be too long to be displayed across the top line of the LCD screen; use << and >> to
scroll left and right respectively or examine them through Crestron Toolbox. Users
may wish to periodically save the error log to a file. This can be an invaluable aid in
troubleshooting problems with the control system. Refer to the Crestron Toolbox
help file for details.
The CLEAR button can to used to empty the error log and extinguish the MSG front
panel LED. A security message prompts the user to confirm the command.
NOTE: The up and down menu selection buttons to the right of the LCD screen
may be used in lieu of the NEXT and PREV menu function buttons.
MSG Submenu with Sample Message
TIME
This menu can only be obtained by entering the correct access code. The default
access code is 1234. To assign a unique access code, use the following procedures:
1. Establish communication with the control system (refer to “Establishing
Communication” on page 16).
2. Launch the Crestron Toolbox and display the “System Info” window by
selecting Tools | System Info (or by clicking the icon).
3. Select Functions | Display Message to bring up the “Display Message”
window.
“Display Message” Window
4. Click the “Password” button to open the “Front Panel Password” window.