STUDIO REFERENCE I
S T U D I O R E F E R E N C E S E R I E S
Architectural & Engineering Specifications
Studio Reference I (120 V, 60 Hz models)
The Crown® Studio Reference I power amplifier shall be a
The outputs shall be switchable as stereo,
The output impedance of each channel shall be less than 10 milliohms in series with less than 2 microhenries in stereo mode.
The variable impedance power supplies shall reduce unnecessary voltage across the output devices by automatically switching to a parallel mode when less voltage is required by the output circuitry and to a series mode when more voltage is required.
The amplifier shall contain protection circuitry which limits the drive level placed on the output devices before their SOA (Safe Operating Area) is exceeded. This protec- tion circuitry shall calculate the instantaneous voltage across and current through the output devices while factoring in their simulated junction temperatures to predict how close they are to their operating limits. This protection will be called “ODEP.”
The amplifier shall contain controlled
The amplifier shall temporarily go into a
Internal controls shall include an input sensitivity switch to select between 0.775 V, 1.4 V or a fixed voltage gain of 26 dB for full rated output.
A Crown P.I.P. and
Front panel indicators shall include an amber power enable indicator, an amber ODEP protection system indicator for each channel which shall normally be illuminated
to confirm the availability of reserve thermodynamic energy and which shall dim in proportion to limiting when the power demands of the output stages have been exceeded, a green IOC indicator for each channel, and a green Signal indicator for each channel which shall normally flash at moderate intensity to show the presence of an audio signal.
The power amplifier shall meet or exceed the following performance criteria. Input sensitivity for rated output: 26 dB voltage gain (unbalanced). Rated FTC output in stereo mode with less than 0.1% THD: 780watts per channel (20 Hz to 20 kHz) into
8 ohms. Hum and noise: at least 120 dB (A weighted) below full rated output power.
Phase response: +5 to
response: 20 Hz to 20 kHz, 0.1 dB at 1 watt into 8 ohms per channel in stereo mode.
Damping factor: greater than 20,000 from 10 to 200 Hz into 8 ohms. Intermodulation
distortion (SMPTE): less than 0.005% from full bandwidth power to 78 watts rising
linearly to better than 70 dB at 20 kHz. Harmonic distortion: less than 0.02% at rated
The amplifier shall be safe when driving any kind of
The power requirements shall be 120 VAC at 60 Hz. At idle, the amplifier shall draw 90 watts or less.
The amplifier chassis shall be constructed of steel with a durable black finish and shall be designed for
The dimensions of the amplifier shall allow for 19 inch (48.3 cm) EIA standard (RS-
The amplifier shall weigh 60 pounds, 11 ounces (27.6 kg) and shall have a center of gravity approximately 6 inches (15.2 cm) behind the front panel.
The amplifier shall be designated the Crown Studio Reference I.
Crown International 1718 W. Mishawaka Rd. Elkhart, IN
Specifications subject to change without prior notice. Latest information available at www.crownaudio.com.
Crown and Crown Audio are registered trademarks of Crown International, Inc. Printed in U.S.A.
© 2005 Crown Audio®, Inc.
04/05 |