♦Rx (for BNC port).
◊Blinking: Packet reception is occurring.
◊OFF: No packet reception.
♦Partition (for each UTP port).
◊ON: The UTP port is being partitioned off due to excessive packet collisions. Note that the UTP cable between a hub port and a
◊OFF: Segment has no problem.
♦Partition (for BNC port).
◊ON: The BNC port is being partitioned off due to (1) no cable is connected, (2) faulty cable or connectors, (3) excessive packet collisions, (4) a disconnected point somewhere along the entire thin coaxial cable length, or (5) unterminated segment. Check all connectors along the cable length. If segment is not terminated, terminate both ends with
◊OFF: (1) Cable is connected and (2) segment has no problem.
♦Uplink
◊ON: The “9” UTP port is in the Uplink position (cross- wired).
◊OFF: The “9” UTP port is in the Normal position
16 | Installation |