Four-Way Amplified Splitter Crestron SRD-SPL-4

Industry Compliance

As of the date of manufacture, the SRD-SPL-4 has been tested and found
to comply with specifications for CE marking and standards per EMC
and Radiocommunications Compliance Labelling.

Installation

Installation of the SRD-SPL-4 splitter consists of the following. Refer
also to the “Block Diagram” on page 2.
Attach the RG-6 cable from the antenna to the port labeled IN on the
splitter.
Attach RG-6 cables (up to 70 ft) to the splitter OUT ports and route
them to the radios. Use the four supplied 3-foot cables to adapt the
F-male connector on the RG-6 cables to the SMB-jacks on the radios.
NOTE: For best results in all configurations, use quad-shielded RG-6
cable whenever possible.
4 Four-Way Amplified Splitter: SRD-SPL-4 Installation Guide – DOC. 6727A