Crestron C2N-VEQ4 Cresnet 4-Channel Digital Volume Control
Operations Guide - DOC. 6135A Cresnet 4-Channel Digital Volume Control: C2N-VEQ4 15
Expanded PRO2 System Tree
C2Net Device Slot in Configuration Manager
To incorporate a C2N-VEQ4 into the system, drag the C2N-VEQ4 from the Cresnet
Control Modules | Cresnet Audio Modules folder of the Device Library and drop it in
System Views. The PRO2 system tree displays the C2N-VEQ4 in Slot 9, with a
default Net ID of 12 as shown in the following illustration.
NOTE: The first C2N-VEQ4 in a system is preset with a Net ID of 12 when its
symbol is dragged into the upper pane of System Views. Additional units are assigned
different Net ID numbers as they are added.
C2Net Device, Slot 9
Setting the Net ID in Device Settings
Double-click the C2N-VEQ4 icon to open the “Device Settings” window. This
window displays the C2N-VEQ4 device information. If necessary, select the Net ID
tab to change the unit’s Net ID, as shown in the following figure.
C2N-VEQ4 “Device Settings” Window