Creda Heating Solution manual Sizing Guide, Storage and panel heaters, Technical Specification

Models: Heating Solution

1 48
Download 48 pages 13.51 Kb
Page 44
Image 44
Sizing Guide

Sizing Guide

Storage and panel heaters

To use these tables, select the type of heater and the appropriate sizing guide table. Then read across from the nearest floor area and appropriate external wall length to where the columns intersect. There are two temperature options given in each table:

Comfort - approximately 21°C for living areas

Background - approximately 18°C, typically required in bedrooms

Choose either comfort or background heating for the suggested heater size.

These tables are based on conventionally constructed single or two storey dwellings within:

Ceiling heights of 2.5m (8ft)

Roof insulation of 25mm (1in) thick

Brick cavity walls with no insulation

An external temperature of -1°C

Technical Specification

Tables for storage and storage fan heaters also assume the use of 7 hour economy tariff electricity.

Please check your tariff and metering requirements with either your electricity supplier or call the Creda Technical Centre on 08709 000430.

Storage heaters

Product Selector

Floor

Temperature

 

 

 

 

 

 

 

Total Length of Outside Wall (m)

 

 

 

 

 

 

 

 

Area m2

Options

1.5m

2m

3m

4m

5m

6m

7m

8m

9m

10m

11m

12m

13m

14m

15m

16m

17m

18m

19m

20m

Up to

Comfort

S/XS

S

S

M

M

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3m2

Background

S/XS

S/XS

S

S

S

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Up to

Comfort

S

M

M

M

L

L

L

L

 

 

 

 

 

 

 

 

 

 

 

 

6m2

Background

S

S

S

S

M

M

M

M

 

 

 

 

 

 

 

 

 

 

 

 

Up to

Comfort

S

M

M

L

L

L

L

MS

SM

2M

 

 

 

 

 

 

 

 

 

 

9m2

Background

S

S

M

M

M

M

M

L

L

L

 

 

 

 

 

 

 

 

 

 

Up to

Comfort

M

M

L

L

L

MS

MS

MS

2M

2M

2M

LM

 

 

 

 

 

 

 

 

12m2

Background

S

M

M

M

M

L

L

L

L

MS

MS

MS

 

 

 

 

 

 

 

 

Up to

Comfort

L

L

L

L

MS

MS

2M

2M

2M

LM

LM

2L

2L

 

 

 

 

 

 

 

15 m2

Background

M

M

M

M

L

L

L

MS

MS

MS

2M

2M

LM

 

 

 

 

 

 

 

Up to

Comfort

L

L

L

MS

MS

2M

2M

2M

LM

LM

2L

2L

2L

3M

3M

 

 

 

 

 

18m2

Background

M

M

M

L

L

L

MS

MS

MS

MS

2M

2M

2M

2M

LM

 

 

 

 

 

Up to

Comfort

L

L

MS

MS

2M

2M

2M

LM

LM

2L

2L

2L

3M

3M

3M

2L+S

 

 

 

 

21m2

Background

M

M

L

L

L

MS

MS

MS

MS

2M

2M

2M

2M

LM

LM

LM

 

 

 

 

Up to

Comfort

L

MS

MS

2M

2M

2M

LM

LM

2L

2L

2L

3M

3M

3M

2L+S

2L+S

2L+S

 

 

 

24m2

Background

M

L

L

L

MS

MS

MS

MS

2M

2M

2M

LM

LM

ML

2L

2L

2L

 

 

 

Up to

Comfort

MS

MS

2M

2M

2M

LM

LM

2L

2L

2L

2L

3M

3M

3M

2L+S

2L+S

2L+M

2L+M

 

 

27m2

Background

L

L

L

MS

MS

MS

MS

2M

2M

2M

LM

LM

LM

2L

2L

2L

2L

2L

 

 

Up to

Comfort

2M

2M

2M

LM

LM

2L

2L

2L

2L

2L+S

2L+S

2L+S

2L+S

2L+M

2L+M

2L+M

2L+M

3L

3L

3L

30m2

Background

L

L

MS

MS

MS

2M

2M

2M

2M

2M

LM

LM

2L

2L

2L

2L

2L

3M

3M

3M

Storage fan heaters

Up to

Comfort

18

18

18

18

18

18

 

 

 

 

 

 

 

 

 

 

 

 

3m2

Background

18

18

18

18

18

18

 

 

 

 

 

 

 

 

 

 

 

 

Up to

Comfort

18

18

18

18

24

24

24

24

 

 

 

 

 

 

 

 

 

 

6m2

Background

18

18

18

18

18

18

18

18

 

 

 

 

 

 

 

 

 

 

Up to

Comfort

18

18

18

24

24

24

24

18+S

18+S

18+S

 

 

 

 

 

 

 

 

9m2

Background

18

18

18

18

18

18

18

24

24

24

 

 

 

 

 

 

 

 

Up to

Comfort

18

18

24

24

24

18+S

18+S

18+S

18+M

18+M

18+M

18+M

 

 

 

 

 

 

12m2

Background

18

18

18

18

18

24

24

24

24

18+S

18+S

18+S

 

 

 

 

 

 

Up to

Comfort

24

24

24

24

18+S

18+S

18+S

18+S

18+M

24+M

24+M

24+M

24+L

 

 

 

 

 

15m2

Background

18

18

18

18

24

24

24

24

18+S

18+S

18+S

18+M

18+M

 

