Creda S710E Electrical Connection, Supply cable installation, Earth “E”, Neutral “N”, Live “L”

Models: S710E

1 12
Download 12 pages 20.64 Kb
Page 9
Image 9
Electrical Connection

Electrical Connection

Supply cable installation

The electrcic hobs are supplied without cable. Use a cable:

H05 VV-F 3x2.5mm2

Open the terminal box by removing the "V" screw and taking off the cover.

The wires in the mains lead are coloured in accordance with the following code:

Green & Yellow

- Earth E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blue

- Neutral N

Brown

- Live L

Connect the wires in accordance with the following diagram

1 2 3 4 5

LN

Fix the cable in place with the "F" cable clamp, close the lid and fasten it with the "V" screw.

Connecting the supply cord to the electrical mains: The hob must be connected to the mains by a double pole mains switch, which must have a minimum 0f 3mm space between the contacts, correctly fused with a capacity appropriate to that shown on the hob Rating Plate. All electrical wiring from the consumer unit to the appliance, via the switched double pole cooker outlet, must be of an acceptable type and current rating as above.

The supply cord should conform to BS6004 conductor size 4mm2, must be positioned so that no part of it reaches a temperature of 50° C above room temperature. The electrical installation must comply with the IEE Regulations, Building Regulation & local By-Laws.

Before making the connection, make sure that:

the limiter switch (fuse) and the residual wiring can support the appliance load (see the rating plate).

the mains system is properly earthed in compliance with current regulations and provisions.

there is easy access to the socket or the double pole switch after the appliance is installed.

IMPORTANT:

If the hob is installed above a built-in oven, the electrical connection for the hob must be independent of that for the oven, both for safety reasons and to facilitate the removal of the oven for maintenance, repair etc.

V

1

2

3

4

5

 

 

 

 

F

Voltage and frequency of power supply:

240V~ 50/60Hz 5600W

9