SERVICE AND ADJUSTMENTS

Unit cycles automatically when

power is on. When doing Maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY A TRAINED SERVICE TECHNICIAN.

Before servicing: Unplug or disconnect electrical supply to the air compressor. Bleed tank of pressure

Allow the air compressor to cool.

To Replace or Clean Check Valve

1.Release all air pressure from air tank. See “To Drain Tank" in the Maintenance section.

2.Unplug unit.

Check

Valve

3.Remove the hose by removing the hose clamp.

NOTE: The hose clamp is not reusable. You must purchase a new hose clamp, see the Parts List Manual or purchase a standard hose clamp at a local hardware store.

4.Unscrew the check valve (turn counter-clockwise) using a socket wrench.

5.Make sure the valve disc moves freely inside the check valve and the spring holds the disc in the upper, closed position. The check valve may be cleaned with a solvent, such as paint and varnish remover.

6.Apply sealant to the check valve threads. Reinstall the check valve (turn clockwise).

7.Replace hose and new hose clamp.

8.Perform the Break-in Procedure. See "Break-in Procedure" in the Operation section.

Hose Clamp

D27446

16- ENG

Page 16
Image 16
Craftsman 919.724572 owner manual Service and Adjustments, To Replace or Clean Check Valve, Hose Clamp