INSTALLATION STEP 7
Install the Door Control
Locate door control within sight of door, at a minimum height of 5 feet (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" (0.40 cm) holes and use the anchors provided. For
1. Strip 7/16" (11 mm) of insulation from one end of |
bell wire and connect to the two screw terminals on |
back of door control by color: white wire to 2 and |
white/red wire to the 1. |
2. Remove white cover by gently prying at slot in top |
of the cover with a small flat head screwdriver. |
Fasten with 6AB x |
(drywall installation) or |
(into gang box) as follows: |
• Drill and install bottom screw, allowing 1/8" (3 mm) |
to protrude above wall surface. |
• Position bottom of door control on screw head and |
slide down to secure. Adjust screw for snug fit. |
• Drill and install top screw with care to avoid |
cracking plastic housing. Do not over tighten. |
• Insert top tabs and snap on cover. |
3. (Standard installation only) Run bell wire up wall |
and across ceiling to motor unit. Use insulated |
staples to secure wire in several places. Do not |
pierce wire with a staple, creating a short or open |
circuit. If your access door is near the garage door, |
you may run this wire with the Safety Reversing |
WARNING
To prevent possible SERIOUS INJURY or DEATH from electrocution:
•Be sure power is not connected BEFORE installing door control.
•Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
•Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet, and away from all moving parts of door.
•NEVER permit children to operate or play with door control push buttons or remote control transmitters.
•Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
•ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.
Hardware Shown Actual Size6AB x | Insulated | |
Staples | ||
(drywall installation) | ||
| ||
| ||
(gang box installation) | Dry Wall Anchors |
To opener
| Sensor wires along the top of the rail. See page 18. |
4. | Insert all wires through the opening on top of motor |
| unit above the terminal block on the back panel |
| (Figure 3). |
5. | Strip 7/16" (11 mm) of insulation from each set of |
| wires. Insert door control wire into |
| terminals by color: white wire to white, white/red |
PREMIUM CONTROL CONSOLE
Lighted
Push
Button
LIGHT
LOCK
Top
Mounting Hole
WHITE
2Terminal
| Screws | |
| RED | |
| 1 | |
Light | Bottom | |
Lock | Mounting Hole | |
BACK VIEW | ||
|
wire to red. |
Figure 1 | Figure 2 |
Separate white and white/black wires sufficiently to |
connect to the opener |
like colored wires together. Insert wires into quick- |
connect holes: white to white and white/black to |
grey. |
NOTE: When connecting multiple door controls to the opener, twist same color wires together. Insert wires into
REMOVE & REPLACE COVER | ||
To Replace, | To Remove, | INSTALLATION |
| ||
Insert Top | Twist |
|
Tabs First | Here |
|
| LIGHT |
|
| LOCK |
|
24 Volt
6.Use tacks or staples to permanently attach entrapment warning label to wall near door control, and manual release/safety reverse test label in a prominent location on inside of garage door.
NOTE: DO NOT connect the power and operate the opener at this time. The trolley will travel
to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.
Strip 7/16" (11 mm) of insulation from each wire. |
| |||
Insert wires through opening on top of motor | To | To | ||
unit above terminal block, then into quick- | Sensors | |||
Door | ||||
connect terminals. |
| |||
Control |
| |||
|
|
| ||
Door Control | To release wire, push in tab |
|
| |
Connections | with screwdriver tip |
|
| |
|
|
| Quick- | |
|
|
| Connect | |
Red White Grey |
| Terminal | ||
|
|