BATTERY REPLACEMENT AND STORAGE

CAUTION! Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery.

Service the battery under the supervision of personnel knowledgeable of batteries and their precautions. Keep unauthorized personnel away from batteries. If you have questions, contact your dealer or call the number in this manual for information on battery replacement.

CAUTION! Use only the specified type of battery. See your dealer for replacement batteries. CAUTION! The battery may present the risk of electrical shock. Do not dispose of batteries in a fire, as it may explode. Follow all local ordinances regarding proper disposal of batteries. CAUTION! Do not open or mutilate the batteries. Release electrolyte is harmful to the skin and eyes and may be toxic.

CAUTION! A battery can present a high risk of short circuit current and electrical shock. Take the following precautions before replacing the battery:

1.Remove all watches, rings or other metal objects.

2.Only use tools with insulated handles.

3.DO NOT lay tools or other metal parts on top of battery or any battery terminals.

4.Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of ground. CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK! The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance (applicable to a UPS and a remote battery supply not having a grounded circuit).

5.Batteries are consider HAZARDOUS WASTE and must be disposed of properly. Contact your local government for more information about proper disposal and recycling of batteries.

6.Turn off and unplug all connected equipment.

7.Turn the UPS off and unplug it from the AC power source.

BATTERY REPLACEMENT PROCEDURE:

1. Remove the right side front panel.

2. Remove the two retaining screws of the cable protection cover then remove the cover.

3. Disconnect the black and red cable.

4. Remove the four retaining screws.

5. Pull the battery pack out from the unit.

6. Slide a new battery pack into the unit. Assemble the screws, cover, cable and front panel in the reverse sequence of above steps.

REMINDER: Recharge the unit for 4 – 8 hours to ensure the UPS performs expected runtime.

STORAGE

First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables connected to the UPS to avoid battery drain. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to insure battery life. If the battery remains uncharged for an extended period of time, it may suffer permanent loss of

TROUBLE SHOOTING

 

Problem

 

Possible Cause

 

Solution

 

 

The UPS does not

 

Batteries are not fully charged.

 

Recharge the battery by leaving the UPS plugged

 

 

 

 

in.

 

 

perform expected

 

 

 

 

 

 

 

 

Contact Cyber Power Systems at

 

 

runtime.

 

Battery is slightly worn out.

 

 

 

 

 

service@cyberpower-eu.com

 

 

 

 

 

 

 

 

 

 

The on/off switch is designed to

 

Turn the UPS off. Wait 10 seconds and then turn

 

 

 

 

prevent damage by rapidly

 

 

 

 

 

 

the UPS on.

 

 

 

 

turning it off and on.

 

 

 

 

 

 

 

 

 

The UPS will not

 

The unit is not connected to an

 

The unit must be connected to a 220-240V

 

 

turn on.

 

AC outlet.

 

50/60Hz outlet.

 

 

 

 

The battery is worn out.

 

Contact Cyber Power Systems at

 

 

 

 

 

service@cyberpower-eu.com

 

 

 

 

 

 

 

 

 

 

Mechanical problem.

 

Contact Cyber Power Systems at

 

 

 

 

 

service@cyberpower-eu.com

 

 

 

 

 

 

 

 

 

 

Circuit breaker is tripped due to

 

Turn the UPS off and unplug at least one piece of

 

 

 

 

 

equipment. Wait 10 seconds, reset the circuit

 

 

Outlets do not

 

overload.

 

 

 

 

 

breaker and then turn the UPS on.

 

 

 

 

 

 

 

provide power to

 

 

 

 

 

 

 

Batteries are discharged

 

Allow the unit to recharge for at least 4 hours.

 

 

equipment

 

 

 

 

 

 

 

 

 

 

 

 

Unit has been damaged by a

 

Contact Cyber Power Systems at

 

 

 

 

surge or spike.

 

service@cyberpower-eu.com

 

 

 

 

The serial/USB cable is not

 

Connect the serial/USB cable to the UPS unit and

 

 

 

 

 

an open serial port on the back of the computer.

 

 

 

 

connected.

 

 

 

 

 

 

You must use the cable that came with the unit.

 

 

 

 

 

 

 

 

PowerPanel

 

The serial/USB cable is

 

Try another serial/USB port of your computer.

 

 

Business Edition

 

connected to the wrong port.

 

 

 

 

 

 

 

 

or PowerPanel is

 

The unit is not providing battery

 

Shut down your computer and turn the UPS off.

 

 

inactive (all icons

 

 

Wait 10 seconds and turn the UPS back on. This

 

 

are gray).

 

power.

 

should reset the unit.

 

 

 

 

The serial cable is not the cable

 

You must use the cable included with the unit for

 

 

 

 

that was provided with the unit.

 

the software.

