Install the Door Control

Locate door control within sight of door, at a minimum height of 5 feet (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" (0.40 cm) holes and use the anchors provided. For pre-wired installations (as in new home construction), it may be mounted to a single gang box (Figure 2).

1. Strip 7/16" (11 mm) of insulation from one end of

bell wire and connect to the two screw terminals on

back of door control by color: white wire to 2 and

white/red wire to the 1.

2. Remove white cover by gently prying at slot in top

of the cover with a small flat head screwdriver.

Fasten with 6AB x 1-1/4" self-tapping screws

(drywall installation) or 6-32 x 1" machine screws

(into gang box) as follows:

• Drill and install bottom screw, allowing 1/8" (3 mm)

to protrude above wall surface.

• Position bottom of door control on screw head and

slide down to secure. Adjust screw for snug fit.

• Drill and install top screw with care to avoid

cracking plastic housing. Do not over tighten.

• Insert top tabs and snap on cover.

3. (Standard installation only) Run bell wire up wall

and across ceiling to motor unit. Use insulated

staples to secure wire in several places. Do not

pierce wire with a staple, creating a short or open

circuit. If your access door is near the garage door,

you may run this wire with the Safety Reversing

WARNING

To prevent possible SERIOUS INJURY or DEATH from electrocution:

Be sure power is not connected BEFORE installing door control.

Connect ONLY to 24 VOLT low voltage wires.

To prevent possible SERIOUS INJURY or DEATH from a closing garage door:

Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet, and away from all moving parts of door.

NEVER permit children to operate or play with door control push buttons or remote control transmitters.

Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.

ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.

Hardware Shown Actual Size

6AB x 1-1/4" Screw

Insulated

Staples

(drywall installation)

 

6-32 x 1" Screw

 

(gang box installation)

Dry Wall Anchors

Outside Keylock Accessory Connections

To opener quick-connect terminals: white to white; white/red to red.

 

Sensor wires along the top of the rail. See page 18.

4.

Insert all wires through the opening on top of motor

 

unit above the terminal block on the back panel

 

(Figure 3).

5.

Strip 7/16" (11 mm) of insulation from each set of

 

wires. Insert door control wire into quick-connect

 

terminals by color: white wire to white, white/red

PREMIUM CONTROL CONSOLE

Lighted

Push

Button

LIGHT

LOCK

Top

Mounting Hole

WHITE

2Terminal

 

Screws

 

RED

 

1

Light

Bottom

Lock

Mounting Hole

BACK VIEW

 

wire to red.

Figure 1

Figure 2

Separate white and white/black wires sufficiently to

connect to the opener quick-connect terminals. Twist

like colored wires together. Insert wires into quick-

connect holes: white to white and white/black to

grey.

NOTE: When connecting multiple door controls to the opener, twist same color wires together. Insert wires into quick-connect holes: white to white and red/white to red.

REMOVE & REPLACE COVER

PRE-WIRED

To Replace,

To Remove,

INSTALLATION

 

Insert Top

Twist

 

Tabs First

Here

 

 

LIGHT

 

 

LOCK

 

Figure 3 Wiring to Terminal Block

24 Volt

2-Conductor Bell Wire in Gang Box

6.Use tacks or staples to permanently attach entrapment warning label to wall near door control, and manual release/safety reverse test label in a prominent location on inside of garage door.

NOTE: DO NOT connect the power and operate the opener at this time. The trolley will travel

to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.

Strip 7/16" (11 mm) of insulation from each wire.

 

Insert wires through opening on top of motor

To

To

unit above terminal block, then into quick-

Sensors

Door

connect terminals.

 

Control

 

 

 

 

Door Control

To release wire, push in tab

 

 

Connections

with screwdriver tip

 

 

 

 

 

Quick-

 

 

 

Connect

Red White Grey

 