Professional Video Distribution Switch Crestron CNX-PVID8x3
14 Professional Video Distribution Switch: CNX-PVID8x3 Operations Guide - DOC. 8159A
The unit should be mounted at the bottom of the rack if it is the only
unit in the rack.
When mounting this unit in a partially filled rack, load the rack from
the bottom to the top with the heaviest component at the bottom of the
rack.
If the rack is provided with stabilizing devices, install the stabilizers
before mounting or servicing the units in the rack.
NOTE: If rack mounting is not required, rubber feet are provided for tabletop
mounting or stacking. Apply the feet near the corner edges on the underside of the
unit. Refer to "Stacking" on page 14 for details.
NOTE: Reliable grounding of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct
connections to the branch circuit (e.g., use of power strips).
Two "ears" are provided with the CNX-PVID8x3 so that the unit can be rack
mounted. These ears must be installed prior to mounting. Complete the procedure
below to attach ears to the CNX-PVID8x3. The only tool required for this procedure
is a #2 Phillips screwdriver.
1. Position a rack ear so that its drilled holes align with the four vacant
holes located on one side of the CNX-PVID8x3.
2. Use four screws (supplied, #6-32, 3/8"L) to secure the ear to the
CNX-PVID8x3, as shown in the following diagram.
Ear Attachment for Rack Mounting (Side View of Unit)
FASTEN EACH EAR
WITH FOUR
SCREWS (SUPPLIED)
3. Tighten screws to finger-tight, then, using a #2 Phillips screwdriver,
tighten an additional 1/8-turn.
4. Repeat procedure (steps 1 and 2) to attach ear to the other side.
5. If the rear panel of the CNX-PVID8x3 is accessible when mounted in
the rack, install the CNX-PVID8x3. If the rear panel is NOT accessible,
perform the hookup procedure before rack installation.
Stacking
Four "feet" are provided with the CNX-PVID8x3 so that if the unit is not rack
mounted, the rubber feet can provide stability when placed on a flat surface or
stacked. These feet should be attached prior to the hookup procedure. Refer to the
following illustration for placement of the feet.