| DR30D |
|
|
|
| |||
Document # |
|
|
|
|
|
| Revised 10/01/10 Page 1/2 | ||
Distinctive™ Dual Fuel Range | PLANNING | ||||||||
GUIDE | |||||||||
|
|
|
|
|
|
| |||
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated. |
|
|
|
| warning |
| |||
46 3/8” (117.8 cm) |
| Front of open door |
|
|
|
| |||
| • | Observe all governing codes and ordinances during | |||||||
28 1/2” (72.4 cm) |
| Front of knobs | |||||||
|
| planning and installation. Contact your local building | |||||||
26 1/2” (67.3 cm) |
| Front panel |
|
| department for further information. |
| |||
24 3/8” (61.9 cm) |
| Rear of front panel/oven door | • | This appliance must be installed in accordance with | |||||
|
|
|
| ||||||
1 1/8” (2.9 cm) |
|
|
|
| the accompanying installation instructions. | ||||
9” (22.9 cm) |
|
|
|
|
|
|
| ||
Backguard** |
| 6” (15.2 cm) |
|
|
|
|
| ||
|
| 3” (7.6 cm) | Backguard** |
|
|
|
|
| |
|
| Backguard* |
|
|
|
|
| ||
1 1/8” (2.9 mm) to cooking |
|
|
|
|
|
|
|
| |
surface (top of grates) from |
|
| * Standard |
|
|
|
|
| |
top of trim |
| ** Optional |
|
| Gas |
|
| ||
|
|
|
|
|
| ||||
Width at front panel: |
|
|
| inlet |
|
| |||
|
|
|
|
|
|
| |||
29 7/8” (75.9 cm) |
| 35 3/4” |
|
|
|
| Range electrical access, |
| |
|
|
|
|
|
| cover removed |
| ||
|
| (90.8 cm) |
|
|
|
|
| ||
Finished side panel |
| to |
|
| B |
|
|
| |
|
| 37 7/8” |
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
| (96.2 cm) |
|
|
| D |
|
| |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| A | ” (2.2 cm) dia. electrical |
| |
product Dimensions |
|
|
|
| 7/8" to 1 1/8" dia. access hole | ||||
|
|
| C | connection hole in bottom* |
| ||||
NOTE: This range is NOT designed for |
|
|
| Gas and Electrical Dimensions | |||||
installation with a raised vent. |
|
|
|
|
|
|
|
| |
Optional Backguard and Island Trim Part Numbers |
|
|
| Gas - Electrical Access Dimensions |
| ||||
| A |
| B | C | D | ||||
Description | Part Number |
|
| ||||||
|
|
|
|
|
| ||||
Island trim kit (no backguard) |
| ADTK30 |
| 4 3/4” |
| 22 1/8” | 8 3/4” | 13 3/4” | |
6 inch trim kit |
| ADB3006 |
| (12.1 cm) | (56.2 cm) | (22.2 cm) | (34.9 cm) | ||
|
|
|
|
|
|
| |||
9 inch trim kit |
| ADB3009 | Ranges equipped for installation in Canada: |
| |||||
|
|
| ■■ Ranges equipped for use in Canada come | ||||||
|
|
|
| 66 inch (168 cm) long, appliance cord and NEMA |
Gas Supply Pressure Requirements*
Gas Type | Manifold Pressure | Minimum Gas Supply | |
Pressure | |||
|
| ||
Natural gas | 5” water column | 6” water column | |
LP | 10” water column | 11” water column |
* Maximum input gas supply pressure for all models is 1/2 p.s.i.
The regulator inlet accommodates a 3/4” gas line. The range ships with a 1/2” to 3/4” adapter connected to the regulator.
Electrical Specifications
Circuit Required | Total Connected Load |
240 Vac, 60 Hz., 30 Amp.* | 5.7 kW (23.8 Amp.) |
|
|
* Two 120 Vac hot (L1 and L2), one neutral, one ground
The ratings above are for reference only - refer to the range's product data label for exact specifications.
■■ Do not modify the factory wiring. The plug is designed to plug directly into a NEMA
All other models:
The conduit or appliance cord installed needs to be long enough to allow the range to be pulled out from the wall for service, while remaining connected. See next page for further details.
The wiring to the range must:
◊Include a strain relief.
◊Be terminated by tinned leads, closed loop terminals or open ended spade lugs with upturned ends.
Where local code permits, a 3 or 4 wire appliance cord may be used. It must:
◊ Be UL listed type SRD or SRDT.
◊ Be equipped with a NEMA
|
| 5.14 |