 

 

 

 

Up to

Comfort

24

24

24

18+S 18+S

18+S

18+M

18+M

24+M

24+M

24+L

24+L

24+L

24+L

24+L

 

 

 

18m2

Background

18

18

18

24

24

24

24

18+S

18+S

18+S

18+M

18+M

18+M

18+M

24+M

 

 

 

Up to

Comfort

24

24

18+S

18+S 18+S

18+S

18+M

18+M

18+M

24+M

24+M

24+L

24+L

24+L

18+2M 18+2M

 

 

21m2

Background

18

18

24

24

24

24

18+S

18+S

18+S

18+M

18+M

18+M

24+M

24+M

24+M

24+M

 

 

Up to

Comfort

24

24

18+S

18+S 18+S

18+M

18+M

24+M

24+M

24+L

24+L

24+L

18+2M 18+2M 24+2M 24+2M 24+2M

 

24m2

Background

18

24

24

24

24

18+S

18+S

18+S

18+M

18+M

18+M

24+M

24+M

24+M

24+L

24+L

24+L

 

Up to

Comfort

18+S

18+S

18+S

18+M 18+M

18+M

24+M

24+M

24+L

24+L

24+L

18+2M 18+2M 18+2M 18+2M 24+2M 24+2M

 

27m2

Background

24

24

24

24

18+S

18+S

18+S

18+M

18+M

18+M

24+M

24+M

24+M

24+L

24+L

24+L

24+L

24+L

Up to

Comfort

18+M

18+M

18+M

24+M 24+M

24+L

24+L

24+L

24+L

18+2M 18+2M 18+2M 18+2M 18+2M 24+2M 24+2M 24+2M 24+2L 24+2L 24+2L

30m2

Background

24

24

24

18+S 18+S

18+M

18+M

18+M

18+M

18+M

24+M

24+M

24+L

24+L

24+L

24+L

24+L

18+2M 18+2M 18+2M

Panel heaters

Up to

Comfort

600

600

1000

1000

1250

1250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3m2

Background

600

600

600

1000

1000

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Up to

Comfort

600

1000

1000

1250

1250

1500

1500

2000

 

 

 

 

 

 

 

 

 

 

 

 

6m2

Background

600

600

1000

1000

1000

1250

1250

1500

 

 

 

 

 

 

 

 

 

 

 

 

Up to

Comfort

1000

1000

1250

1250

1500

1500

2000

2000

2000

2250

 

 

 

 

 

 

 

 

 

 

9m2

Background

1000

1000

1000

1250

1250

1250

1500

1500

2000

2000

 

 

 

 

 

 

 

 

 

 

Up to

Comfort

1250

1250

1250

1500

1500

2000

2000

2000

2250

2500

2500

2500

 

 

 

 

 

 

 

 

12m2

Background

1000

1000

1250

1250

1250

1500

1500

1500

2000

2000

2000

2000

 

 

 

 

 

 

 

 

Up to

Comfort

1250

1250

1500

1500

2000

2000

2250

2250

2500

2500

2750

3000

3000

 

 

 

 

 

 

 

15m2

Background

1000

1250

1250

1500

1500

1500

2000

2000

2000

2250

2500

2500

2500

 

 

 

 

 

 

 

Up to

Comfort

1500

1500

2000

2000

2000

2250

2500

2500

2500

2750

3000

3000

3250

3500

3500

 

 

 

 

 

18m2

Background

1250

1250

1250

1500

1500

1500

2000

2000

2250

2250

2500

2500

2500

2500

2750

 

 

 

 

 

Up to

Comfort

1500

2000

2000

2000

2250

2250

2500

2500

2750

3000

3000

3250

3500

3500

4000

4000

 

 

 

 

21m2

Background

1250

1500

1500

1500

2000

2000

2000

2000

2250

2250

2500

2500

2750

2750

3000

3000

 

 

 

 

Up to

Comfort

2000

2000

2000

2250

2500

2500

2750

2750

3000

3000

3250

3500

3500

4000

4000

4000

4000

 

 

 

24m2

Background

1500

1500

2000

2000

2000

2000

2250

2250

2500

2500

2500

2750

2750

3000

3000

3250

3250

 

 

 

Up to

Comfort

2000

2000

2250

2500

2500

2750

3000

3000

3250

3500

3500

4000

4000

4000

4100

4400

4400

4750

 

 

27m2

Background

1500

1500

2000

2000

2000

2000

2250

2500

2500

2500

2750

2750

3000

3000

3250

3250

3500

3500

 

 

Up to

Comfort

2250

2500

2500

2500

2750

3000

3000

3250

3250

3500

3500

4000

4000

4000

4100

4400

4400

4750

4750

5000

30m2

Background

2000

2000

2000

2000

2000

2250

2500

2500

2500

2750

2750

3000

3000

3250

3250

3500

3500

4000

4000

4000

Extra Small (XS) = TSR6 = 0.9kW

 

Small (S) = TSR12 = 1.7kW

Medium (M) = TSR18 = 2.5kW

 

Large (L) = TSR24 = 3.4kW

 

 

 

 

 

44

+44 (0) 1733 456789

www.creda-heating.co.uk

Page 44
Image 44
Creda Heating Solution Sizing Guide, Storage and panel heaters, Technical Specification, Storage heaters, Product Selector