DR30D

 

 

 

 

Document # PG05-006

 

 

 

 

 

 

Revised 10/01/10 Page 1/2

DistinctiveDual Fuel Range

PLANNING

GUIDE

 

 

 

 

 

 

 

All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.

 

 

 

 

warning

 

46 3/8” (117.8 cm)

 

Front of open door

 

 

 

 

 

Observe all governing codes and ordinances during

28 1/2” (72.4 cm)

 

Front of knobs

 

 

planning and installation. Contact your local building

26 1/2” (67.3 cm)

 

Front panel

 

 

department for further information.

 

24 3/8” (61.9 cm)

 

Rear of front panel/oven door

This appliance must be installed in accordance with

 

 

 

 

1 1/8” (2.9 cm)

 

 

 

 

the accompanying installation instructions.

9” (22.9 cm)

 

 

 

 

 

 

 

Backguard**

 

6” (15.2 cm)

 

 

 

 

 

 

 

3” (7.6 cm)

Backguard**

 

 

 

 

 

 

 

Backguard*

 

 

 

 

 

1 1/8” (2.9 mm) to cooking

 

 

 

 

 

 

 

 

surface (top of grates) from

 

 

* Standard

 

 

 

 

 

top of trim

 

** Optional

 

 

Gas

 

 

 

 

 

 

 

 

Width at front panel:

 

 

 

inlet

 

 

 

 

 

 

 

 

 

29 7/8” (75.9 cm)

 

35 3/4”

 

 

 

 

Range electrical access,

 

 

 

 

 

 

 

cover removed

 

 

 

(90.8 cm)

 

 

 

 

 

Finished side panel

 

to

 

 

B

 

 

 

 

 

37 7/8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(96.2 cm)

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

” (2.2 cm) dia. electrical

 

product Dimensions

 

 

 

 

7/8" to 1 1/8" dia. access hole

 

 

 

C

connection hole in bottom*

 

NOTE: This range is NOT designed for self-rimming installation or

 

 

 

Gas and Electrical Dimensions

installation with a raised vent.

 

 

 

 

 

 

 

 

Optional Backguard and Island Trim Part Numbers

 

 

 

Gas - Electrical Access Dimensions

 

 

A

 

B

C

D

Description

Part Number

 

 

 

 

 

 

 

 

Island trim kit (no backguard)

 

ADTK30

 

4 3/4”

 

22 1/8”

8 3/4”

13 3/4”

6 inch trim kit

 

ADB3006

 

(12.1 cm)

(56.2 cm)

(22.2 cm)

(34.9 cm)

 

 

 

 

 

 

 

9 inch trim kit

 

ADB3009

Ranges equipped for installation in Canada:

 

 

 

 

■■ Ranges equipped for use in Canada come pre-wired with a 4-wire,

 

 

 

 

66 inch (168 cm) long, appliance cord and NEMA 14-50P plug.

Gas Supply Pressure Requirements*
Gas Type
Manifold Pressure
Minimum Gas Supply

Pressure

 

 

Natural gas

5” water column

6” water column

LP

10” water column

11” water column

* Maximum input gas supply pressure for all models is 1/2 p.s.i.

The regulator inlet accommodates a 3/4” gas line. The range ships with a 1/2” to 3/4” adapter connected to the regulator.

Electrical Specifications
Circuit Required
Total Connected Load

240 Vac, 60 Hz., 30 Amp.*

5.7 kW (23.8 Amp.)

 

 

* Two 120 Vac hot (L1 and L2), one neutral, one ground

The ratings above are for reference only - refer to the range's product data label for exact specifications.

■■ Do not modify the factory wiring. The plug is designed to plug directly into a NEMA 14-50R electrical receptacle installed by a licensed electrician.

All other models:

The conduit or appliance cord installed needs to be long enough to allow the range to be pulled out from the wall for service, while remaining connected. See next page for further details.

The wiring to the range must:

Include a strain relief.

Be terminated by tinned leads, closed loop terminals or open ended spade lugs with upturned ends.

Where local code permits, a 3 or 4 wire appliance cord may be used. It must:

◊ Be UL listed type SRD or SRDT.

◊ Be equipped with a NEMA 14-50P 4-wire plug or, where local code permits, a NEMA 10-50P 3-wire plug.

 

 

5.14

Specifications subject to change without notice.

www.dacor.com