Craftsman 557-5199, 833.14334 owner manual Searselectronicinsect Killer - Model No

Models: 557-5199 833.14334

1 6
Download 6 pages 19.62 Kb
Page 5
Image 5
SEARSELECTRONICINSECT KILLER - MODEL NO. 833.14334

SEARSELECTRONICINSECT KILLER - MODEL NO. 833.14334

REF. NO.

PART NO.

 

DESCRIPTION

QTY.

1

554

722

HANGING

RING

1

2

596

1565 P02

THREADED

NIPPLE, 1" LONG

1

3

567

420

NEOPRENE

WASHER

1

4

596

784

REDUCING

BUSHING

1

5

555

5314 SR

HOOD

 

I

6245 6260 P27 THREAD CUTTING SCREW, F, 8-32 x 3/8 4

7

596

785

 

LOCKNUT

 

 

1

8

544

5288

 

GRID SPACER

 

5

9

544

3750

 

SPACER INSULATOR

2

10

245

6245

P28

SHEET METAL

SCREW_ NO. 8 x 1/2

9

11

532

30O6

 

BALLAST

 

 

2

12

576

4890

 

TRANSFORMER

 

1

13

505

3370

 

BULB SOCKET

ASSY

2

14

552 3369

P03

REFLECTOR

 

 

2

15

555 3534

 

BULB RETAINER

1

16

512 392 P26

BULB BOOT WIRE, 26';LONG

2

17

552 5202

 

TOP PLATE

 

 

1

18

531 2034

 

STARTER

 

 

2

19

512 5140

 

POWER CORD

 

1

20

571 5170

 

STARTER SOCKET

2

21

245 6236

Pll

SHEET METAL

SCREW, NO. 6 x 3/8

3

22

544 3749

 

MOUNTING

INSULATOR

3

23

245 6245

P12

SHEET METAL

SCREW, NO. 6 x 1/2

3

24

512 404 P02

HV GRID WIRE

 

2

25

530 2815

S

BULB, BLACK

LIGHT

2

26

553 2846

P01

INNER GRID

 

 

1

27

553 2847

P01

OUTER GRID

 

1

28

505 3377

 

BASKET ASSY

 

1

29

5O54031

 

PHOTOCELL

ASSY

1

30245 6260 P25 THREAD CUTTING SCREW, F, 8-32 x 1/4 2

31 557 5199

OWNER'SMANUAL

1

5

26

 

 

 

 

15

 

TROUBLESHOOTING

AND REPAIR

ANALYSIS

PROBLEM

POSSIBLE CAUSE

 

 

CORRECTION

A. Bulbs do not light

I. No electrical power.

1.

Check

fuse or circuit breaker.

and no high voltage

 

2.

Check

extension cord, (If used,)

 

 

 

 

on grid.

B. Bulbs light but no

grid high voltage.

C. Grid voltage present but bulbs do not

light.

O. Intermittent or

continuous sparking

between grids.

1. Shorted grids.

1, Lamp(s) not seated properly.

2.Starter defective.

3.Burned-out bulb(s).

1.Gap between grids is too small.

2.Grid clogged with foreign material.

3.Grid not seated in insulaitor.

1.Examine grids to see if inner and outer grids are free from foreign material, dirt or a build-up of dead insects.

2.Check to make sure inner grid _nd outer grid

are not touching. Use insulated screwdriver.

1.Check all sockets for proper seating and

alignment.

,,

2. Replace if needed.

,'

3.Replace if needed.

1.Unplug unit and adjust grids by bending

back into alignment using screwdriver blade.

2.Clean grid using an air blower.

3.Look for proper grid seating at all insulators,

Any problems you encounter that are not corrected by the action recommended in this chart should be referred to your nearest Sears Service Center.

Page 5
Image 5
Craftsman 557-5199, 833.14334 owner manual Searselectronicinsect Killer - Model No