Cyberdata VOIP Indoor Paging Speaker SIP device Setup Notes
The following steps show h ow to program the Cyberdata Indoor Speaker to interconnect with the 3300
ICP.
For more detailed configur ation or questions about the Cyberdata Indoor Speaker click on the following
link: http://www.cyberdata.net/support/voip/ceilingspeaker.html
Step 1
Plug network cable into the RJ-45 ja ck at back of Speaker. The speaker must be plugged into a network
switch port that is supplying Powe r over Ethernet.
Step 2
The default IP address of the speaker is 192.168.3.10. Press the RTFM button on the front of the speaker
with a paper clip of thumbtack. This should read back its IP address to confirm.
Access the Configuration Portal:
http://192.168.3.10
Username: admin
Password: admin
Step 3
Click “Network Setup”. Set “IP Addressing” to “DHCP” or if you prefer you can use static IP addressing.
When you save settings the speaker will reboot.
Document #09-5159-00034 Page 13