Drain
Valve

How to Use Your Unit

How to Stop:

1. Set the On/Auto/Off lever to “OFF”.

Before Starting

Break-in Procedure

Serious damage may result if the following break-in instructions are

not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "OFF" position.

NOTE: If hose end adapter was replaced with quick connect, pull coupler back until it clicks to prevent air from escaping through the quick connect.

Hose End

Adapter

On/Auto/Off

Regulator

Switch

 

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Open the drain valve fully (counter-clock- wise) to permit air to

escape and prevent air pressure build up in

the air tank during the break-in period.

4.Move the On/Auto/Off lever to "ON/AUTO" posi- tion. The compressor will start.

5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, move the On/Auto/Off lever to "OFF" position and close the drain valve (clock- wise).

7.Move the On/Auto/Off lever to "ON/AUTO" posi- tion. The air receiver will fill to “cut-out” pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up

1.Place On/Auto/Off lever to “OFF”.

2.Pull regulator knob out, turn counter-clockwise until it stops. Push knob in to lock in place.

3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect.

Too much air pressure causes a hazardous risk of

bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start

1.Turn the On/Auto/Off lever to “AUTO” and allow tank pressure to build. Motor will stop when tank pressure reaches “cut-out” pressure.

2.Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place. The com- pressor is ready for use.

NOTE: Always operate the air compressor in well- ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area.

11 - ENG