InfiNET EX™ Gateway Crestron CEN-RFGW-EX
Identity Code Net ID The Net ID of the CEN-RFGW-EX has been factory set to 2F. The Net
IDs of multiple CEN-RFGW-EX devices in the same system must be
unique. Net IDs are changed from a personal computer (PC) via Crestron
Toolbox™ (refer to “Establishing Communication” which starts on page
20).
When setting the Net ID, consider the following:
• The Net ID of each unit must match an ID code specified in the
SIMPL™ Windows® program.
• Each network device must have a unique Net ID.
For more details, refer to the Crestron Toolbox help file.
IP ID The IP ID is set within the CEN-RFGW-EX’s table using Crestron
Toolbox. For information on setting an IP table, refer to the Crestron
Toolbox help file. The IP IDs of multiple CEN-RFGW-EX devices in the
same system must be unique.
When setting the IP ID, consider the following:
• The IP ID of each unit must match an IP ID specified in the
SIMPL™ Windows® program.
• Each device using IP to communicate with a control system must
have a unique IP ID.
12 • infiNET EX™ Gateway: CEN-RFGW-EX Operations & Installation Guide – DOC. 6706A