PROCISE™ Surround Sound Amplifier Crestron PROAMP(I)-7X400
Operation
Turn Power On or Off To turn the amplifier power on, move the switch on the front of the amplifier to the
position.
To turn the power off, move the switch on the front of the amplifier to the
position. The amplifier’s microprocessor will reset and continue to receive power.
Clear Fault Indicator In the event a channel detects overcurrent, over/under voltage, channel temperature,
or DC offset volta ge, its FAULT LED will light. To clear the FAULT LED, press
the recessed RESET button on the front of the amplifier.
NOTE: Before pressing RESET, verify that the cause of the fault is no longer
present.
Reset Circuit Breaker The amplifier is equipped with two circuit breakers that will open in the event an
internal short is detected. To reset a breaker, turn off the amplifier power as
described above, then press the breaker’s reset button on the rear of the amplifier.
NOTE: Before resetting the breaker, verify that the cause of the short is no longer
present.
22 • PROCISE™ Surround Sound Amplifier: PROAMP(I)-7X400 Operations Guide – DOC. 6976A