Pressing a RESET button during normal operations shuts off a channel for as long as
the button is held down. If the button is released, the channel turns on.

System Details

In the event that the full 300 watts (12.5 amps) of the supply is exceeded, all eight
channels turn off simultaneously, the eight red channel overload LEDs (OVRLD)
illuminate, and the red system overload LED (OVRLD) illuminates. Pressing the
system RESET button causes the unit to reset each channel individually until all
channels are active (assuming the overload has been removed). Pressing the system
RESET button during normal operations causes the unit to shut down all channels
and turn them back on when the button is released.
Specifications
Specifications for the C2N-SPWS300 are listed in the following table.
C2N-SPWS300 Specifications
SPECIFICATION DETAILS
Input Power1 100 VAC to 240 VAC, 4 A, 50/60 Hz
Output Voltage 24 VDC (regulated)
Output Fuse Rating 4 A, 125 V, Time Delay, 1 fuse per channel
(not serviceable)
Ripple/Noise Less than 150 mV
Default NET ID 15
Control System Update Files 2, 3, 4
2-Series Control System Update
File
CNMSX-AV/Pro Update File
CNRACKX/-DP Update File
ST-CP Update File
CEN/CN-TVAV Update File
Version 2.004.CUZ or later
Version 5.12.63X.UPZ or later
Version 5.12.63W.UPZ or later
Version 4.02.4S.UPZ or later
Version 5.12.63V.UPZ or later
C2N-SPWS300 Firmware C2N-SPWS300.v1.3.upg or later
Rack Space Required 3U high, 1U wide
Operating Temperature 41° to 104°F (5° to 40°C)
Humidity 10% to 90% RH (non-condensing)
Dimensions Height: 5.19 in (13.18 cm)
Width: 13.25 in (33.66 cm)
Depth: 3.29 in (8.36 cm)
Weight 5.3 lb (2.4 kg)
1 The C2N-SPWS300 ships with two cable assemblies; one for domestic use and the other for
international use or installation within the Crestron CAEN.
2 The latest versions can be obtained from the Downloads | Software Updates section of the Crestron
website (www.crestron.com). Refer to NOTE after the last footnote.
3 Crestron 2-Series control systems include the AV2, AV2 with Card Cage, CP2, CP2E, PAC2, MP2,
MP2E, PRO2, and RACK2.
4 Filenames for CNX and ST-CP update files have a UPZ extension. Files on the website may be .zip
or self-extracting .exe files containing the .cuz or .upz file. All can be obtained from the Downloads
section of the Crestron website. To avoid program problems, make sure you are using the update file
with the correct suffix letter (e.g., S, V, W, X)
NOTE: Crestron software and any files on the website are for Authorized Crestron
dealers and Crestron Authorized Independent Programmers (CAIP) only. New users
may be required to register to obtain access to certain areas of the site (including the
FTP site).