ing unit from dolly
For removing, read steps below first before attempting to remove or replace the air compressor to the dolly:
Do not use the dolly for any other means other than transporting this aurcompressor.
Do not move air compressor/dolly combo without tightening the knob that safely secures the compressor to the dolly.
Removing the air compressor from the doily:
1.The air compressor should be turned off and unplugged from the power source.
2.Turn the knob on the bottom of the dolly counter° clockwise until the knob releases from the air
compressor. (This should be 1°2 revolutions)
3.While holding the dolly cart handle with one hand, rift up on the air compressor handle to remove the compressor.
Reattaching the air compressor to the dolly: 1, The air compressor should be turned off and
unplugged from the power source.
2.Align the compressor's rubber isolators with the depressions in the dolly frame.
3.insert knob bolt into the air compressor and rotate clock°wise until tight. (if the compressor is not properly aligned onto the frame the knob will not tighten. Reposition compressor and try again.)
NOTE: Any service procedure not covered in the maintenance schedule should be performed by qualified service personnel.
The air compressor should be turned off, unplugged from the power source, air bled from the tank and allowed time to cool before any maintenance is performed.
To ensure efficient operation and longer life of the air compressor unit, a routine maintenance schedule should be followed. The following schedule is geared toward a consumer whose compressor is used in a normal working environment on a daily basis.
%
Items to | Check/Change | Before | each | use | |||
or | daity |
| |||||
|
|
|
|
| |||
Check | Tank | Safety | Valve |
| X |
| |
Overall | Unit | Visual | Check |
| X |
| |
Check | Air Filter |
|
| X |
| ||
Drain Tank |
|
|
| X |
| ||
Check Power Cord for Damage |
| X |
| ||||
Change Oil |
|
| after first | 50 hours | |||
|
| after every | 100 | hours | |||
|
|
|
| ||||
Check | Oil Level |
|
| X |
|
Storage
For storing the air compressor, be sure to do the following:
1. | Turn the unit off and unplug the power cord from the | 4. | Open | the | drain | valve to bleed all air from the tank. |
| receptacle. | 5. | Close | the drain | valve. | |
2. | Remove all air hoses, accessories, and air tools from | 6. | Store | the | air compressor in a clean and dry location. | |
| the air compressor. |
|
|
|
|
|