Rated Capacity | 165 gallons (for VOC) | |
4,400 gallons (for Aesthetic Chlorine) | ||
| ||
20 ~ 120 psi (1.4 ~ 8.4 kgf/cm2) | ||
41 ~ 95 ºF (5 ~ 35 ºC) | ||
Rated Service Flow | 0.07 GPM (for VOC) | |
0.5 GPM (for Aesthetic Chlorine) | ||
| ||
Daily Water Production Rate | 42 GPD | |
Product Efficiency Rating | 26.5 % |
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
• Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user responsibility, and parts and service availability.
• The influent water to the system shall include the following characteristics: o No organic solvents
o Chlorine: < 2 ppm
o pH: 7 - 8
o Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
o Iron: < 2 ppm
o Turbidity: < 1 NTU
oHardness: < 1000 mg/L
21