 

TECHNICAL SPECIFICATIONS

 

Model

PR1500E

 

PR2200E

Capacity

(VA)

1500VA

 

2200VA

Capacity

(Watts)

1000W

 

1600W

Input

 

 

 

 

Input Voltage Range

220-240Vac

 

Frequency Range

50/60 Hz

 

Output

 

 

 

 

On Battery Output Voltage

Pure Sine Wave at 230Vac +/- 7%

On Battery Output Frequency

50/60 Hz

 

Overload Protection

On Utility: Circuit Breaker, On Battery: internal current limiting

Surge Protection and Filtering

 

 

 

Lightning / Surge Protection

Yes

 

Network Protection

RJ45 (One In/One Out)

 

Physical

 

 

 

 

Total # of UPS Receptacles

6

 

 

Maximum Dimensions

43.3cm*8.8cm*38.8cm

 

Weight (Kg)

26.4

 

32.1

Battery

 

 

 

 

Sealed Maintenance Free Lead Acid

12V / 7AHx4

 

12V / 9AHx4

Battery

 

 

 

 

 

 

User Replaceable

Yes, Hot Swappable Battery Pack

Typical Recharge Time

8 Hours

 

Warning Diagnostics

 

 

 

Indicators

 

Power On, Using Battery, AVR, Load Level, Battery Level

Audible Alarms

On Battery, Low Battery, Overload, Self-test

Environmental

 

 

 

Operating Temperature

+32°F to 95°F ( 0°C to 35°C )

Operating Relative Humidity

0 to 95% NON-CONDENSING

Communication

 

 

 

PowerPanel Business edition

Windows 98/ME/2000/NT/XP, Server 2003

Software

 

 

 

 

 

Management

 

 

 

Auto-Charger

Yes

 

Auto-Restart

Yes

 

USB

 

Yes

 

SNMP/HTTP network function

Optional

 

DEFINITIONS FOR ILLUMINATED LED INDICATORS

 

 

 

Using

Circuit

 

Condition

Power

AVR

Alarm

 

On

Battery Breaker

 

 

On

Off

Off

Set

Off

Normal

 

On

Slow

Off

Set

Off

AVR- Max. boost 13% of input voltage for output

 

regulation while input voltage is from 8% to 15% under

 

flash

 

 

 

 

 

nominal.

 

 

 

 

 

 

 

On

Rapid

Off

Set

Off

AVR- Max. boost 26% of input voltage for output

 

regulation while input voltage is from 15% to 26% under

 

flash

 

 

 

 

 

nominal.

 

 

 

 

 

 

 

ON

On

Off

Set

Off

AVR- Max. buck 11% of input voltage for output regulation

 

while input voltage is from 8% to 26% over nominal.

 

 

 

 

 

 

 

Off

Off

On

Set

Two

Utility Failure- The UPS is providing battery power to the

 

Beeps

outlets.

 

 

 

 

 

 

Off

Off

On

Set

Rapid

Utility Failure- The UPS is providing battery power.

 

Rapid beeps indicate the battery will run out of charge

 

Beeps

 

 

 

 

 

within a few minutes.

 

 

 

 

 

 

On/Off

On/ Off

On/Off

Set

Long

Overload- Please turn the UPS off and unplug at least one

piece of equipment from the UPS. Wait 5 seconds, reset

/Flash

Beep

capacity.

Input

AVR Switch

Battery

Charger

Block Diagram

Transformer Output

Battery

 

Inverter

 

(DC/AC)

 

 

 

 

 

 

 

 

 

 

the circuit breaker and restart the UPS.

Off

Off

On

Up

Long

Overload- Please turn the UPS off and unplug at least one

piece of equipment from the UPS. Wait 5 seconds, reset

Beep

 

 

 

 

the circuit breaker and restart the UPS.

 

 

 

 

 

Off

Off

Off

Set

Off

Surge Protection Malfunction- Power surge has

damaged the unit. Please contact CyberPower Systems.

 

 

 

 

 

For more information, visit eu.cyberpowersystems.com or contact

CyberPower Systems B.V. Flight Forum 3545,5657DW Eindhoven,The Netherlands Tel: + 31(0)40 2348170, Fax : + 31(0)40 2340314, E-MAIL: sales@cyberpower-eu.com CyberPower Systems Inc. (USA) 4241 12th Avenue East Suite 400 Shakopee, MN 55379 , U.S.A.

Tel: +1 952 4039500, Fax: +1 952 4030009, E-MAIL: sales@cyberpowersystems.com

Entire contents copyright ©2004 CyberPower Systems B.V., All rights reserved. Reproduction in whole or in part without permission is prohibited.

PowerPanel and PowerPanel Plus are trademarks of CyberPower Systems (USA) Inc.

CyberPower warrants to you, the original purchaser, that CyberPower UPS will be free from defects in design, assembly, materials and workmanship for two years ( battery is only one year) from the date of original purchase. Any warranty services, please contact your local dealers or distributors.

Page 2
Image 2
CyberPower Systems 2200VA user manual Battery Replacement Procedure, Storage