CyberPower Systems BR650ELCD Functional Test, AC Mode, On-Battery Mode, Routine Maintenance

Models: BR850ELCD BR650ELCD BR450ELCD

1 2
Download 2 pages 59.74 Kb
Page 2
Image 2
Functional Test

Functional Test

AC Mode

The UPS delivers power to the loads derived from the utility and maintains proper battery charge. It also regulates the output voltage to within a narrow range.

On-Battery Mode

The UPS operates on battery when the line voltage or frequency has fallen outside the limits. Local users are alerted to this mode of operation by visual and audible indicators. The UPS provides power to the load from the battery and through its inverter and the output voltage and frequency of the UPS are regulated within a narrow range

1.Switch On

Press the power switch on the top panel then the “power on” LED will light up.

2.Switch Off

Press again the power switch, the “power on” LED on the top panel will go off.

3.Cold Start / Start on Battery:

This UPS can be turned on even when AC is not present.

Press the power switch on the top panel then the “power on” LED will light up.

ROUTINE MAINTENANCE AND STORAGE

ROUTINE MAINTENANCE

1.Use dry soft clothes to clean the top panel and plastic parts. Do not use any detergent that contains alcoholic ingredient.

2.The expected lifetime of the battery is around 3 years. Improper operation and harsh environment will reduce the actual lifetime.

3.Unplug the UPS from power inlet if the UPS will not operate for long period of time.

STORAGE

1.First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables connected the UPS to avoid battery drain.

2.The UPS should be stored in a cool dry location.

3.Make sure the battery is fully charged before the UPS is stored.

4.For extended storage in moderate climates, the battery should be charged for 12 hours every 3 months by plugging the power cord into the wall receptacle. Repeat it every 2 months in high temperature locations.

TROUBLE SHOOTING

Problem

Possible Cause

Solution

The UPS does

The battery is not fully

Recharge the battery by leaving the UPS

charged.

plugged in.

not perform

expected

The battery is slightly worn

Contact CyberPower Systems at

runtime.

out.

service@cyberpower-eu.com

 

 

 

 

 

The on/off switch is

Turn the UPS off. Wait 10 seconds and

 

designed to prevent

 

damage by rapidly turning it

then turn the UPS on.

 

off and on.

 

The UPS will not

The unit is not connected to

The unit must be connected to a

turn on.

an AC outlet.

220-240V 50/60Hz outlet.

 

The battery is worn out.

Contact CyberPower Systems at

 

service@cyberpower-eu.com

 

 

 

Mechanical problem.

Contact CyberPower Systems at

 

service@cyberpower-eu.com

 

 

 

 

Turn the UPS off and unplug at least one

 

 

piece connected equipment. Unplug the

 

 

power cord of the UPS then remove the

 

The circuit breaker is

fuse compartment beneath the power inlet

 

of the UPS and replace the blown fuse

 

tripped due to overload.

 

with a spare one. Lock the compartment

 

 

Outlets do not

 

back to the UPS. Connect power cord

provide power to

 

then turn the UPS on. Make sure that your

equipment

 

spare fuse meets the specification.

The battery is discharged

Allow the unit to recharge for at least 4

 

 

hours.

 

 

 

 

 

 

The unit has been damaged

Contact CyberPower Systems at

 

by a surge or spike.

service@cyberpower-eu.com

 

 

 

 

The USB cable is not

Connect the USB cable to the UPS unit

 

and an open serial port on the back of

 

connected.

the computer. You must use the cable

 

 

that came with the unit.

PowerPanel®

The USB cable is

Try another USB port of your computer.

connected to the wrong

Personal Edition

port.

 

is inactive (all

 

 

 

Shutdown your computer and turn the

icons are gray).

The unit is not providing

UPS off. Wait 10 seconds and turn the

 

battery power.

 

UPS back on. This should reset the unit.

 

 

 

The serial cable is not the

You must use the cable included with the

 

cable that was provided with

 

unit for the software.

 

the unit.

 

 

TECHNICAL SPECIFICATIONS

Model

 

BR 450ELCD

 

BR 650ELCD

 

BR 850ELCD

Capacity

(VA)

450VA

 

650VA

 

850VA

Capacity

(Watts)

270W

 

390W

 

510W

Input

 

 

 

 

 

 

Input Voltage Range

 

 

165-270Vac

 

Frequency Range

 

50/60 Hz+/-3Hz (Auto Sensing)

 

Output

 

 

 

 

 

On Battery Output

Simulated Sine Wave at 230Vac +/-10%

Voltage

 

 

 

 

 

On Battery Output

 

 

50/60 Hz +/-1%

 

Frequency

 

 

 

 

 

 

 

 

Overload Protection

 

 

Yes

 

Physical

 

 

 

 

 

Total # of UPS

Schuko*6 (3 for battery backup and surge ;3 for surge )

Receptacles

 

 

 

 

 

Dimensions(mm)

 

271(L) x160.7(W) x113.6(H)

 

Weight (kg)

4.4

 

5.5

 

6.4

 

 

 

 

 

 

Battery

 

 

 

 

