PROBLEM | CAUSE |
| CORRECTION | |||
Excessive tank | Pressure switch does |
| Move On/Auto/Off lever to | |||
pressure - safety | not shut off motor when |
| the "Off" position, if the | |||
valve pops off. | compressor reaches "cut- |
| outfit does not shut off | |||
| out" pressure. |
| contact a Trained Service | |||
|
|
| Technician. | |||
| Pressure switch |
| Contact a Trained Service | |||
| too high. |
| Technician. | |||
|
|
|
|
|
|
|
Air leaks at | Tube fittings are not tight |
| Tighten fittings where air | |||
fittings. | enough. |
| can be heard escaping. | |||
|
|
| Check fittings with soapy | |||
|
|
| water solution. Do Not | |||
|
|
| Overtighten. | |||
Air leaks in air | Defective air tank. |
| Air tank must be replaced. | |||
tank or at air |
|
| Do not repair the leak. | |||
tank welds. |
|
|
|
|
| Risk of |
|
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
|
| Bursting |
|
|
|
|
|
| |
|
|
| Do not drill into, weld or | |||
|
|
| otherwise modify air tank | |||
|
|
| or it will weaken. The tank | |||
|
|
| can rupture or explode. | |||
Air leaks | Leaking seal. |
| Contact a Trained Service | |||
between head |
|
| Technician. | |||
and valve plate. |
|
|
|
|
|
|
Air leak from | Possible defect in safety |
| Operate safety valve | |||
safety valve. | valve. |
| manually by pulling on ring. | |||
|
|
| If valve still leaks, it should | |||
|
|
| be replaced. | |||
|
|
| ||||
Knocking Noise. | Possible defect in safety | Operate safety valve | ||||
| valve. | manually by pulling on ring. | ||||
|
| If valve still leaks, it should | ||||
|
| be replaced. | ||||
|
|
|
|
|
|
|