SEARSELECTRONICINSECT KILLER - MODEL NO. 833.14334
REF. NO. | PART NO. |
| DESCRIPTION | QTY. | |
1 | 554 | 722 | HANGING | RING | 1 |
2 | 596 | 1565 P02 | THREADED | NIPPLE, 1" LONG | 1 |
3 | 567 | 420 | NEOPRENE | WASHER | 1 |
4 | 596 | 784 | REDUCING | BUSHING | 1 |
5 | 555 | 5314 SR | HOOD |
| I |
6245 6260 P27 THREAD CUTTING SCREW, F,
7 | 596 | 785 |
| LOCKNUT |
|
| 1 |
8 | 544 | 5288 |
| GRID SPACER |
| 5 | |
9 | 544 | 3750 |
| SPACER INSULATOR | 2 | ||
10 | 245 | 6245 | P28 | SHEET METAL | SCREW_ NO. 8 x 1/2 | 9 | |
11 | 532 | 30O6 |
| BALLAST |
|
| 2 |
12 | 576 | 4890 |
| TRANSFORMER |
| 1 | |
13 | 505 | 3370 |
| BULB SOCKET | ASSY | 2 | |
14 | 552 3369 | P03 | REFLECTOR |
|
| 2 | |
15 | 555 3534 |
| BULB RETAINER | 1 | |||
16 | 512 392 P26 | BULB BOOT WIRE, 26';LONG | 2 | ||||
17 | 552 5202 |
| TOP PLATE |
|
| 1 | |
18 | 531 2034 |
| STARTER |
|
| 2 | |
19 | 512 5140 |
| POWER CORD |
| 1 | ||
20 | 571 5170 |
| STARTER SOCKET | 2 | |||
21 | 245 6236 | Pll | SHEET METAL | SCREW, NO. 6 x 3/8 | 3 | ||
22 | 544 3749 |
| MOUNTING | INSULATOR | 3 | ||
23 | 245 6245 | P12 | SHEET METAL | SCREW, NO. 6 x 1/2 | 3 | ||
24 | 512 404 P02 | HV GRID WIRE |
| 2 | |||
25 | 530 2815 | S | BULB, BLACK | LIGHT | 2 | ||
26 | 553 2846 | P01 | INNER GRID |
|
| 1 | |
27 | 553 2847 | P01 | OUTER GRID |
| 1 | ||
28 | 505 3377 |
| BASKET ASSY |
| 1 | ||
29 | 5O54031 |
| PHOTOCELL | ASSY | 1 |
30245 6260 P25 THREAD CUTTING SCREW, F,
31 557 5199 | OWNER'SMANUAL | 1 |
5
26
|
|
|
| 15 |
| TROUBLESHOOTING | AND REPAIR | ANALYSIS | |
PROBLEM | POSSIBLE CAUSE |
|
| CORRECTION |
A. Bulbs do not light | I. No electrical power. | 1. | Check | fuse or circuit breaker. |
and no high voltage |
| 2. | Check | extension cord, (If used,) |
|
|
|
|
on grid.
B. Bulbs light but no
grid high voltage.
C. Grid voltage present but bulbs do not
light.
O. Intermittent or
continuous sparking
between grids.
1. Shorted grids.
1, Lamp(s) not seated properly.
2.Starter defective.
3.
1.Gap between grids is too small.
2.Grid clogged with foreign material.
3.Grid not seated in insulaitor.
1.Examine grids to see if inner and outer grids are free from foreign material, dirt or a
2.Check to make sure inner grid _nd outer grid
are not touching. Use insulated screwdriver.
1.Check all sockets for proper seating and
alignment. | ,, |
2. Replace if needed. | ,' |
3.Replace if needed.
1.Unplug unit and adjust grids by bending
back into alignment using screwdriver blade.
2.Clean grid using an air blower.
3.Look for proper grid seating at all insulators,
Any problems you encounter that are not corrected by the action recommended in this chart should be referred to your nearest Sears Service Center.