-10-
A. Local Power (see figure 3-3).
In this system, power is supplied to the
AR2000-M device by connecting it to a 120VAC or
240VAC supply in the immediate vicinity of the
device. An input selector switch is provided and must
be set to the appropriate input voltage prior to
turning the device on.
3-7. POWER CONNECTIONS.
The two basic methods of supplying power to an
Audio Router device are 120VAC 50/60Hz Local
Power or 240VAC 50/60Hz Local Power and 24VDC
Backup Power. The following paragraphs describe
each method along with the advantages and disad-
vantages of each.
LOW (-) WHT
HI (+) WHT
AM25CK
SIGNAL LINES
SHIELDED
TWISTED PAIR
SIGNAL LINES
SHIELDED
TWISTED PAIR
300GC
MODEL AR2000-M WITH MODEL 300GC
CONNECTIONS USING INTERNAL AMPLIFIER
AM25CK
120VAC 120VAC
AM25CK
120VAC
AM25CK
120VAC
AM25CK
300GC 300GC 300GC 300GC
120VAC
AM25CK
120VAC
AM25CK
120VAC120VAC
AM25CK
300GC 300GC 300GC
290A4120-05
B
AUDIO OUT
PRESET 7
DRY CONTACT IN (N.O.)
+
ALARM
INDICATOR
-
- +
ZONE 3
PRESET 3
DRY CONTACT IN (N.O.)
- +
ZONE 1
PRESET 1
GND +24V
POWER OUT
TO PRESET
ABOVE
GND +24V
- +
ZONE 2
AUDIO OUT
PRESET 2
- +
ZONE 4
PRESET 4
- +
ZONE 5 - +
ZONE 6
PRESET 5 PRESET 6
- +
CH B INPUT
CH B INPUT
VOLUME
MICROPHONE
VOLUME
AUDIO IN FROM EXTERNAL AMP
OR FROM AUDIO OUT 15W
- +
ZONE 7 - +
ZONE 8
PRESET 8
AUDIO OUT
TO BELOW
- +
- +
ALL CALL
OPTO
COMMON +24V
AUDIO OUT
CONTROL OUT
TO ZONE
PHONE LINE
NUMBER
( )
25Vrms
AUDIO OUT(15W)
70Vrms
- +
AUDIO OUT
1Vrms
25V
rms
70V
rms
1V
rms
25V
rms
70V
rms
1V
rms
SELECT
VOLUME
CONTROL IN
FROM PRESET PHONE
VOLUME
CH B
- +
CH A INPUT
SELECT
CH A INPUT
VOLUME
SELECT
CH A
MONITOR
SPEAKER
VOLUME
(CLASS 2) POWER
OUT TO AR2000-P
(CLASS 2)
POWER OUT
TO AR2000-Z
CAUTION: TO REDUCE
THE RISK OF FIRE,
REPLACE ONLY WITH
BUSS 250V, 4A GMT FUSE
(CLASS 2)24VDC
BACKUP POWER
120 VAC, 50/60 HZ, 2A
240 VAC, 50/60 HZ, 1A
CAUTION: TO REDUCE THE RISK OF FIRE,
REPLACE ONLY WITH GMC 2A, 250V FUSE
WARNING:
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED PERSONNEL. TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK,
DO NOT REMOVE COVER OR EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
Figure 3-1.
AUDIO OUT
PRESET 7
DRY CONTACT IN (N.O.)
+
ALARM
INDICATOR
-
- +
ZONE 3
PRESET 3
DRY CONTACT IN (N.O.)
- +
ZONE 1
PRESET 1
GND +24V
POWER OUT
TO PRESET
ABOVE
GND +24V
- +
ZONE 2
AUDIO OUT
PRESET 2
- +
ZONE 4
PRESET 4
- +
ZONE 5 - +
ZONE 6
PRESET 5 PRESET 6
- +
CH B INPUT
CH B INPUT
VOLUME
MICROPHONE
VOLUME
AUDIO IN FROM EXTERNAL AMP
OR FROM AUDIO OUT 15W
- +
ZONE 7 - +
ZONE 8
PRESET 8
AUDIO OUT
TO BELOW
- +
- +
ALL CALL
OPTO
COMMON +24V
AUDIO OUT
CONTROL OUT
TO ZONE
PHONE LINE
NUMBER
( )
25Vrms
AUDIO OUT(15W)
70Vrms
- +
AUDIO OUT
1Vrms
25V
rms
70V
rms
1V
rms
25V
rms
70V
rms
1V
rms
SELECT
VOLUME
CONTROL IN
FROM PRESET PHONE
VOLUME
CH B
- +
CH A INPUT
SELECT
CH A INPUT
VOLUME
SELECT
CH A
MONITOR
SPEAKER
VOLUME
(CLASS 2) POWER
OUT TO AR2000-P
(CLASS 2)
POWER OUT
TO AR2000-Z
CAUTION: TO REDUCE
THE RISK OF FIRE,
REPLACE ONLY WITH
BUSS 250V, 4A GMT FUSE
(CLASS 2)24VDC
BACKUP POWER
120 VAC, 50/60 HZ, 2A
240 VAC, 50/60 HZ, 1A
CAUTION: TO REDUCE THE RISK OF FIRE,
REPLACE ONLY WITH GMC 2A, 250V FUSE
WARNING:
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED PERSONNEL. TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK,
DO NOT REMOVE COVER OR EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
LOW (-) WHT
HI (+) WHT
AM25CK
SIGNAL LINES
SHIELDED
TWISTED PAIR
300GC
MODEL AR2000-M WITH MODEL 300GC
CONNECTIONS USING EXTERNAL AMPLIFIER
AM25CK
120VAC 120VAC
AM25CK
120VAC
AM25CK
120VAC
AM25CK
300GC 300GC 300GC 300GC
120VAC
AM25CK
120VAC
AM25CK
120VAC120VAC
AM25CK
300GC 300GC 300GC
290A4120-06
B
HP440
AMP
OUTPUT AMP
INPUT
Figure 3-2.