CT-1610
esigned from the ground up exclusively Dfor the professional sound contractor,
The
In a profession where unplanned service calls quickly wipe out profits,
For more details about the Crown
Specifications
The following applies to
C O M - T E C H ® S E R I E S
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
Features | • IOC® (Input/Output Comparator) circuitry im- | |||||
• Unique power supply allows channels to be | mediately alerts of any distortion exceeding | |||||
| independently operated in either | 0.05%, providing dynamic proof of distortion- | ||||
| ohm mode. | free performance. | ||||
• Remote feature allows amplifier to be turned | • Enhanced PIP2™ (Programmable Input Pro- | |||||
| on and off from a remote location by adding | cessor) connector accepts new accessory | ||||
| an optional R.S.V.P. accessory. | modules that tailor the amplifier to suit spe- | ||||
• Crown’s Grounded Bridge™ design delivers | cific applications. | |||||
• Full protection from shorted, open and mis- | ||||||
| large voltage swings without using easily | |||||
| stressed | matched loads; general overheating; DC; | ||||
| conventional amplifiers. The results are | |||||
| lower distortion and superior reliability. | from internal fault are provided by our latest | ||||
• Patented ODEP® (Output Device Emulation | protection scheme: | |||||
• Three Year | ||||||
| Protection) circuitry compensates for over- | |||||
| heating and overload to keep the amplifier | protects your investment and guarantees its | ||||
| working when others would fail. | specifications. | ||||
|
|
|
|
|
|
gain unless otherwise specified. Specifications for units supplied outside the U.S.A. may vary slightly at different AC voltages and frequencies.
Power
Output Power
| *1 kHz **20 | |
Power | Power | |
870W | 810W | |
540W | 520W | |
960W | 910W | |
1,745W | 1,595W | |
1,780W |
| |
1,805W | 1,725W |
*1 kHz Power: refers to maximum average power in watts at 1 kHz with 0.1% THD.
**20
Load Impedance: Safe with all types of loads. With
Voltage Gain to 1 kHz,
85:1 ±12% or 35 dB ±1 dB gain at
Voltage Gain to 1 kHz,
90:1 ±12% or 39 dB ±1 dB gain at
Required AC Mains:
AC Line Current,
Current, voltage and frequency requirements are provided on the unit’s back panel.
At Idle: All units draw 35 watts or less when idle (in
AC Line Connector: NEMA
Performance
Frequency Response: ±0.1 dB from 20 Hz to
20 kHz at 1 watt.
Phase Response: ±10 degrees from 10 Hz to 20 kHz at 1 watt.
105 dB below rated 1 kHz power.
Total Harmonic Distortion (THD): 1 kHz rated power, 0.05% or less true THD.
Intermodulation Distortion (IMD): (60 Hz and 7 kHz at 4:1) Less than 0.05% from rated power to 35 dB below rated power at 8 ohms.
Damping Factor: Greater than 1,000 from 10 Hz to 400 Hz.
Controlled Slew Rate: (Slew rates are limited to useful levels for ultrasonic/RF protection.) Greater than 17 volts per microsecond.
Controls
Enable: A
Level: A
Sensitivity: A
Dual/Mono: A
Reset: A
Indicators
Enable: An amber
Signal: A green
IOC: An amber