 

Sealed Maintenance

12V / 4.5Ah x1

 

12V / 7Ah x1

 

12V / 9Ah x1

Free Lead Acid Battery

 

 

 

 

 

 

 

Typical Recharge Time

 

 

8 Hours

 

 

Warning Diagnostics

 

 

 

 

 

Indicators

 

 

Power On

 

Audible Alarms

On Battery, Low Battery, Overload

 

Environmental

 

 

 

 

 

Operating Temperature

 

+32°F to 104°F ( 0°C to 40°C )

 

Operating Relative

 

0 to 85% NON-CONDENSING

 

Humidity

 

 

 

 

 

 

 

Communication

 

 

 

 

 

PowerPanel® Personal

Windows2000/NT/XP/Server 2003/Vista/Mac OSX,Linux

Edition Software

 

 

 

 

 

Management

 

 

 

 

 

Auto-Charger

 

 

Yes

 

Auto-Restart

 

 

Yes

 

USB Interface

 

 

Yes

 

Other Features

 

 

 

 

 

Green Power

Yes (Energy saving technology)

 

Batter Charger

External AAA/AA battery charger, connection via USB charger

DEFINITIONS FOR ILLUMINATED LCD INDICATORS

LCD Indication

Line mode

Select SW

 

UPS Status Display

 

 

Capacity Display

 

Digital Value Display

 

 

 

 

 

 

 

 

 

 

 

 

 

Press

 

 

 

 

 

Load

Battery

Input

Output

Run

%

%

 

 

 

 

 

Cap.

Cap.

Voltage

Voltage

Time

of Load

of Batt.

 

 

 

 

 

 

 

 

 

 

 

 

 

Initial

V

X

--

X

 

V

X

 

V

 

 

 

1st

V

X

--

X

 

V

X

 

 

V

 

 

2nd

V

X

--

X

 

V

X

 

 

 

V

 

3rd

V

X

--

X

 

X

V

 

 

 

 

V

4th

V

X

--

X

 

V

X

V

 

 

 

 

5th(Return)

V

X

--

X

 

V

X

 

V

 

 

 

Press >3sec

V

X

V

X

 

--

--

--

--

--

--

--

(Sound Disable)

 

 

 

 

 

 

 

 

 

 

 

 

 

Press >3sec

 

 

 

 

 

 

 

 

 

 

 

 

again

V

X

X

X

 

--

--

--

--

--

--

--

(Sound Enable)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Overload)

V

X

--

V

 

--

--

--

--

--

--

--

“V” : Illuminated,

“X” : Not Illuminated,

“--“ : Either

 

 

 

 

 

 

 

Battery mode

Select SW

 

UPS Status Display

 

 

Capacity Display

 

Digital Value Display

 

 

 

 

 

 

 

 

 

 

 

 

 

Press

 

 

 

 

 

Load

Battery

Input

Output

Run

%

%

 

 

 

 

 

Cap.

Cap.

Voltage

Voltage

Time

of Load

of Batt.

 

 

 

 

 

 

 

 

 

 

 

 

 

Initial

X

V

--

X

 

X

V

 

V

 

 

 

1st

X

V

--

X

 

X

V

 

 

V

 

 

2nd

X

V

--

X

 

V

X

 

 

 

V

 

3rd

X

V

--

X

 

X

V

 

 

 

 

V

4th

X

V

--

X

 

X

V

V

 

 

 

 

5th(Return)

X

V

--

X

 

X

V

 

V

 

 

 

Press >3sec

X

V

V

X

 

--

--

--

--

--

--

--

(Sound Disable)

 

 

 

 

 

 

 

 

 

 

 

 

 

Press >3sec

 

 

 

 

 

 

 

 

 

 

 

 

again

X

V

X

X

 

--

--

--

--

--

--

--

(Sound Enable)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Overload)

X

V

--

V

 

--

--

--

--

--

--

--

“V” : Illuminated,

“X” : Not Illuminated,

“--“ : Either

 

 

 

 

 

 

 

For more information, visit eu.cyberpowersystems.com or contact

CyberPower Systems B.V.

Flight Forum 3545 5657DW Eindhoven The Netherlands

Tel: +31 40 2348170, E-MAIL: sales@cyberpower-eu.com

CyberPower Systems Inc. (USA) 4241 12th Avenue East Suite 400 Shakopee, MN 55379, U.S.A. Tel: +1 952 4039500, Fax: +1 952 4030009, E-MAIL: sales@cyberpowersystems.com

Entire contents copyright ©2008 CyberPower Systems B.V., All rights reserved. Reproduction in whole or in part without permission is prohibited. PowerPanel ® Personal Edition is the trademark of CyberPower Systems Inc.

CyberPower warrants to you, the original purchaser, that CyberPower UPS will be free from defects in design, assembly, materials and workmanship for two years ( battery is only one year) from the date of original purchase. Any warranty services, please contact your local dealers or distributors.

Page 2
Image 2
CyberPower Systems BR650ELCD Functional Test, AC Mode, On-Battery Mode, Routine Maintenance And Storage, Trouble Shooting